background image

 

HAE 100 4K Plus • Panels and Cabling

4

A

  Power input

 

— Connect the provided power supply to the 3.5 mm, 2-pole captive 

screw power receptacle (see figure 4).

SECTION  A–A

Ridges

Smooth

Power Supply Output Cord

A

A

3/16”

(5 mm) Max.

Figure 4. 

Power Connection

ATTENTION:

 

• 

The length of the exposed wires in the stripping process is critical. The ideal length 
is 3/16 inches (5 mm). Any longer and the exposed wires may touch, causing a 
short circuit between them. Any shorter and the wires can be easily pulled out even 
if tightly fastened by the captive screws.

• 

La longueur des câbles exposés est primordiale lorsque l’on entreprend de les 
dénuder. La longueur idéale est de 5 mm (3/16 inches). S’ils sont un peu plus 
longs, les câbles exposés pourraient se toucher et provoquer un court circuit. S’ils 
sont un peu plus courts, ils pourraient sortir, même s’ils sont attachés par les vis 
captives.

• 

Always use a power supply supplied by or specified by Extron. Use of an 
unauthorized power supply voids all regulatory compliance certification and may 
cause damage to the supply and the end product.

• 

Utilisez toujours une source d’alimentation fournie par Extron. L’utilisation d’une 
source d’alimentation non autorisée annule toute conformité réglementaire et peut 
endommager la source d’alimentation ainsi que l’unité.

• 

If not provided with a power supply, this product is intended to be supplied by a 
power source marked “Class 2” or “LPS” and rated at 12 VDC and a minimum of 
1.0 A.

• 

Si ce produit ne dispose pas de sa propre source d’alimentation électrique, il doit 
être alimenté par une source d’alimentation de classe 2 ou LPS et paramétré à  
12 V et 1.0 A minimum.

• 

Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling 
spaces or in wall cavities. The power supply is to be located within the same vicinity 
as the Extron AV processing equipment in an ordinary location, Pollution Degree 2, 
secured to the equipment rack within the dedicated closet, podium, or desk.

• 

Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une 
utilisation dans les espaces d’aération ou dans les cavités murales. La source 
d’alimentation doit être située à proximité de l’équipement de traitement audiovisuel 
dans un endroit ordinaire, avec un degré 2 de pollution, fixé à un équipement de 
rack à l’intérieur d’un placard, d’une estrade, ou d’un bureau.

• 

The installation must always be in accordance with the applicable provisions of 
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical 
Code part 1, section 16. The power supply shall not be permanently fixed to 
building structure or similar structure.

• 

Cette installation doit toujours être en accord avec les mesures qui s’applique 
au National Electrical Code ANSI/NFPA 70, article 725, et au Canadian Electrical 
Code, partie 1, section 16. La source d’alimentation ne devra pas être fixée de 
façon permanente à une structure de bâtiment ou à une structure similaire.

Summary of Contents for HAE 100 4K Plus

Page 1: ...User Guide HAE 100 4K Plus HDMI HDMI Audio Extractor 68 3113 01 Rev A 10 20 ...

Page 2: ...intenance importantes qui se trouvent dans la documentation fournie avec l équipement Pour en savoir plus sur les règles de sécurité la conformité à la réglementation la compatibilité EMI EMF l accessibilité et autres sujets connexes lisez les informations de sécurité et de conformité Extron réf 68 290 01 sur le site Extron www extron com Istruzioni di sicurezza Italiano AVVERTENZA Il simbolo se u...

Page 3: ...Point DTP eBUS EDID Manager EDID Minder eLink Flat Field FlexOS Glitch Free Global Configurator Global Scripter GlobalViewer Hideaway HyperLane IP Intercom IP Link Key Minder LinkLicense LockIt MediaLink MediaPort NAV NetPA PlenumVault PoleVault PowerCage PURE3 Quantum ShareLink Show Me SoundField SpeedMount SpeedSwitch StudioStation System INTEGRATOR TeamWork TouchLink V Lock VideoLounge VN Matri...

Page 4: ...e Guide on the Extron website Conventions Used in this Guide Notifications The following notifications are used in this guide ATTENTION Attention indicates a situation that may damage or destroy the product or associated equipment NOTE A note draws attention to important information Software Commands Commands are written in the fonts shown here AR Merge Scene Op1 scene 1 1 B 51 W C 01 R00040030000...

Page 5: ... bit depth support 7 Hot Plug Detect HPD 7 HDCP 7 Input 7 Output 7 SIS Commands 8 Connecting a Control Computer 8 Simple Instruction Set SIS Control 8 Host to Interface Communications 8 Error Responses 8 Timeout 8 Using the Command and Response Table 9 Command and Response Table for SIS Commands 9 Reference Information 13 Mounting 13 Tabletop Placement 13 Rack Mounting 13 Under desk and Furniture ...

Page 6: ...2 4 6 8 10 12 14 0 2 4 6 8 10 12 14 0 2 4 6 8 10 12 14 ATTENUATION INPUTS BRIDGE MODE 8Ω 4Ω OUTPUTS REMOTE 3 4 A B BRIDGE B CLASS 2 WIRING 1 2 3 4 ON OFF BRIDGE 8Ω ONLY BRIDGE A BRIDGE B 100 240V 1 5A 50 60 Hz STANDBY XPA 2004 GREEN ACTIVE AMBER STANDBY 1 G 2 2 1 4 3 3 4 LIMITER PROTECT SIGNAL 1 2 BRIDGE A 0 2 4 6 8 10 12 18 14 26 0 2 4 6 8 10 12 14 0 2 4 6 8 10 12 14 0 2 4 6 8 10 12 14 ATTENUATIO...

Page 7: ...DCP compliant device Protected material is not passed in non HDCP mode EDID Minder automatically manages EDID communication between connected devices EDID Minder ensures that the source powers up properly and reliably outputs content for display Selectable output format Allows the output video format and color space to be manually configured Automatic HDMI input cable equalization Actively conditi...

Page 8: ...atus of the HDMI input Signal This LED lights when the unit is receiving a signal on the HDMI input HDCP This LED lights when the input signal is HDCP encrypted D Audio input LEDs These two LEDs provide the status of the various HDMI and audio input functions 2 CH PCM This LED lights when the incoming embedded audio signal is a 2 channel Digital LPCM audio format Bitstream This LED lights when the...

Page 9: ...ied by a power source marked Class 2 or LPS and rated at 12 VDC and a minimum of 1 0 A Si ce produit ne dispose pas de sa propre source d alimentation électrique il doit être alimenté par une source d alimentation de classe 2 ou LPS et paramétré à 12 V et 1 0 A minimum Unless otherwise stated the AC DC adapters are not suitable for use in air handling spaces or in wall cavities The power supply is...

Page 10: ...al S PDIF audio formats 2 channel LPCM Dolby Digital or DTS that are extracted from the HDMI input signal NOTE The audio format is determined by the EDID assigned Using 2 channel EDID restricts the source device to outputting 2 channel LPCM and then extract and output it on the Analog and S PDIF connectors Using S PDIF EDID allows 2 channel LPCM Dolby Digital and DTS to be output by the source dev...

Page 11: ...al from the source The HAE 100 4K Plus scans and monitors the EDID of the sink device connected to the HDMI output It determines the interface DVI or HDMI and color depth and uses that information to adjust the signal so that it is compatible with the output device TMDS Output Format The TMDS output format has three components Video format either DVI or HDMI Color space RGB 4 4 4 YUV 4 2 2 or YUV ...

Page 12: ...ption The authentication process is repeated whenever the stored EDID is changed or updated HDCP support can be disabled using the Input HDCP Authorization SIS Command on page 10 Output The output is authenticated and encrypted according to the configured HDCP output mode see output modes below If the output requires encryption but the connected sink device cannot be authenticated the HAE 100 4K P...

Page 13: ...or end a command sequence When a command is valid the interface executes the command and sends a response to the host device All responses from the interface to the host end with a carriage return and a line feed CR LF which signals the end of the response character string A string is one or more characters Error Responses When the HAE 100 4K Plus receives a valid SIS command it executes the comma...

Page 14: ...put HDCP Status EOHDCP X1 HdcpOX1 Verbose mode 2 3 Input Audio Status 1S X AudIX Verbose mode 2 3 EDID Minder View EDID in HEX format EREDID X HEX data from currently assigned EDID View EDID Native Rate ENEDID X Example 1080P 60 0Hz KEY X Input audio status 0 No audio detected or detected audio cannot be de embedded 1 S PDIF Bitstream audio detected 2 2 Ch LPCM detected X 0 off disabled or not det...

Page 15: ...lug Mode 5V Status EMHPLG X1 KEY X Video mute 0 off default 1 video only 2 video sync X 0 off disabled or not detected 1 on enabled or detected X Output HDCP mode 1 default Encrypt as required by input Continuous trials for HDMI sinks attempt for 10s on DVI sinks then fail 2 Always encrypt Continuous trials for HDMI sinks attempt for 10s on DVI sinks then fail X Output TMDS format 1 Auto default 2...

Page 16: ... Info Other Information I AudIX SigX X HdcpIX1 HdcpOX1 Input audio input output signal and HDCP status KEY X Input audio status 0 No audio detected or detected audio cannot be de embedded 1 S PDIF Bitstream audio detected 2 2 Ch LPCM detected X 0 off disabled or not detected 1 on enabled or detected X1 Input HDCP status 0 No active video source detected 1 Video detected without HDCP not encrypted ...

Page 17: ...odel Description 2I HDMI Audio De Embedder Inf02 HDMI Audio De Embedder Verbose mode 2 3 Query Firmware Version Q x xx Query Firmware Version with Build Q x xx xxxx KEY X1 Verbose mode 0 clear none 1 verbose mode default 2 tagged responses for queries 3 verbose mode and tagged responses for queries X1 Device name NOTE The name is a text string of up to 24 characters drawn from the alphabet A Z dig...

Page 18: ...nment compatible with the maximum ambient temperature TMA 122 F 50 C specified by Extron 2 Reduced air flow Install the equipment in the rack so that safe operation and adequate air flow is provided to the unit 3 Mechanical loading Mount the equipment in the rack so that a hazardous condition is not achieved due to uneven mechanical loading 4 Circuit overloading Connect the equipment to the supply...

Page 19: ...sk and Furniture Mounting Mount the unit under a desk or podium using the under desk mounting kit Follow the instructions provided with the kit PCS Software The PCS software application can be used to update firmware and configure the HAE 100 4K Plus Downloading PCS 1 1 2 2 Figure 6 Software on the Extron Website 1 On the Extron website go to the Download tab see figure 6 1 and click Software 2 A ...

Page 20: ...com go to the Download tab and click Firmware see figure 9 1 Figure 8 Firmware Link on the Download Tab 2 In the Download Center screen navigate to the HAE 100 4K Plus see figure 9 1 NOTE Your device appears in this list only if a new version of the firmware has been released since the product was first introduced 1 1 Figure 9 Firmware Download Center 3 Ensure the available firmware version is a l...

Page 21: ...rica 3rd Floor South Tower 160 Jan Smuts Avenue Rosebank 2196 South Africa This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or if modifications were made to the product that were not authorized by Extron NOTE If a product is defective please call Extron and ask for an Application Engineer...

Reviews: