Show Me Button LEDs Stay Off When Pressed:

Cause 1

 — The cable is not plugged into a source device that is producing an active video output signal:

Solution — Verify that the source device is on and producing an active signal.

Cause 2

 — Contact or Tally wiring is incorrect:

Solution — See 

Show Me Cables

 (page 7) to ensure the contact and tally pins are correctly wired.

Cause 3

 — The switcher is not powered on:

Solution — Verify that the switcher is powered 

on

.

Cause 4

 — Problem with Show Me cable:

Solution — Try connecting the video source to a different cable. If the second cable works correctly, there may be a problem 
with the Show Me cable. Contact an Extron Support representative at 

www.extron.com/company/contactus.aspx

.

Cause 5

 — Problem with Switcher:

Solution — If none of the cables work correctly, there may be a problem with the switcher. Contact an Extron Support 
representative at 

www.extron.com/company/contactus.aspx

.

Cause 6

 — The source device does not 5V:

Solution — This is a problem with the source device. HDMI specifications require pin 18 to carry a +5V output and VGA 
specifications require pin 9 to carry a +5V output.

The Display Does Not Automatically Turn On:

Cause 1

 — Incorrect wiring:

Solution — Verify that the RS-232 communication cable is connected properly between the IPLink controller and Extron 
switcher.

Cause 2

 — There is no video signal present at Show Me cables:

Solution — Verify that an active signal is present at the input of any of the Show Me cables.

Cause 3

 — IPLink configuration is missing or corrupted:

Solution — Contact an Extron Support representative at 

www.extron.com/company/contactus.aspx

.

Cause 4

 — Display power is out of sync:

Solution — The display is in standby mode. Turn on the display using the remote or the physical power button.

Cause 5

 — Display has sleep mode enabled:

Solution — Go to the menu for the display and disable the sleep mode feature. Turn on the display using the remote or 
physical power button.

The Display Stays On and Never Turns Off:

Cause 1

 — Video signal is present at Show Me cables:

Solution — Verify that no active signals are present at the inputs of any of the Show Me cables. The TeamWork system is 
designed to turn off the Display only when no video signals are present.

Summary of Contents for TeamWork 601

Page 1: ...sure Tally Regional Sales 0 30 60 90 120 150 SOUTH NORTH EAST WEST 1402 nclosure The diagram above shows a typical TeamWork 601 application Digital or Analog input devices laptops and a tablet connect...

Page 2: ...1 Video switcher 1 MPS 601 2 VGA and 4 HDMI inputs System controller 1 IPL T PC1 Cable Cubby 1402 1 Power modules 2 US modules included 4 AC outlets total HDMI Show Me cables 4 VGA Show Me cables 2 HD...

Page 3: ...o not have integrated speakers and will not support audio playback Typically source devices with HDMI output connectors embed audio onto the HDMI connector NOTES Always check and test compatibility be...

Page 4: ...la LED se connecte aux appareils d entr e et doit ressortir du haut du Cable Cubby The end with the three conductor pigtail connects to the switcher and must come out of the bottom of the Cable Cubby...

Page 5: ...I Show Me Cable VGA Show Me Cable IPL T PC1 R 100 TX RX INPUT IR LINK ACT POWER System Controller Switcher Power Supply AC Power To Display MPS 601 MEDIA PRESENTATION SWITCHER CONFIG SIGNAL INPUTS INP...

Page 6: ...les 0 30 60 90 12 0 15 0 SO UT H NO RT H EA ST WES T Extron MPS 601 Switcher Extron IPL T PC1 System Controller RS 232 Control Cable HDMI VGA Extron HDMI Pro Cable HDMI Video Flat Panel Display w Inte...

Page 7: ...DMI connector Three conductor pigtail for contact closure and tally Extron MPS 601 Switcher CONTACT IN TALLY OUT G C 1 3 5 2 4 6 T T C G T C G G C T T C G T C G Black T Red C Pigtail Drain wire not us...

Page 8: ...RX Switcher MPS 601 3 pole connector to switcher 4 pole connector to system controller Switcher Control Cable RS 232 Tx Rx G REMOTE ATTENTION The two ends of the RS 232 control cable are different On...

Page 9: ...When the button on the second Show Me cable is pressed the LED lights blue and the LED on the first cable is switched off 10 Disconnect all the Show Me cables from the source devices After about 30 se...

Page 10: ...us aspx Cause 6 The source device does not output 5V Solution This is a problem with the source device HDMI specifications require pin 18 to carry a 5V output and VGA specifications require pin 9 to c...

Reviews: