ATR833A-II / P/N 833-II (Axxx)-(Axxx)
Operation and Installation
Doc.-No. 01.143A.010.71e / Revision 1.00
42
4.7.3 Wiring with Cable Harness BSKS833x-S
4.7.3.1 Overview / Variants of cable sets
Five different cable sets are available for a wide range of applications
BSKS833S-S
Basic cable-set for single-seater
BSKS833D-S
Basic cable-set for double-seater
BSKS833OE-S
Cable-set for double seats (powered aircraft)
with open ends
BSKS833GLS-S
Cable-set
for
single-seater
(glider)
with open ends
BSKS833GLD-S
Cable-set
for
double-seater
(glider)
with open ends
You will find a detailed description of the cable variants, such as the
corresponding cable diagram, in document Doc. No. 01.14x.050.50 on
our homepage under
Service / info download / radios
4.7.3.2 Connector D-SUB DE-9 Female for Remote Control
This connector contains the serial interface and the power supplies for
the remote control unit.
The remote control interface is a serial RX-TX interface with RS232
voltage levels with 9600 baud, 8 data bits, no parity, 1 stop bit, no
handshake.
Each message begins with 2 byte sequences 0x02 (STX) and 0x72 ('r')
for synchronization followed by a message identification-byte and a
different number of data bytes.
Connector for the Remote
Control in the cable
harness BSKS833D-S
View from
aircraft’s side
1: not connected
2: Data TX
3: Data RX
5: GND shielding
8: +5VDC