FOXBOX Tx / Rx • Remote Control
21
Simple Instruction Set Control
Host-to-Switcher Communications
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command character sequence. When a command is valid, the
switcher executes the command and sends a response to the host device. All responses
from the switcher to the host end with a carriage return and a line feed (CR/LF =
]
), which
signals the end of the response character string. A string is one or more characters.
Symbol Definitions
]
= Carriage return/line feed
}
= Carriage return (no line feed)
|
= Pipe (can be used interchangeably with the
}
character)
•
= space
E
= Escape key
W
= Can be used interchangeably with the
E
character
X!
= Status
0
= off
1
= on
X@
= Resolution
01
= 1920 x 1200
11
= 576p
02
= 800 x 600
12
= 720p
03
= 1024 x 768
13
= 1080i
04
= 1280 x 768
14
= 1080p
05
= 1280 x 1024
15
= 640 x 480
06
= 1365 x 768
16
= 1440 x 900
07
= 1366 x 768
17
= 1280 x 800
0
8 = 1400 x 1050
18
= 1680 x 1050
09
= 1600 x 1200
19
= 1360 x 768
10
= 480p
X#
= Refresh rate
1
= 50 Hz
2
= 60 Hz
X$
= Mode switch position
0
= off (down)
1
= on (up)
X%
= Output sync format
0
= RGBHV
1
= RGsB
X^
= Output sync polarity
0
= follows input
1
= force sync negative
X&
= Horizontal and vertical position
000
through
255
X*
= Horizontal start
000
through
255
X(
= Pixel phase
00
through
31
X1)
= Total pixels
±
255
of default value for selected resolution
X1!
= Sync frequency
xxx
.
xx
(frequency in kHz [H] or Hz [V])
X1@
= Memory preset number
01
to
30
X1#
= Audio gain adjustment range
00
to
10
X1$
= Audio level adjustment range
–18.0
to
+10.0
(in 1.0 dB steps)
X1%
= Audio attenuation adjustment range
00
to
18
X1^
= Test pattern
0
= none
2
= grayscale
1
= color bars
3
= alternating pixels
X1&
= Video shutdown interval
0
= 0 seconds (off)
4
= 1 second
1
= 0.25 second
5
= 1.25 second
2
= 0.5 second (default)
6
= 1.5 second
3
= 0.75 second
X1*
= Enable or disable
0
= disable
1 = enable (default)
X1(
= Link and input status
0
= link or input not sensed
1
= link or input sensed
X2)
= Transmission mode
SM
= singlemode
MM
= multimode
X2!
= Transmitter or receiver
Tx
= transmitter
Rx
= receiver
X2@
= Firmware version
v
.
vv
X2#
= Internal temperature
nnn
F
•
nn
C