XTP T USW 103 Switcher • Installation
9
Cable recommendations
Extron recommends using the following practices for XTP communication to achieve full
transmission distances up to 330 feet (100 meters) and reduce transmission errors.
•
Use the following Extron XTP DTP 24 SF/UTP cables and connectors for the best
performance:
•
XTP DTP 24/1000
Non-Plenum 1000’ (305 m) spool
22-236-03
•
XTP DTP 24P/1000
Plenum 1000’ (305 m) spool
22-235-03
•
XTP DTP 24 Plug
Package of 10
101-005-02
•
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
•
Terminate cables with shielded connectors to the TIA/EIA-T568B standard (see
on the previous page).
•
Limit the use of more than two pass-through points, which may include patch points,
punch down connectors, couplers, and power injectors. If these pass-through points
are required, use shielded couplers and punch down connectors.
NOTE:
When using STP cable in bundles or conduits, consider the following:
•
Do not exceed 40% fill capacity in conduits.
•
Do not comb the cable for the first 20 m, where cables are straightened, aligned,
and secured in tight bundles.
•
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
•
Separate twisted pair cables from AC power cables.
Contact Closure Communication
Each port senses an external switch or contact closure. Use these ports to select an input
on the switcher from a contact closure device. Wire the connector as shown in figure 7.
CONTACT
1 2 3 G
Ground
Wire Nut
Device 3
Device 2
Device 1
(Switches,
relays, or
similar items)
Switch
1
2
3
G
Heat
Shrink
Over
Shield
Wires
Figure 7.
Wiring the Contact Closure Connector