Run or Stop Events
This mode is used for troubleshooting.
Activation
To start the Run/Stop Events reset mode:
1.
Press and hold the
Reset
button until the Power LED blinks once (after 3 seconds).
2.
Release and press
Reset
momentarily (for <1 second) within 1 second. Nothing happens if
the momentary press does not occur within 1 second.
Result
Events are toggled on and off.
Reset All IP Settings
This mode resets all IP settings to factory defaults. It enables IP address information to be reset
using ARP and the MAC address.
Activation
To reset all IP settings:
1.
Hold down the
Reset
button for about 6 seconds until the Power LED blinks twice (once at
3 seconds and again at 6 seconds).
2.
Release and press
Reset
momentarily (for <1 second) within 1 second. Nothing happens if
the momentary press does not occur within 1 second.
Result
Reset All IP Settings mode:
•
Enables ARP capability.
•
Sets the IP address back to factory default (
192.168.254.251
).
•
Sets the subnet back to factory default (
255.255.0.0
).
•
Sets the default gateway address to the factory default (
0.0.0.0
).
•
Sets port mapping back to factory default.
•
Turns DHCP off.
•
Turns events off.
Reset to Factory Defaults
This mode resets all IP settings and touchpanel settings to factory defaults and removes all
configurations. It allows you to start over with configuration and uploading and to replace events.
Activation
To reset the unit to all factory default settings:
1.
Hold down the
Reset
button for about 9 seconds until the Power LED blinks three times
(once at 3 seconds, again at 6 seconds, and again at 9 seconds).
2.
Release and press
Reset
momentarily (for <1 second) within 1 second. Nothing happens if
the momentary press does not occur within 1 second.
TLP 350CV and TLE 350 • Reference Material