LED-SIGNALS

The ORANGE LED 
fl ashes 1 x 
every 3 seconds.

Bad adjustment

The ORANGE LED is 
on permanently.

The ORANGE LED 
fl ashes quickly.

The RED or GREEN 
LED is ON sporadicly. 

Check if the DIP-switch 4 is ON (uncovered zone).
Launch a calibration.

Send the sensor back for a technical check-up.

Corfi rm the DIP-switch setting: 
long push on the push button.

Cut and restore power supply.
If orange LED fl ashes again, replace sensor.

The sensor does not 
react, but a calibration 
can be launched.

Chech wiring. 
- Door control with test: 
  Connect RED and BLUE wires to test output.
- Door control without test: 
  Connect RED to 0 V and BLUE to +12 V - 30 V DC.

The ORANGE LED 
fl ashes 2 x 
every 3 seconds.

The ORANGE LED 
fl ashes 3 x 
every 3 seconds.

The ORANGE LED 
fl ashes 4 x 
every 3 seconds.

The ORANGE LED 
fl ashes 5 x 
every 3 seconds.

Check power supply (tension, capacity).
Reduce the cable length or change cable.

Check wiring between modules.
Launch a module count: long push on push button 
of MASTER.

Launch a new calibration. 
Step out of the detection fi eld.
Change angle of spots.
Switch off background (DIP 3: OFF).

Launch a new calibration.

Power supply is out of limit.

The sensor signals an 
internal fault.

Bad adjustment of the 
uncovered zone.

The monitoring is activated, 
but the test input is not 
powered.

Communication error 
between modules.

The sensor receives 
not enough IR-energy.

The sensor receives too 
much IR-energy.

The sensor encounters 
a memory problem.

DIP-switch setting 
awaiting confi rmation.

The RED or 
GREEN LED is ON 
permanently. 

The ORANGE LED 
fl ickers.

The sensor is disturbed by 
lamps or another sensor.

Select a different frequecy for each module (DIP 2).
Launch a new calibration.

Calibration error

Check mounting height.
Change position of calibration screw. 
Launch a new calibration.

Check if the DIP-switch 4 is ON (uncovered zone).
Launch a calibration.

BEA hereby declares that the FAAC XPB34-1/70-1/90-1/90-2 ON is in conformity with the basic requirements and the other 
relevant provisions of the directives 2004/108/EC and 2006/42/EC.
Notifi ed Body for EC inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
Angleur, May 2013 

Pierre Gardier, Authorized representative

Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)

SAFETY INSTRUCTIONS

The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable 
national and international regulations and standards on door safety and if applicable, the machinery directive 2006/42/EC. 
Only trained and qualifi ed personnel may install and setup the sensor. 
The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel. 
Avoid touching any electronic and optical components.

XPB34-1/70-1 ON
XPB90-1/90-2 ON

1

2

3

4

5

6

7

8
9

10

11

E

R

L

A

U

B

T

 

Z

E

R

T I

F I

Z I E R U N G

 

N

A

C

H

DIN 1

865

0

E

N

A

B L

E S

 

A C C

O

R

D

A

N

C

E

 

W

I

T

H

TECHNICAL SPECIFICATIONS

1. profi le
2. supporting 

clip

3. main 

connector

4. DIP-switch
5. calibration 

screw

6. receiver

DESCRIPTION

ENGLISH

Safety sensors 
for automatic swing doors

7. end 

cap

8. 

clip with angle adjustment screw

9. transmitter 

(TX)

10. push 

button

11. front 

face

active infrared with background suppression
400 mm (W) x 70 mm (D) (at 2 m mounting height; 4 spots active)
1.1 m to 3 m (according to fl oor refl ectivity)
64 ms (typ)
infi nite
12 V - 24 V AC +/-10% ; 12 V - 30 V DC -5%/+10%

(to be operated from SELV compatible power supplies only)

110 mA @ 24 V AC/ 70 mA @ 24 V DC; 190 mA @ 12 V AC/ 145 mA @ 12 V DC (MASTER)
85 mA @ 24 V AC/ 60 mA @ 24 V DC; 180 mA @ 12 V AC/ 113 mA @ 12 V DC (other modules)
2 relays (free of potential contact)
42 V AC/DC
1 A (resistive)
30 W (DC) / 60 VA (AC)
1 optocoupler (free of potential contact)
30 V
high: >10 V DC; low: <1 V DC
4 (up to 6 if 24 V DC)
min. 5% at IR-wavelength of 850 nm
IP53
-25 °C to +55 °C; 0-95% relative humidity, non condensing
5 years
EMC 2004/108/EC; MD 2006/42/EC; EN 12978
EN ISO 13849-1:2008 Performance Level «c» CAT. 2

 

(under the condition that the door control system monitors the sensor at least once per door cycle)

Technology:
Detection fi eld:  
Mounting height:
Reaction time:
Max. presence time:
Supply voltage:

Max current consumption:

Output: 
   Max. contact voltage
   Max. contact current
   Max. switching power
Input:
   Max. contact voltage:
   Voltage threshold:
Max. number of modules:
Refl ectivity:
Degree of protection:
Temperature range:
Expected lifetime:
Norm conformity:

Other use of the device is outside the permitted purpose 
and can not be guaranteed by the manufacturer.
The manufacturer cannot be held responsible for incorrect 
installations or inappropriate adjustments of the sensor.

For pr

oduct version 0100 and mor

e

Please keep for further use
Designed for colour printing

Specifi cations are subject to changes without prior notice.

All values measured in optimal conditions.