2-2
Specification
Product name
Model
Convection system
Range of temperature
control
Accuracy of temperature
control
※
1
Range of
temperature
distribution
※
1
Temperature
control
Temperature sensor
Setting temperature
・
display
Heater
F
e
a
t
u
r
e
s
C
o
m
p
o
n
e
n
t
Low temperature incubator
LTI-400E
Air jacket natural convection system
4
〜
60
℃
Minimum digit 0.1
℃
・
Cont. mode
(
Heater P.I.D control
+
Continuous operation of refrigeration unit
)
・
Int. mode
(
Heater P.I.D control
+
Continuous operation of refrigeration unit
+
hot
gas
)
Platinum Thermo resistance
Pt100Ω
Sheet key input
・
digital display
F
u
n
c
t
i
o
n
s
Defrosting system
※
2
Safety features
-2-
LTI-700E
LTI-1200E
Capacity of the chamber
Shelf
Dimension of shelf
(
mm
)
Cable port
Anti-bacterial stainless steel board
(
Partially
)
2 points
(
right and left side
)
Bore diameter: 40
mm
Dimension of the chamber
(
mm
)※
3
Dimensions
(
mm
)
※
3
Supply power
※
4
Supply voltage
Mass
S
p
e
c
i
f
i
c
a
t
i
o
n
s
Approx. 90
L
500(W)
×
400(D)
×
450(H)
5
〜
35
℃
630(W)
×
685(D)
×
1185(H)
9A 0.9kVA
AC100V 50/60Hz
Approx.85
㎏
Uniformly-distributed load
Max.15kg/shelf
Supplied shelves: 2 piece
Supplied shelves:5 shelves
468(W)
×
375(D)
Shelf pitch
・
number of
step
40mm
・
4 steps
×
2 points
40mm
・
5 steps
×
4 points
Bath
Range of temperature range
・
±
0.2
℃
(
in Cont.mode
)
・
±
1.0
℃
(
in Int. mode
)
・
2.0
℃
(
Cont.mode Setting value:
20
〜
37
℃
)
・
3.0
℃
(
Cont. mode Setting value:4
℃)
・
4.0
℃
(
Int. mode Setting value:20
〜
37
℃)
・
5.0
℃
(
Int. mode Setting value:4
℃)
・
Normal operation
:
Microcomputer automatic control
(
Int. mode
)
・
Forced manual system
(
manual initiation, automatic termination, manual
Program function
Automatic stop, automatic start, 1-step, 24-hour cycle operation
Stainless heater 550W
Stainless heater
700W
Refrigeration unit
・
refrigerant
Air-cooled type
160W
・
R-134a
Air-cooled type
300W
・
R-134a
600(W)
×
500(D)
×
1000(H)
Approx.300
L
Door
Both sides can be opened.
630(W)
×
705(D)
×
900(H)
Approx.98
㎏
Approx.145
㎏
13A 1.3kVA
Residual current device, over heat protecting thermostat door switch, individual over heat protector
(temperature range: 30-70
℃
), individual overcool protector (temperature range: 0-40
℃
), self-diagnosis
function for temperature controller (sensor, door, upper / lower temperature limit , abnormal temperature
control, power failure, watchdog) , over load relay protective circuit for refrigeration unit, protection timer for
refrigeration unit, fuse for outlet
Temp
Air-cooled type
200W
・
R-134a
500(W)
×
400(D)
×
700(H)
Approx. 140
L
Supplied shelves:3 pieces
568(W)
×
455(D)
40mm
・
7 steps
×
2 points
Inner door
Both sides can be opened.
Acryl
(
1 piece
)
Both sides can be opened.
Acryl
(
2 piece
)
Service outlet
Clamp for fixing the
product
Diameter of port:
7
・
12mm
2 outlets in the chamber
(
1A
・
2A)
1 chamber outside of the chamber
(
2A)
2 outlets in the chamber
(
1A
・
2A)
1 outlet in the chamber
(
2A)
740(W)
×
815(D)
×
1600(H)
11A 1.1kVA
Fan in the chamber
Axial current fan
(
Forced circulation system
)
Tempera
・
2.0
℃
(
Cont.mode
Setting temp.: 20
〜
37
℃)
・
4.0
℃
(
Cont.Mode
Setting temp.:4
℃)
・
4.0
℃
(
Int.Mode
Setting temp.:20
〜
37
℃)
・
5.0
℃
(
Int. Mode
Setting temp.:4
℃)
・
2.0
℃
(
Cont.mode
Setting temp.: 20
〜
37
℃)
・
5.0
℃
(
Cont.Mode
Setting temp.:4
℃)
・
4.0
℃
(
Int.Mode
Setting temp.:20
〜
37
℃)
・
6.0
℃
(
Int. Mode
Setting temp.:4
℃)