Connecting a Two-position Switch to the Digital Input Port
+5.0 V
1k ohm
SW 2
Two-position
Switch
Digital
Input
GND
Voltage
Protection
CTL
Figure 8.
Connecting a Two-position Switch to the Digital Input Port
•
Port Configured
— Input with pull‑up (switch 2 closed)
•
Two Position Switch Open
— Digital input reads +5 VDC = Logic High
•
Two Position Switch Closed
— Digital Input reads 0 VDC = Logic Low
Control Ports — USB Adapter
IR Port
Insert the wires from an IR Emitter into the IR port and place the head of the emitter over or next
to the IR signal pickup window of the device being controlled.
Connect two wires to the IR port, as shown in figure 9. If both the IR port and contact closure
port are used, the ground pin must be shared by both devices.
NOTE:
Each emitter must be within 100 feet (30.4 meters) of the TLC control system for
best IR control results.
SG
IN
IR/C IN
To the IR Receiver of a
Projector, Display, or
Source Device
S
G
(-)
(+)
(-)
(+)
(+)
(-)
Two Single IR Emitters
Ground
IR Output Signal
Unidirectional
IR
Figure 9.
IR Connector
The IR port can accept a single IR emitter (see figure 10, top), a dual IR emitter (center) or two
single IR emitters, tied in series (bottom).
Ground (−)
IR Signal (+)
Ground (−)
IR Signal (+)
(+)
(−)
(−)
(+)
IR Signal (+)
Ground (−)
One Single IR Emitter
Dual IR Emitter
Two Single IR Emitters
Figure 10.
IR Emitter Configurations
TLC Pro 526M, 726M, and 1026M Series TouchLink Pro Control Systems • Panel Features
13