background image

Network

Verify with your network administrator whether the IP address for the touchpanel is assigned by 
Dynamic Host Configuration Protocol (DHCP) or set manually. If they are set manually, you need 
to obtain an IP address, a subnet mask, a gateway address, and a Domain Name Server (DNS) 
from the network administrator.
Press the 

Network

 button in the navigation panel at the top of the screen to open the 

Network

 

screen.

Status

Display

Audio

Advanced

Exit

Network

DHCP

On

Off

Host Name:

DNS Primary:

IP Address:

Subnet Mask:

Domain Name:

Gateway:

MAC Address:

TLP-AB-CD-EF

192.168.254.251

255.255.255.0

0.0.0.0

00-05-A6-AB-CD-EF

Revert

Apply

127.0.0.1

Figure 6. 

Network Screen

1. 

If IP addresses are assigned by DHCP, press 

On

. The selected button is highlighted in 

yellow. If DHCP is selected, you can set only the Host Name and the DNS IP address. All 
other values are set by the DHCP server.

If IP addresses are assigned manually, press 

Off

. When DHCP is Off, all values can be 

edited.

2. 

Edit the 

Host Name

 by pressing that button. A keypad opens:

Figure 7. 

Alphanumeric Keypad

• 

Use the keypad to enter a new name, which appears in the 

Host Name

 text box.

• 

Use the backspace character ( 

x

 ) to delete existing characters.

• 

The right and left arrows move the cursor inside the 

Host Name

 text box.

• 

Click the 

Shift

 key to toggle between upper and lower case letters.

• 

Press 

Enter

 to save the new name.

 

TLP Pro 1022 Series • On-screen Menus

9

Summary of Contents for TLP Pro 1022T

Page 1: ...68 2405 02 Rev A 07 16 TLP Pro 1022 Series User Guide TouchLink TouchLink Pro Touchpanel Control Systems ...

Page 2: ...ent dans la documentation fournie avec le matériel Pour en savoir plus sur les règles de sécurité la conformité à la réglementation la compatibilité EMI EMF l accessibilité et autres sujets connexes lisez les informations de sécurité et de conformité Extron réf 68 290 01 sur le site Extron www extron com Istruzioni di sicurezza Italiano AVVERTENZA Il simbolo D se usato sul prodotto serve ad avvert...

Page 3: ... marks SM and trademarks TM are the property of RGB Systems Inc or Extron Electronics see the current list of trademarks on the Terms of Use page at www extron com Registered Trademarks AVTrac Cable Cubby CrossPoint DTP eBUS EDID Manager EDID Minder Extron Flat Field FlexOS GlobalViewer Global Configurator Hideaway Inline IP Intercom IP Link Key Minder LinkLicense LockIt MediaLink MediaPort NetPA ...

Page 4: ...is interference must be corrected at the expense of the user NOTE For more information on safety guidelines regulatory compliances EMI EMF compatibility accessibility and related topics see the Extron Safety and Regulatory Compliance Guide on the Extron website Battery Notice This product contains a battery Do not open the unit to replace the battery If the battery needs replacing return the entir...

Page 5: ...computer or device responses mentioned in this guide the character 0 is used for the number zero and O represents the capital letter o Computer responses and directory paths that do not have variables are written in the font shown here Reply from 208 132 180 48 bytes 32 times 2ms TTL 32 C Program Files Extron Variables are written in slanted form as shown here ping xxx xxx xxx xxx t SOH R Data STX...

Page 6: ......

Page 7: ... the Software 16 TLP Pro 1022 Series Web Pages 16 Updating the Firmware 17 Downloading Firmware 17 Updating Firmware Using the Touchpanel Web Page 17 Updating Firmware Using Toolbelt 17 Mounting 18 Mounting the TLP Pro 1022M 18 Wall Mounting 18 Furniture Mounting 20 Mounting the TLP Pro 1022T 21 Removing the Base and Back Covers 21 Kensington Security Lock 21 Desktop Mounting 22 VESA Mounting 22 R...

Page 8: ...TLP Pro 1022 Series Contents viii ...

Page 9: ...onfiguration and control of an AV system A motion sensor light sensor and two speakers provide sleep mode auto dimming and audible feedback Features 10 inch capacitive touchscreen with 1024x600 resolution and 18 bit color depth Vibrant edge to edge glass display with a more responsive control surface Faster processing and more memory Allows for quicker configuration uploads and more storage for GU...

Page 10: ... STORE 12V 0 4A MAX HDMI POWER HDMI ON 1 2 POWER 12V 0 7A MAX L R L 8Ω 4Ω CLASS 2 WIRING R 10V V C G 50mA L MPA 152 Plus R INPUTS OUTPUTS REMOTE POWER 12V A MAX G Tx Rx RTS CTS COM 1 G Tx Rx COM 2 V C G VOL RELAYS 1 2 C 1 2 3 4 G DIGITAL I O PWR OUT 6W eBUS V S S G LAN IPCP PRO 250 IR S S G STANDBY ON PQLS HDMI OPEN CLOSE FL OFF USB 1 2 3 4 5 6 7 8 9 0 _ Q W E R T Y U I O P A S D F G H J Z X C V B...

Page 11: ...ge 6 Ne branchez pas les écrans tactiles ou les contrôleurs avant d avoir lu les mises en garde page 6 Connect cables to the touchpanels see Rear Panel Features on page 5 Connect the power cords and power on all devices see LAN PoE Connector on page 5 4 Set up the Touchpanels for Network Communication Connect the PC that you are using for setup the Extron control processor and the touchpanel to th...

Page 12: ... processor Blinks red if the touchpanel has been configured but is not connected to an IP Link Pro control processor Solidly lit if the touchpanel has not been configured The indicator can be toggled between enabled and disabled using the Setup Menu see page 8 B Status light can be programmed to provide system feedback Light red or green Blink or solidly lit For information about programming this ...

Page 13: ... F Status light TLP Pro 1022T only C Menu button G VESA mounting holes TLP Pro 1022T only D LAN PoE connector H Base attachment hinges TLP Pro 1022T only Figure 3 TLP Pro 1022 Series Rear Panels A Reset LED indicates power status and reset status of the device see Reset Modes on page 23 B Reset button initiates one of three reset modes for the unit see Reset Modes on page 23 C Menu button activate...

Page 14: ...mum 0 35 A Ces produits sont destiné à une utilisation avec une source d alimentation listée UL avec l appellation Classe 2 ou LPS et normée 48 Vcc PoE 0 35 A minimum Extron power supplies are certified to UL CSA 60950 1 and are classified as LPS Limited Power Source Use of a non LPS or unlisted power supply will void all regulatory compliance certification Les sources d alimentation Extron sont q...

Page 15: ...Link Pro touchpanel See the www extron com for a list of suggested models The network port has two LEDs The green LED lights steadily to indicate that the touchpanel is connected correctly to a network The yellow LED flashes to indicate that data is being passed to or from the touchpanel E Mounting holes 4 TLP Pro 1022M only see figure 3 for wall mounting see Wall Mounting on page 18 F Status ligh...

Page 16: ... similar Status Press the Status button in the navigation panel at the top of the screen to open the Status screen Status Display Audio Advanced Exit Network Info Model TLP Pro 1022M Part Number 60 1602 02 Firmware Version 1 02 0001 b001 PoE Status Active Network IP Address DHCP Host Name Off 192 168 254 251 TLP AB CD EF Display Resolution GUI Project Sleep Timer 1024x600 N A 5 Minutes Audio Maste...

Page 17: ...0 05 A6 AB CD EF Revert Apply 127 0 0 1 Figure 6 Network Screen 1 If IP addresses are assigned by DHCP press On The selected button is highlighted in yellow If DHCP is selected you can set only the Host Name and the DNS IP address All other values are set by the DHCP server If IP addresses are assigned manually press Off When DHCP is Off all values can be edited 2 Edit the Host Name by pressing th...

Page 18: ... number for example 892 you are able to enter the 89 but the 2 cannot be entered Click Back to delete the last digit If no value has been entered for the selected octet pressing Back moves the cursor back to the previous octet and deletes the last digit of that octet e Press the next octet button and enter a value f Repeat steps c e until values have been entered for all four octets g Press OK to ...

Page 19: ...he panel is inactive before it enters sleep mode when the screen goes dark to save power Toggle between On and Off If the sleep timer is On use the arrows to adjust the value between 1 and 120 minutes Auto Brightness provides a suitable amount of backlighting that is automatically calculated from the amount of ambient light detected by the light sensor see figure 2 C on page 4 LCD Brightness allow...

Page 20: ... of each panel to toggle between audio on and audio mute The Sound audio is muted in figure 10 Advanced Press the Advanced button in the navigation panel at the top of the screen to open the Advanced screen Status Display Audio Advanced Exit Network System Touchpanel Name Controller Name Controller IP TLP AB CD EF IPCP 505 North Hall 192 168 254 11 Global Configurator Project Name NorthHall Versio...

Page 21: ... entered on the second occasion matches the PIN entered on the first occasion the PIN is set and the dialog closes Communication LED The LED can be enabled or disabled Calibration Screen Touch crosshair to calibrate 1024x600 Figure 13 Calibration Screen 1 Press and hold down the Menu button for at least 3 seconds The Menu button is located on the rear panel see figure 3 C on page 5 2 Release the b...

Page 22: ...ch is a Windows based application You can either customize an existing template or create an entirely new interface GUI Designer offers several templates After the user interface has been designed on a PC the project is saved built and imported into Global Configurator where the appropriate control functions are assigned to the text and graphic items of the interface After assigning the control fu...

Page 23: ... the alphabet menu ALL A B C D E F G H I J K M L N P O Q T S R U V W X Y Z Figure 15 Alphabet Software Menu 3 Click the initial letter of the software product 4 Scroll through the search results until you find it GUI Designer Click the Download button next to the program and follow the on screen instructions Global Configurator Ensure you are downloading Global Configurator Plus and Professional C...

Page 24: ...nnected to the same subnet There is a single read only page that provides general and network information about the unit see figure 16 below It also allows you to upgrade the unit firmware A dialog opens asking for your user name and password By default the user name is admin and the password is extron both user name and password are all lower case Use the Setup Menu see page 8 or Toolbelt to conf...

Page 25: ... for your model 6 Click Release Notes for more information about the firmware 7 Click Download 8 Follow the onscreen instructions to download the program Make a note of where the firmware is stored on the PC Updating Firmware Using the Touchpanel Web Page 1 If you have not already done so download the firmware file to a computer on the same network as the touchpanel see the previous section 2 Open...

Page 26: ... and electrical installation must be performed by qualified personnel in accordance with local and national building codes and electrical codes Toute étape structurelle et installation électrique doit être effectuée par un personnel qualifié conformément aux codes du bâtiment aux codes incendie et sécurité et aux codes électriques locaux et nationaux Some local building codes require the touchpane...

Page 27: ... BB 710M Installation Guide see www extron com 2 Place the metal mounting plate against the wall mark the four mounting holes and drill four pilot holes 3 Fasten the mounting plate to the wall with four 10 screws not provided 4 Insert the two provided Phillips pan head 6 32 x inch length screws with washers in the mounting screw slot 5 Run and connect cables to the back of the touchpanel see Rear ...

Page 28: ...as wall Mounting without a wall box above 1 Download the cut out template for your touchpanel from www extron com Print it at 100 no scaling 2 Use the template to mark the furniture surface cut the hole and drill the four pilot holes The size of the cut out hole is 7 68 inches 19 51 cm wide x 5 93 inches 15 06 cm high ATTENTION All structural steps and electrical installation must be performed by ...

Page 29: ... Remove the base cover using the provided Extron removal tool There is a notch at the back edge of the cover see figure 20 2 1 1 2 2 Figure 20 Rear of TLP Pro 1022T Base 2 When the base cover is removed a pull tab can be seen see figure 21 Use this to remove the back cover Pull Tab to Remove Back Cover Figure 21 TLP Pro 1022T with Base Cover Removed NOTE When replacing the covers attach the back c...

Page 30: ...e at the bottom of the base see figure 22 B This releases the weight which can be removed from the top of the base leaving the mounting hole that fits over the conduit of the SMA 1 3 Attach the conduit insulation disk and swivel disk and configure the set screws to allow for the degree of swivel that is required see the SMA 1 Swivel Mount Adapter Kit User Guide available at www extron com 4 Place ...

Page 31: ...see figure 3 B on page 5 Use Factory Firmware This mode is used to boot up the unit with factory installed firmware for a single power cycle in the event of a firmware update that failed or incompatibility issues arising with user loaded firmware Activation To start the Use Factory Firmware reset mode and replace firmware 1 On the touchpanel hold down the recessed Reset button while applying power...

Page 32: ... 255 255 255 0 Sets the default gateway address to the factory default 0 0 0 0 Sets all other IP settings addresses and domain and host names back to factory default Turns DHCP off Reset to Factory Defaults This mode resets all IP settings and touchpanel settings to factory defaults and removes all configurations It allows you to start over with configuration and uploading Activation To reset the ...

Page 33: ...on and ask for an Application Engineer to receive an RA Return Authorization number This will begin the repair process USA 714 491 1500 or 800 633 9876 Europe 31 33 453 4040 Asia 65 6383 4400 Japan 81 3 3511 7655 Units must be returned insured with shipping charges prepaid If not insured you assume the risk of loss or damage during shipment Returned units must include the serial number and a descr...

Reviews: