MLC 104 IP Plus Series • Operation, Features, and Cabling
32
MLC 104 IP Plus Series Controller Reset Mode Summary
Mode Activation
Result
Purpose and
Notes
Reset to
Factory Defaults
5
Hold down the Reset button for about
9 seconds until the Reset LED blinks
three
times (once at 3 seconds, again at
6 seconds, again at 9 seconds).
Then release and press Reset momentarily
(for <1 second) within 1 second*.
Mode 5 performs a complete reset to factory defaults
(except the firmware).
•
Does everything mode 4 does
•
Resets almost all the real-time adjustments: all audio settings,
limit initial power up volume, power up/down delay, auto
power down, and miscellaneous options. This does not affect
an optional MLS or PVS switcher, however.
•
Clears driver-port associations and port configurations (IR and
serial)
•
Removes button configurations
•
Resets all IP options
•
Removes scheduling settings
•
Removes/clears all files from the MLC controller
The Reset LED flashes four times in quick succession during reset.
Mode 5 is useful
if you want to
start over with
configuration and
uploading, and also
to replace events.
This is identical
to SIS command
ZQQQ
]
.
*For modes 3, 4, and 5, nothing happens if the momentary press does not occur within 1 second.
Pinout Guides
The following illustration summarizes the pin assignments of all of the MLC bottom panel
connectors that are covered in detail on the preceding pages.
12
3
GROUND
+V OUT
CM
GROUND
IR OUT
GROUND
SCP
GROUND
Tx
Rx
DISPLA
Y
RS-232/IR
A B C D
E
COMM LINK
AB
ML
S
RS-232
POWE
R
12
V
DIGI
TA
L
I/
O
IR IN
Tx
GROUND
Rx
+12V IN
LAN
PR
ESS
T
AB WITH
TWEEKER
TO
RE
M
O
VE
LAN
MLC 104 IP Plus
Right Side Panel
To (output) or from (input) sensors, switches,
control equipment (screen controllers,
lights, relays), LEDs
Ground
Transmit (Tx)
Receive (Rx)
To/from an optional Extron switcher
From an external 12 VDC, 0.5 A (max.) power supply
or
an Extron switcher
Ground
Receive (Rx)
Transmit (Tx)
To a projector
or display
RS-232
IR
IR Output
Ground
Digital I/O
Digital I/O
Digital I/O
Ground
+12 VDC input
SCP communication (IR)
Modulated IR (for IRL 20)
Ground
IRCM, CM
+12 VDC
To and from optional Extron
control modules, IR repeater,
or SCP control pads
To / from LAN
or Internet
OR
Figure 15.
Right Side Panel Port and Pin Configuration Summary