Step 2 

 Connect inputs

a. 

Connect analog video sources to the VGA connectors (see figure 1, 

B

 on page 1).

b. 

Connect digital HDMI or DVI (with an appropriate adapter) sources to the HDMI connectors (see figure 1, 

C

).

c. 

Connect a DTP transmitter to the DTP input connectors (see figure 1, 

D

). For cable wiring and recommendations, see 

Twisted Pair 

Recommendations for DTP and HDBaseT Communication

 below.

Signal LED

 

 Lights green when the unit is receiving an active video signal from a DTP transmitter. 

Link LED

 

 Lights amber when a valid link is established to a DTP transmitter.

d. 

To pass serial or infrared data, connect the control device to the RS-232 and IR Over DTP captive screw connectors (see 

RS-232 and IR 

Over TP Wiring

 on page 3).

e. 

Connect analog audio input sources to the 5-pole captive screw connectors (see figure 1, 

E

). See 

Audio Wiring

 on page 3.

f. 

Connect Mic/Line audio input sources to the 3-pole captive screw connectors (see figure 1, 

F

).

Step 3 

 Connect outputs

a. 

Connect an HDBaseT-compatible device to the HDBT output connector (see figure 1, 

G

). For cable wiring and recommendations, see 

Twisted Pair Recommendations for DTP and HDBaseT Communication

 below. 

Signal LED

 

 Lights green when the scaler is outputting active video. 

Link LED

 

 Lights amber when a valid link is established between the scaler and HDBaseT sink.

b. 

To pass serial or infrared data, connect a control device to the RS-232 and IR Over HDBT captive screw connector (see 

RS-232 and IR 

Over TP Wiring

 on page 3).

c. 

Connect suitable video displays to the HDMI connectors (see figure 1, 

H

).

d. 

Connect analog audio output devices to the 3.5 mm, 5-pole captive screw connectors (see figure 1, 

I

). See 

Audio Wiring

 on page 3.

e. 

For SA and MA models, connect an audio output device to the 5 mm, 4-pole or 2-pole captive screw connector (see figure 1, 

J

).

Step 4 

 Connect control devices

a. 

To control non-IPCP models through Ethernet, connect a LAN or WAN to the LAN connector (see 

M

 on page 1). For the IPCP models,  

connect a LAN or WAN to any of the LAN connectors on the IPCP Pro control processor (see figure 1, 

L

). The default IP address is 

192.168.254.254. The default subnet mask is 255.255.0.0.

b. 

For serial RS-232 control, connect a host device to the 3-pole captive screw connector (see figure 1, 

K

). The default baud rate is 9600.

c. 

For control through USB, connect a host device to the front panel USB mini-B port (see figure 2, 

A

 on page 3).

Step 5 

 Set up the IPCP Pro control processor (IPCP models only)

See the 

IPCP Pro Series Setup Guide

 for installation details.

Step 6 

 Connect power

Connect a 100 to 240 VAC, 50-60 Hz power source to the AC power connector (see figure 1, 

A

).

Twisted Pair Recommendations for DTP and HDBaseT Communication

Extron recommends using the following practices to achieve full transmission distances and reduce 
transmission errors:

• 

Use Extron XTP DTP 24 SF/UTP cable for the best performance. At a minimum, Extron recommends 
24 AWG, solid conductor, STP cable with a minimum bandwidth of 400 MHz.

• 

Terminate cables with shielded connectors to the TIA/EIA-T568B standard (shown to the right).

• 

Limit the use of more than two pass-through points, which may include patch points, punch down 
connectors, couplers, and power injectors. If these pass-through points are required, use shielded 
couplers and punch down connectors.

ATTENTION:

 

• 

Do not connect these connectors to a computer or telecommunications network.

• 

Ne connectez pas ces ports à des données informatiques ou à un réseau de télécommunications.

• 

DTP remote power is intended for indoor use only. No part of the network that uses DTP remote power should be routed outdoors.

• 

L’alimentation DTP à distance est destiné à une utilisation en intérieur seulement. Aucune partie du réseau qui utilise l’alimentation DTP 
à distance ne peut être routée en extérieur.

NOTE:

 

When using shielded twisted pair cable in bundles or conduits, consider the following:

• 

Do not exceed 40% fill capacity in conduits.

• 

Do not comb the cable for the first 20 meters, where cables are straightened, aligned, and secured in tight bundles.

• 

Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.

• 

Separate twisted pair cables from AC power cables.

TIA/EIA-T568B

Pin Wire Color

1

White-orange

2

Orange

3

White-green

4

Blue

5

White-blue

6

Green

7

White-brown

8

Brown

12345678

RJ-45

Connector

Insert Twisted

Pair Wires

Pins:

Pin

1

2

3

4

5

6

7

8

Wire color

White-green

Green

White-orange

Blue

White-blue

Orange

White-brown

Brown

Wire color

T568A

T568B

White-orange

Orange

White-green

Blue

White-blue

Green

White-brown

Brown