background image

 

4

68-2294-50 Rev. A

08 15

Extron Headquarters

+1.800.633.9876 (Inside USA/Canada Only)

Extron USA - West

 

Extron USA - East

+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX 

+1.919.850.1001 FAX

Extron Europe

+800.3987.6673 

(Inside Europe Only)
+31.33.453.4040
+31.33.453.4050 FAX

Extron Asia

+65.6383.4400
+65.6383.4664 FAX

Extron Japan

+81.3.3511.7655
+81.3.3511.7656 FAX

Extron China

+86.21.3760.1568
+86.21.3760.1566 FAX

Extron Middle East

+971.4.299.1800
+971.4.299.1880 FAX

Extron Korea

+82.2.3444.1571
+82.2.3444.1575 FAX

Extron India

1800.3070.3777 

(Inside India Only)
+91.80.3055.3777
+91.80.3055.3737 FAX

              © 2015 Extron Electronics   All rights reserved. All trademarks mentioned are the property of their respective owners.  

www.extron.com

TLP Pro 1220TG and TLP Pro 1520TG • Setup Guide (Continued)

A

 

Power supply input

 (see 

figure 5

) — connect a 12 VDC, 3.0 A power supply (not provided) to this DC plug connector.

ATTENTION:

• 

The touchpanels can use a 12 VDC desktop power supply and are also Power over Ethernet (PoE Plus IEEE 
802.3at) compliant. Do not connect either power supply before reading the Attention in the Power section of the 

TLP Pro 1220 Series and TLP Pro 1520 Series User Guide

.

• 

Les écrans tactiles peuvent utiliser une source d’alimentation externe 12 Vcc, et sont également compatible avec 
l’alimentation POE via Ethernet (PoE Plus IEEE 802.3at). Ne branchez pas de sources d’alimentation externes avant 
d’avoir lu les mises en garde dans la section « Power Supply » du  

TLP Pro 1220 Series and TLP Pro 1520 Series 

User Guide

.

NOTE:

  The TLP Pro 1220TG and TLP Pro 1520TG are shipped without a power supply. Either the 12 VDC, 3.0 A power 

supply or the power injector must be purchased separately.

B

 

USB connectors

 (see 

figure 5

) — for peripheral controls.

C

 

Rear status light

 (see 

figure 5

) — an LED light bar that can be programmed to provide system feedback.

D

 

HDMI input

 (see 

figure 5

) — for alternative video input.

E

 

XTP/LAN/PoE input

 (see 

figure 5

) — is in the top of the recessed area. 

XTP

 input — Connect the touchpanel to the XTP source using a twisted pair cable, 

terminated with an RJ‑45 connector.

LAN

 input — Connect the touchpanel to the LAN using a twisted pair cable, 

terminated with an RJ‑45 connector.

PoE

 input — the connector can be used with a PoE plus power injector (not 

provided). Connect the cables as shown in the figure to the right, which shows the 
Extron PI 140 power injector (recommended by Extron).

An Extron IP Link Pro control processor must also be connected to the same network as the TouchLink Pro touchpanel.

F

 

Audio output

 (see 

figure 5

) — for use with headphones or assistive listening devices.

G

 

Menu button

 (see 

figure 5

) — activates the setup menu and calibration screen (see below). 

H

 

Reset button

 (see 

figure 5

) —  pressing the reset button allows the unit to be reset in any of three different modes. For full 

information about the modes, see the 

TLP Pro 1220 Series and TLP Pro 1520 Series User Guide

.

I

 

Reset LED

 (see 

figure 5

) — provides feedback about the reset status when the user presses the reset button.

J

 

VESA mounting holes (4)

 (see 

figure 5

) — for use with D‑type VESA mounting kits with the 100 x 100 mm mounting pattern.

K

 

Base attachment hinge

 (2) (see 

figure 5

) — each hinge secures the touchpanel to the base with two screws.

Reset Modes: a Brief Summary

The TLP Pro 1220TG and TLP Pro 1520TG offer the following reset modes:

• 

Use factory firmware:

Press and hold the 

Reset

 button (

figure 5

H

) while applying power to the unit. Use this mode 

to replace firmware in the event of firmware failure.

• 

Reset All IP Settings:

Press and hold the 

Reset

 button for 6 seconds. After the Reset LED (

figure 5

I

) flashes 

twice, release and momentarily press the 

Reset

 button. Use this mode to reset all network 

settings without affecting user‑loaded files.

• 

Reset to Factory Defaults:

Press and hold the 

Reset

 button for 9 seconds. After the Reset LED flashes three times, 

release and momentarily press the 

Reset

 button. Use this mode to return the interface to 

factory default settings.

Setup Menu

Press the menu button (

figure 5

G

) to open the setup menu. Select any 

of the five available screens (

Status

Network

Display

Audio

Input

 and 

Advanced

) by pressing the appropriate button in the navigation bar at the 

top of the screen (for more information, see the 

TLP Pro 1220 Series and 

TLP Pro 1520 Series User Guide

).

Figure 6 shows the setup menu for the TLP Pro 1220TG. The setup menu 
for the TLP Pro 1520TG is identical.
Press the menu button for at least 3 seconds to open the calibration 
screen. Follow the on‑screen instructions.

Figure 6. 

Setup Menu: Status page for TLP Pro 1220TG

Info

Model:

TLP Pro 1220TG

Part Number: 60-1341-02
Firmware

Version:

1.02.0000.b003

PoE:

Active

Network

IP Address:
DHCP:
Host Name:

Off

192.168.254.251

TLI-AB-CD-EF

Display

Resolution:
Project:
Sleep Timer:

1280x800
1280x800
5 Minutes

Audio

Master Volume:
Master Mute:

Off

100

Input

HDMI:

No Signal

Status

Display

Audio

Advanced

Exit

Network

Input

Advanced

Controller IP:

192.168.254.250

Project Size:

1/197 MB

Bootloader

Version:

1.03.0000

XTP:

1280x720

HDCP

100-240V~50/60 Hz

1.1A MAX

INPUT

OUTPUT

POWERED TLP

LAN

To Network or 
XTP Device

To a TLP Pro
touchpanel

Extron PI 140

Reviews: