6. ELECTRONIC INSTALLATION
RISKS
PERSONAL PROTECTIVE EQUIPMENT
F
ALWAYS DISCONNECT THE POWER SUPPLY before
working on the board. Turn power on only after
having made all the electrical connections and carried
out the preliminary start-up checks.
The board cover must never be removed unless the
board is to be replaced. No installation operation
requires the removal of the cover.
6.1 BOARD E614
7
E614 board technical data
230V~
115V~
Power supply voltage
220-240 V~ 50/60 Hz
115V~ +/-10% 50/60 Hz
Max power
150 W
150 W
Accessories output voltage
24 V
"
24 V
"
Max. accessories load
500 mA
500 mA
Max. BUS 2easy accessories load
500 mA
500 mA
Max. flashing light load
24 V
"
15 W
24 V
"
15 W
Ambient operating temperature
-20 °C to +55 °C
-20 °C to +55 °C
COMPONENTS
See figure
BOARD:
J1
Mains power supply terminal board
J3
BUS 2easy terminal board
J6
Accessory/input terminal board
J7
Connector for XF radio module
J8
Connector for XBAT 24 battery
J10
Terminal board for external detector LOOP1
J11
Connector for encoder
J13
Terminal board for external detector LOOP2
J16
Terminal board for external flashing light
J18
Terminal board for the beam lights
J20
Terminal board for outputs
J21
Connector for integrated flasher
J23
Connector for motor
F3
Board protection fuse (F3 = T2.5A)
DISPLAY
Programming display
BOARD:
DL1
Device signalling LED to BUS 2easy ACTIVE
DL2
BUS 2easy “BUS MON“ diagnostic signalling LED
DL3
“RADIO1” (OMNIDEC) signalling LED
DL4
“RADIO2” (OMNIDEC) signalling LED
DL5
Error/alarm signalling LED
DL8
EMER status LED
DL9
STOP/FSW-CL status LED
DL10
CLOSE status LED
DL11
OPEN status LED
DL12
LOOP1 status LED
DL13
LOOP2 status LED