5 <
<
<
<
L
Corners of the building.
Roof overhangs and balconies.
Eaves, with the exception of the roof ridge (See Capital 15).
3.5
Existing chimney
You can also connect the appliance to an existing chimney. The existing chimney will
function as an air supply and a flexible stainless steel pipe drawn up through the chimney
will remove the combustion gas.
The flexible stainless steel pipe of Ø100mm should have a CE mark for temperatures up to
600
°
Celsius.
The chimney should comply with the following requirements:
The diameter of the flue system must be at least 150x150mm.
There should be no more than 1 appliance connected to a flue pipe.
The chimney must be in good condition:
o
No leakage and
o
It should be properly swept.
For more information about connections to existing flue systems, see the manual
“connections”.
4
Preparation and Installation instructions
4.1
Gas connection
The gas connection must comply with locally valid standards.
We advise Pipe work from the meter to the appliance must be of adequate size, with near
the appliance a gas isolator tap that should always be accessible. Place the gas connection
in such a way that this is easily accessible and that before service, the burner unit can be
disconnected at all times.
4.2
Electric connection
If an adapter is used for the power supply, then a wall socket 230VAC – 50Hz must be
mounted in the vicinity of the hearth.
4.3
Preparation of the appliance
Remove the packaging of the appliance. Make sure the gas pipes underneath the
appliance are not damaged.
Summary of Contents for Fyn 450
Page 1: ...Fyn 450 40010929 1840 Fyn 450 ENG ...
Page 2: ...1 L 1 1 1 2 1 3 1 4 1 5 1 6 2 1 2 2 2 3 ...
Page 3: ...2 L 3 1 3 2 4 0 4 1 4 2 4 3 4 4 ...
Page 15: ...14 L 12 Examples flue materials Fig 12 1 Fig 12 2 Fig 12 3 ...
Page 21: ...20 L 16Troubleshooting guide ...
Page 22: ...21 L YES ...
Page 23: ...22 L YES YES ...
Page 24: ...23 L ...
Page 25: ...24 L ...
Page 26: ...25 L 17Dimensional drawings 17 1 Fyn 450 ...
Page 27: ...26 L 17 2 Ventilation grid ...
Page 28: ...27 L 17 3 Remote access door ...
Page 29: ...28 L ...
Page 30: ...29 L ...
Page 31: ...Fyn 450 ...