background image

3

10

SPECIAL APPLICATIONS HINDI 880

This page specifically refers to the special
operators in the Hindi 880 range, ie. drwg. No.
1990 - 150 mm, drwg. No. 0987 - 400 mm stroke
and drwg. No. 2552 braking in open/close cycles.
The detailed installation instructions that are
contained in this manual apply to all the models
in the Hindi 880 range.

Only, please note that the items 881 - 891 - 894,
that are non locking, have no manual release,
and an external electric lock is required to hold
the gates in the closed position. A temporary
connection to the control panel is to be provided
to drive out full movement of the shaft before
installation (manual test).

PISTON ASSEMBLY

PISTON

PISTON SHAFT

LONG SCREW

CYLINDER LINER

PISTON HEAD

ISOLA

TOR

COVER LONG SCREW

ADJUSTMENT NUT

BALL BEARING FRONT JOINT

COVER

COVER PLUG

FADINI OIL A 15 by AGIP

OIL-HYDRAULIC OPERATOR FOR SWINGING GATES. ABOVE GROUND

Two-way locking in “Open/Close” gate position

PIC. 1

1˙275

390

885

95

°

ADJUST THE SHAFT CONNECTION TO A
SUITABLE DISTANCE SO THAT THERE IS A 10
mn CLEARANCE BETWEEN THE COVER AND
THE GATE WHEN THE OPERATOR LINE IS IN
THE MOST CRITICAL POSITION, ie. ABOUT 60
DEGREES INCLINED TO THE GATE LINE. IN
MOST CASES THIS DISTANCE CAN BE
CONSIDERED TO BE INCLUDED BETWEEN 90
AND 100 mm, BUT THIS DISTANCE IS NOT
APPLICABLE TO ALL INSTALLATIONS.

GEOMETRY REQUIRED FOR THE MODEL 894 -
895 - 896

THE SUM OF 

A

 + 

B

 MUST TOTAL THE PISTON

STROKE.

210

A

95

°

GATE CLOSED

GATE STOP FIXED
TO THE GROUND

0

°

PIC.  20

COVER

MOST CRITICAL
INCLINATION

60

°

10 mm

GATE STOP FIXED
TO THE GROUND

95

°

B

180

GEOMETRY REQUIRED FOR THE MODEL 891 -
 892 - 893.

THE SUM OF 

A

 + 

B

 MUST TOTAL THE PISTON

STROKE.

750

140

610

60

A

B

80

95

°

PIC.  21

FRONT FIXING LONGER
BRACKET TO SUIT 400 mm RAM

Code 88073

Drwg. No. 0987

- 400 mm

Drwg. No. 1990

- 150 mm

t 19

t 8

t 8

t 14

STROKE 260

C = 27 s

A = 22 s

GATE STOP

130

B

A

D

740

260

1˙000

80

GATE
STOP

PIC. 22

with BRAKE
OPEN/CLOSE

- 280 mm

with BRAKE
OPEN/CLOSE

- 400 mm

ADJUST THE SHAFT CONNECTION TO A SUITABLE DISTANCE SO THAT THERE IS A 10 mm
CLEARANCE BETWEEN THE COVER AND THE GATE WHEN THE OPERATOR LINE IS IN THE
MOST CRITICAL POSITION, ie. ABOUT 60 DEGREES INCLINED TO THE GATE LINE. IN MOST
CASES THIS DISTANCE CAN BE CONSIDERED TO BE INCLUDED BETWEEN 90 AND 100
mm, BUT THIS DISTANCE IS NOT APPLICABLE TO ALL INSTALLATIONS.

GATE STOP

GATE STOP

PLEASE NOTE:
A VERY FINE ADJUSTEMENT IS REQUIRED
FOR BRAKING CONTROL OF THE OPERATOR

t 25

t 13

t 14

t 20

STROKE 385

C = 38 s

A = 34 s

160

B

A

120

220

885

1˙270

385

SPECIAL VERSIONS. BRAKING IN OPEN/CLOSE CYCLES  

(Drwg. No. 2552)

D

GATE CLOSED

GATE STOP FIXED
TO THE GROUND

GATE STOP FIXED
TO THE GROUND

Summary of Contents for HINDI 880 SPRINT

Page 1: ...This must be properly removed from the terminal board in the junction box Switch off the mains switch before removing the junction box cover where the electric cable of HINDI 880 is terminated All th...

Page 2: ...ULIC PISTON Time for one stroke 24 s Pump flow rate P5 1 4 l min Stroke 280 mm Cylinder bore 45 mm Piston shaft 20 mm Thrust power 3 000 Nm Working pressure 1 MPa 10 bars Max pressure 3 MPa 30 bars Oi...

Page 3: ...CAN BE CONSIDERED TO BE INCLUDED BETWEEN 90 AND 100 mm BUT THIS DISTANCE IS NOT APPLICABLE TO ALL INSTALLATIONS GEOMETRY REQUIRED FOR THE MODEL 894 895 896 THE SUM OF A B MUST TOTAL THE PISTON STROKE...

Page 4: ...ONNECTION DIAGRAM FOR SWING GATES ELPRO 13 exp INSTRUCTIONS FOR THE INSTALLATION OF HINDI 880 AN ELECTRO HYDRAULIC OPERATOR TWO WAY LOCKING IN OPEN AND CLOSE GATE POSITION 1 2 3 4 5 6 7 8 9 10 11 12 1...

Page 5: ...4 PIC 5 PIC 6 MANUAL RELEASE ANTI CLOCKWISE ONE COMPLETE TURN RELEASE TIGHTEN TO LOCK 1625 3rd OPERATION 1st OPERATION 2nd OPERATION DETAIL OF THE VALVE ENCLOSURE ALL THE VALVES ARE IN ONE BODY SPECI...

Page 6: ...The gate with the electric lock must open 5 degrees more than the other one REAR END BLOCK WITH FIXING PARTS RELEASE KEY REMOVABLE FOR EXTRA SECURITY REF No 1625 TWO WAY LOCKING DEVICE SAFETY PRESSURE...

Page 7: ...The gate with the electric lock must open 5 degrees more than the other one REAR END BLOCK WITH FIXING PARTS RELEASE KEY REMOVABLE FOR EXTRA SECURITY REF No 1625 TWO WAY LOCKING DEVICE SAFETY PRESSURE...

Page 8: ...4 PIC 5 PIC 6 MANUAL RELEASE ANTI CLOCKWISE ONE COMPLETE TURN RELEASE TIGHTEN TO LOCK 1625 3rd OPERATION 1st OPERATION 2nd OPERATION DETAIL OF THE VALVE ENCLOSURE ALL THE VALVES ARE IN ONE BODY SPECI...

Page 9: ...ONNECTION DIAGRAM FOR SWING GATES ELPRO 13 exp INSTRUCTIONS FOR THE INSTALLATION OF HINDI 880 AN ELECTRO HYDRAULIC OPERATOR TWO WAY LOCKING IN OPEN AND CLOSE GATE POSITION 1 2 3 4 5 6 7 8 9 10 11 12 1...

Page 10: ...CAN BE CONSIDERED TO BE INCLUDED BETWEEN 90 AND 100 mm BUT THIS DISTANCE IS NOT APPLICABLE TO ALL INSTALLATIONS GEOMETRY REQUIRED FOR THE MODEL 894 895 896 THE SUM OF A B MUST TOTAL THE PISTON STROKE...

Page 11: ...ULIC PISTON Time for one stroke 24 s Pump flow rate P5 1 4 l min Stroke 280 mm Cylinder bore 45 mm Piston shaft 20 mm Thrust power 3 000 Nm Working pressure 1 MPa 10 bars Max pressure 3 MPa 30 bars Oi...

Page 12: ...This must be properly removed from the terminal board in the junction box Switch off the mains switch before removing the junction box cover where the electric cable of HINDI 880 is terminated All th...

Reviews: