Extron electronics MD Floor Box AAP Bracket Kit AAP 100 MD Installation Manual Download Page 1

Extron AAP 100 and MAAP 100 Installation Guide

The following procedure is for mounting the AAP 100 and MAAP 100 panels 

on hard surfaces (plywood, hardwood, etc.).  For soft surfaces (particle 

board, drywall, etc.), additional hardware such as anchors may be required 

(not provided).

1.

  Make a copy of the appropriate full size rough-in template.  Cut out the 

center portion of the template up to the dashed guidelines.

C

  For accurate sizing, copy the template at exactly 100%.

2.

  Place the template in the desired location and mark the guidelines for 

the opening on the surface.

3.

  Carefully cut away the material inside the guidelines.  Check the 

opening size by placing the panel against the opening. 

4.

  Cable the AAP(s)/MAAP(s) and install them on the panel. 

5.

  Place the panel against the surface and mark the locations of the two 

wall mounting holes on the surface.

6.

  Remove the panel and drill 1/4" deep pilot holes (half the width of the 

shaft of the screw) at the marked locations.  Replace the panel. 

7.

  Use two 1/2" (1.3  cm) long, #6 flat headed wood screws (provided) to 

fasten the panel directly onto the surface.  Hand tighten the screws. 

Product Dimensions

68-837-01 

Rev. B

08 08

AAP 100 pnl.eps

1.750

2 x 0.875

0.000

0.250

4.250

4.500

0.000

0.100

MAAP 100 pnl.eps

0.000

0.250

3.000

3.250

1.750

2 x 0.875

0.000

0.100

The dashed line indicates the 

recommended cut-out area 

for the installation surface.

1.5" H x 2.25" W

(3.8 cm H x 5.7 cm W)

The solid, outer line  

represents the outside

 edge of the panel.

1.75" H x 3.25" W

(4.45 cm H x 8.25 cm W) 

The dashed line indicates the 

recommended cut-out area 

for the installation surface.

1.5" H x 3.5" W 

(3.8 cm H x 8.9 cm W) 

The solid, outer line  

represents the outside

 edge of the panel.

1.75" H x 4.5" W

(4.45 cm H x 11.4 cm W) 

Template for 

the AAP 100

Template for 

the MAAP 100

Installation Templates

© 2008  Extron Electronics.  All rights reserved.

Extron 

USA - West

 

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500

+1.714.491.1517

 

FAX

Extron 

USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794

+1.919.863.1797

 

FAX

Extron 

Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 

FAX

Extron 

Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400

+65.6383.4664

 

FAX

Extron 

Japan

+81.3.3511.7655

+81.3.3511.7656

 

FAX

Extron 

China

+400.883.1568

Inside China Only

+86.21.3760.1568

+86.21.3760.1566

 

FAX

Extron 

Dubai

+971.4.2991800

+971.4.2991880

 

FAX

The dashed line indicates the 

recommended cut-out area 

for the installation surface.

1.5" H x 2.25" W

(3.8 cm H x 5.7 cm W)

The solid, outer line  

represents the outside

 edge of the panel.

1.75" H x 3.25" W

(4.45 cm H x 8.25 cm W) 

The dashed line indicates the 

recommended cut-out area 

for the installation surface.

1.5" H x 3.5" W 

(3.8 cm H x 8.9 cm W) 

The solid, outer line  

represents the outside

 edge of the panel.

1.75" H x 4.5" W

(4.45 cm H x 11.4 cm W) 

Template for 

the AAP 100

Template for 

the MAAP 100

Reviews: