11.2 CYCLE COUNTER
READING THE CYCLES PERFORMED COUNTER
Add together the readings of functions
nc
(thou-
sands) and
nd
(tens) in ADVANCED programming.
RESETTING THE CYCLE COUNTER
In ADVANCED programming, with the function
AS
=
no
, go to function
nc
and press
++
and
--
for 5 s
.
11.3 MAINTENANCE REQUESTED
It is possible to program the number of cycles after
which maintenance is required.
When the automation reaches the set number of
cycles, there is a pre-flashing of at least 8 s at each
movement. The user should ask the installer to carry
out maintenance.
1. In ADVANCED programming, function
AS
, se-
lect
Y
to enable the maintenance request.
2. In function
nc
set the value in thousands using
the
++
and
--
buttons.
3. In function
nd
set the value in tens using the
++
and
--
buttons.
4. Exit and save the programming.
11.4 BUFFER BATTERY
The battery (model CR2032) is required if
Simply Connectmodules are installed.
It should be replaced with the power disconnected.
Insert the batteries in the direction shown.
Summary of Contents for E145S