Specifications — MLC 226 Series

1

Extron MLC 226 Series MediaLink

®

 Controllers • Specifications

IP Intercom

Connection type (IPI–MLC).........  RJ-45 jack for CAT 5, CAT 5e, or CAT 6 cable
Audio

Frequency response ..........  20 Hz to 3.3 kHz, ±1 dB
Audio processing

Audio format .............  PCM, µ-law companded
Sampling rate .............  8 kHz
Sample size .................  16 bit, µ-law companded to 8 bit
Audio latency.............  Software: 30 ms through 160 ms 

Network: <150 ms, typical

Audio output

Number/signal type .........  1 mono (for use with an optional IP Intercom)
Line level output ...............  -10 dBV (316 mVrms), unbalanced (via 3.5 mm captive screw connector, 

2 pole)

Communication

Transport bandwidth for IPI control and audio, half duplex 

80 kbps (0.08% of 100Base-T

Ethernet protocol ...............  TCP/IP (control), UDP (audio)

 Control — host ports

Serial host port ...............................  2 bidirectional RS-232: 1 rear panel 9-pin female D connector (shared with 

digital input), 1 front panel 2.5 mm mini stereo jack

Baud rate and protocol .................  38400, 8 data bits, 1 stop bit, no parity
Serial control pin configurations .  9-pin female D connector: 2 = TX, 3 = RX, 5 = GND 

Mini stereo jack: tip = TX, ring = RX, sleeve = GND

Ethernet host port .........................  1 RJ-45 female
Ethernet data rate (for network communication) 

10/100Base-T, half/full duplex with autodetect

Ethernet protocol ...........................  ARP, DHCP, ICMP (ping), TCP/IP, Telnet, HTTP, SMTP
Ethernet default settings ..............  Link speed and duplex level = autodetected 

IP address = 192.168.254.254 

Subnet mask = 255.255.0.0 

Default gateway = 0.0.0.0 

DHCP = off

Web server ......................................  Up to 200 simultaneous sessions 

7.25 MB nonvolatile user memory

Secondary control panel (SCP) ....  (1) 3.5 mm 5-pole direct insertion captive screw connector (shared with 

control module and IR Link port)

IR remote control ...........................  IR 402 (optional) 

Front panel: 30' maximum, 40 degrees off axis 

Rear panel: 38 kHz, hardwired, modulated

Program control .............................  Extron's configuration program for Windows

®

 

Extron's Simple Instruction Set (SIS

Microsoft

® 

Internet Explorer, Telnet

IR learning frequencies .................  30 kHz to 62 kHz
IR learning distance ......................  2" (5.1 cm) to 12" (30.5 cm) from the front panel

 Control — relay

Number/type ................................  6 momentary or latching (configurable via software)
Connectors .....................................  (3) 3.5 mm captive screw connectors, 3 pole
Connector configuration ..............  Groups A, B, C; each with 1 common and 2 normally open relays (default)
Contact rating ................................  24 V, 1 A

Summary of Contents for MLC 226 IP Series

Page 1: ...X 3 RX 5 GND Mini stereo jack tip TX ring RX sleeve GND Ethernet host port 1 RJ 45 female Ethernet data rate for network communication 10 100Base T half full duplex with autodetect Ethernet protocol ARP DHCP ICMP ping TCP IP Telnet HTTP SMTP Ethernet default settings Link speed and duplex level autodetected IP address 192 168 254 254 Subnet mask 255 255 0 0 Default gateway 0 0 0 0 DHCP off Web ser...

Page 2: ...ion captive screw connector shared with power sense port Pin configuration 9 pin female D connector 1 digital input 5 GND power sense digital in GND GND Digital inputs Input voltage range 0 12 VDC Input impedance 28k ohms Programmable pullup 2k ohms to 5 VDC Threshold low to high 2 8 VDC Threshold high to low 2 0VDC Digital output 250 mA sink from 24 VDC maximum General External power supply 100 V...

Page 3: ...D 11 4 cm H x 25 4 cm W x 0 3 cm D 5 gang MLC 226 L faceplate 3 15 H x 6 5 W x 0 1 D 8 0 cm H x 16 5 cm W x 0 3 cm D Device MLC 226 IP DV 2 75 H x 5 3 W x 2 0 D 7 0 cm H x 13 5 cm W x 5 9 cm D and 2 7 H x 2 6 W x 0 9 D 6 9 cm H x 6 6 cm W x 2 3 cm D Depth excludes knob and buttons Fits some 5 gang boxes Allow at least 2 1 5 3 cm depth in the wall or furniture MLC 226 IP DV Rear 4 5 10 1 5 25 2 1 2...

Page 4: ...ntrollers Specifications 4 All other models 2 75 H x 5 3 W x 2 0 D 7 0 cm H x 13 5 cm W x 5 9 cm D Depth excludes knob and buttons Fits some 3 gang boxes MLC 226 IP Rear 4 5 MLC 226 IP L Rear 3 15 6 5 6 4 5 25 2 1 2 7 5 25 2 1 2 7 MLC 226 IP AAP Rear 4 5 10 1 5 25 2 1 2 7 ...

Page 5: ...ton International Safe Transit Association Regulatory compliance Safety CE C tick CUL UL EMI EMC CE C tick FCC Class A VCCI ICES Accessibility Complies with the appropriate requirements of Section 508 of the Rehabilitation Act 29U S C 794d MTBF 30 000 hours Warranty 3 years parts and labor N All nominal levels are at 10 N Specifications are subject to change without notice 7 6 070808 D12 ...

Reviews: