Faber NL-8448 CC Heerenveen Installation And Operating Instructions Manual Download Page 1

installation and operating instructions

electrical ambience heating

KOLDING

ELECTRIC

Saturnus 8

NL-8448 CC Heerenveen

Postbus 219

NL-8440 AE Heerenveen

T. +31(0)513 656500
F. +31(0)513 656501

40 010 5XX

0138

Summary of Contents for NL-8448 CC Heerenveen

Page 1: ...nstallation and operating instructions electrical ambience heating KOLDING ELECTRIC Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 40 010 5XX 0138 ...

Page 2: ...NSTALLATION GB 6 4 1 Dimensions GB 6 4 2 Location and Minimum Free Space GB 6 5 OPERATION GB 7 5 1 Operation GB 7 5 2 Flame effect GB 7 5 3 Heating unit GB 7 5 4 Thermostat operation GB 8 5 5 Thermal safety cut out GB 8 6 CLEANING AND MAINTENANCE GB 9 6 1 Cleaning GB 9 6 2 Lamp replacement GB 9 ...

Page 3: ... FOREWORD This fire incorporates a flame effect which can be used with or without heating so that comforting effect may be enjoyed at any time of the year The flame effect is provided by low wattage motors and three 40 Watt lamps Using the flame effect on its own therefore requires little electricity The controls are concealed behind the ashpan flap control cover A choice of 1000 W or 2000 W therm...

Page 4: ... stove The stove should also be disconnected from the power source before any repairs are carried out Altough this heater complies with safety standards we do not recommend its use on deep pile carpets or on long hair type of rugs 3 SAFETY PRECAUTIONS Ensure that all packaging items are removed read any warning labels carefully Please keep this manual for further reference Retain all packaging unt...

Page 5: ...to operate the heating switch L must be in the ON position see fig 2 Low Heat Setting With switch L in the ON position press switch to ON High Heat Setting With switches L and in the ON position press Switch to ON The 1800 W heat output is controlled by the thermostat which should be set to maximum see thermostat operation 4 INSTALLATION 4 1 Dimensions W x H x D 620 x 705 x 470 mm 4 2 Location and...

Page 6: ...e heater has cooled N No ot te e If the cut out continues to operate intermittently the heater should be switched off and a service agent contacted m in max econ fig 3 6 CLEANING AND MAINTENANCE Always disconnect from the power supply before attempting any maintenance 6 1 Cleaning Before commencing cleaning unplug the heater and allow it to cool The surface of the heater should be given an occasio...

Reviews: