Use this volume adjustment knob to set or adjust the program output volume
(attenuation, from -100 dB to 0 dB) as desired. The LEDs indicate the overall
percentage level for Group Master 1; the volume level being all off (0%) at -100 dB
through to all on (100%) at -4 to 0 dB. Any level changes made do not affect the mic
audio.
Rotate the knob clockwise to increase volume,
counter-clockwise to decrease volume. The
corresponding LEDS light as the knob is rotated.
See the table at right for LED/dB values.
Volume control of Group 1 individual program
outputs (programs 1, 3, or 4) can be made
through DSP Configurator software. Group 1
can be reconfigured through DSP Configurator
software.
f
Mic volume adjustment knob
—
This knob
is assigned to Group Master 2, which controls
the mic inputs at the second gain block, pre-mic
mixer-gain programs (
). By default it controls both microphones, and
level changes do not affect the program audio.
Use this knob to set or adjust the two MIC volumes as desired from -100 dB to 0 dB.
The LEDs indicate the volume level. See the table at above right for LED/dB values.
Rotate the knob clockwise to increase volume, counter-clockwise to decrease volume.
The corresponding LEDS light as the knob is rotated.
Volume control of Group 2 individual mic levels (mic pre-mixer gains 1 and 2) can be
made through DSP Configurator software.
Group 2 can be reconfigured through DSP Configurator software.
NOTE:
The program and mic volume settings and adjustments can also be made
using Extron DSP Configurator program or by Simple Instruction Set (SIS)
Using the DSP Configurator Software
”section
” section for details.
Using EDIDs
EDID Minder
This pre-installed feature ensures that all sources power up properly and reliably
output content for display. EDIDs (resolution and refresh rates) for digital inputs can be
automatically assigned when connecting a display with a common resolution and refresh
rate. For both analog and digital, the user can assign a different EDID from an EDID table.
A different EDID (as given in the table on the next page), can be manually assigned using
SIS commands or via DSP Configurator.
For the MLS 608 D units, the default settings are 1024x768 at 60 Hz for analog inputs,
and 720p at 60 Hz, 2-channel PCM audio for digital inputs.
NOTES:
•
To work with the EDID Minder, update the EDID table, and import or export
EDID data, the MLS 608 D must be connected in Live mode.
VOLUME
LED equivalent
dB value
-4 to 0
-9 to -5
-14 to -10
-19 to -15
-29 to -20
-49 to -30
- 69 to -50
-99.9 to -70
-100 (all LEDs
off)
MLS 608 D Series • Operation