IN1608 xi Scaling Presentation Switcher • SIS Configuration and Control
50
X(
= Enable or disable
0
= off or disabled
1
= on or enabled
X1)
= Input standard
0
= no signal detected on the current
input
1
= NTSC 3.85
2
= PAL
3
= NTSC 4.43
4
= SECAM
–
= N/A (occurs when the input is active RGB,
YUV, or HDMI signal)
X1!
= Internal temperature
In degrees Celsius
X1@
= Film detect mode
0
= disabled
1
= auto (default)
X1#
= Horizontal and vertical
frequencies
nnn.n
X1$
= Text label
Up to 63 characters, with the following
restrictions:
•
Only alphanumeric characters, the
underscore (_), and the hyphen (-) can be
used.
•
1 to 52 characters are permitted.
•
The first character must be a letter.
•
The last character
cannot
be a hyphen.
X1%
= Picture adjustment
0-127
(
64
= default)
X1^
= Horizontal position
±2048
X1&
= Vertical position
±1200
X1*
= Horizontal size
10-04096
X1(
= Vertical size
10-02400
X2)
= Test patterns
0
= off (default)
1
= crop
2
= alternating pixels
3
= color bars
4
= grayscale
5
= blue mode
6
= audio test pattern (pink noise)
X2!
= User presets
01-16
X2@
= Input presets
1-128
X2#
= On-screen display bug
time-out Output sync time-
out
0
= OSD is never displayed, output sync is
instantly disabled with no active input
1-500
= 1 second increments
3
= OSD bug time-out default
501
= OSD bug never times out,
output sync never times out
X2$
= Front panel lockout
(executive mode) status
0
= off or disabled (default)
1
= mode 1 (complete front panel lockout)
2
= mode 2 (only allow input switching and
volume control)