XL

 

ENG

  

Summary of Contents for Relaxed Premium XL

Page 1: ...Relaxed Premium XL 40010949 14xx Relaxed Premium XL ENG ...

Page 2: ...Installation Instructions 1 3 alternative finishes 1 1a 1 1b 1 1c ...

Page 3: ...Installation Instructions 2 1 2 1 3 1 4 7 ...

Page 4: ...Installation Instructions 3 1 9 1 5 1 6 B ...

Page 5: ...Installation Instructions 4 2 1 2 2 2 3 3 1 3 2 3 3 3 4 ...

Page 6: ...Installation Instructions 5 3 5 4 1 4 2 4 3 ...

Page 7: ...re and heating purposes This means that all surfaces including the glass can be very hot over 100 C exceptions to this are the bottom of the fire and the control elements Do not place any combustible materials within 0 5 m of the radiation area of the fire Light the fire for the first time and run for several hours on the highest setting so that the paint can cure Provide adequate ventilation so t...

Page 8: ...of Ø 100mm or Ø 130mm with CE marking for 600 C Please note The minimum chimney diameter for a 130mm flexible stainless steel pipe must 200 x 200mm And for a 100mm flexible stainless steel pipe 150x150mm 4 Preparation and installation instructions 4 1 Gas connection The gas connection must comply with the applicable local standards We advise using a Ø 15mm gas connection directly from the gas mete...

Page 9: ...assage of 200cm2 per grid or a similar alternative Place above the grates a screen plate made of non combustible material see Fig 1 9A 4 6 3 Installation and finishing For installation and finishing the following points are of interest A Fixing points Fig 1 2 B Mouldings Fig 1 2 C Spacer Fig 1 2 D F and H Fig 1 3 Please note Ensure that the fire is not load bearing with regard to the false chimney...

Page 10: ...bution is good Move the chips if necessary until a good flame distribution is achieved 7 Checking the installation 7 1 Checking the main burner ignition pilot flame Ignite the fire as described in the user manual Check that the pilot flame is well above the main burner and not covered by chips Check the ignition of the main burner on full and small setting ignition must be smooth and quiet 7 2 Che...

Page 11: ...lacing the batteries and setting the receiver Handover to customer o Installation instructions o User manual o ITC operating instructions o Log set instruction card o Suction Cups o Magnetic snapper 9 Annual maintenance 9 1 Checking and cleaning Check and clean if necessary after verification o The pilot light o The burner for LPG flat burner the ceramic burner top o The combustion chamber o The g...

Page 12: ...ts H J L M P and R Fig 12 1 end 12 2 Elbows 90 in the horizontal plane Horizontal bends are bends which are entirely in the horizontal plane Fig 12 1 12 2 and 12 3 I K and Q Bends 45 or 30 in the horizontal plane Horizontal bends are bends which are entirely in the horizontal plane Bends Elbows 90 vertical to horizontal plane These are 90 elbows which proceed from horizontal to vertical Fig 12 2 a...

Page 13: ...Installation Instructions 12 11 1 Table for pipe diameter 150 100mm Start Length STL Vertical TVH and Horizontal THL 11 2 STL TVH THL ...

Page 14: ...Installation Instructions 13 Table for pipe diameter 130 200mm Startlength STL Vertical TVH en Horizontal THL STL THL TVH ...

Page 15: ...Installation Instructions 14 12 Example Fig 12 1 Fig 12 2 Fig 12 3 ...

Page 16: ...Installation Instructions 15 13 Calculation Sheet ...

Page 17: ...Installation Instructions 16 ...

Page 18: ... 15ºC and 1013 mbar gr h 680 700 Burner pressure at full mark mbar 12 25 1 31 Injector main burner mm ST 510 7x0 83 ST 510 7x0 83 ST 180 7x0 50 ST 160 7x0 50 ST 180 7x0 50 ST 160 7x0 50 Reduced input restraint mm 1 8 1 4 1 4 Pilot assembly SIT 145 SIT 145 SIT 145 Code Injector Nr 36 Nr 23 Nr 23 Flue size mm 200 130 200 130 200 130 Gas control valve GV60 GV60 GV60 Gas connection 3 8 3 8 3 8 Electri...

Page 19: ... Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short roof termina...

Page 20: ...Installation Instructions 19 16 Dimensional drawings 16 1 Relaxed Premium L 348 Ext ...

Page 21: ...Installation Instructions 20 16 2 Ventilation grid and control door ...

Page 22: ...Installation Instructions 21 Dealer info ...