12
by the display: real-time speed, total mileage (ODO), single-mile (Trip), riding time (Time), maximum speed
(MAX SPEED), average speed (AVG SPEED), power-assisted gear, power, error code mode.
The current speed display, the speed display unit has two types of display: mile display and kilometer display,
which can be set in the settings. The actual instrument speed is displayed in only one unit. It is not possible
to have two units at the same time.
The total mileage, single mileage, riding time, maximum speed and average speed can be switched and
displayed. In the power-on state, the above functions can be switched, and the display power-on defaults to
the interface before the last shutdown. To switch, press the key for 0.5 seconds to enter the switch display
selection of ODO->TRIP->TIME->MAX->AVG->ODO cycle.
Battery Capacity
When the battery is fully charged, the 5 bar are fully illuminated; when the battery is under voltage, the last
cell will flash and need to be charge
immediately, as shown below:
Battery Capacity
5%
——
25%
1
st
Bar
25%
——
45%
2
nd
Bar
45%
——
65%
3
rd
Bar
65%
——
85%
4
th
Bar
85%
——
100% 5
th
Bar
Error Code
When the Ebike control system fails, the display will automatically show an error code and the error code
will flash. And stop normal work, only when the fault is eliminated can exit the fault display interface (even
if the display is turned off without troubleshooting, the display will not work normally after restarting the
display), the error code list is detailed in the attached error code definition table.
Reset
In the power-on state, press the plus and minus keys for more than 3 seconds on any interface, and the
information in the TRIP, TIME, MAX, AVG interface will reset to zero.
Password
In the main interface and the speed is 0, press and hold the key for 10 seconds to enter the password input
interface of the setting mode. Short press the plus key to switch from 0->1->2->3->4->5->6->7->8->9->0
cycle; short press the down key to make the digits Left->Right->Left cycle switching selection, after setting
the four-digit password (fixed password 6262), press the key for 0.5 seconds. If the password is correct,
enter the menu selection interface immediately.
If the password is incorrect, return to the main immediately. After entering the correct password every
time, the power is turned on, the next time you enter the password input interface, the meter will display
the password that was correctly entered last time. Unless the password entered last time is incorrect or
the power is turned off, you need to re-enter the correct password