DTP2 T 201 D Transmitter • Remote Configuration and Control
18
Command and Response Table for SIS Commands
Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional
Description
Verbose Mode
Set verbose mode
E
X!
CV
}
Vrb
X!
]
X!
:
1
= default.
View verbose mode
E
CV
}
X!
]
KEY:
X!
=
Verbose mode
0
= Clear/none;
1
= Verbose mode (default);
2
= Tagged responses for queries;
3
= Verbose mode and tagged responses for queries.
Unit Name
Set unit name
E
X@
CN
}
Ipn
•
X@
]
Set unit name to factory
default
E
•
CN
}
Ipn
•
DTP2‑T‑201‑D
]
Query unit name
E
CN
}
Verbose mode 2/3
X@
]
Ipn
•
X@
]
KEY:
X@
=
Text string of up to 24 characters (Default =
DTP2‑T‑201‑D)
.
Alphanumeric characters and hyphens only
No distinction between upper and lower case
No spaces
First character must be a letter and the last character cannot be a hyphen
View Firmware Information
Query firmware version
Q/q
x.xx
]
Firmware build with 2
decimals.
Query firmware version w/
build
*Q/q
x.xx.xxxx
]
Query detailed firmware
version
0Q/q
X#
]
Query build and any special
build text
20Q/q
X#
]
KEY:
X#
= Firmware version to the second decimal place.
DTP2 Remote Power
View input/output remote
power
E
RPWR
}
Verbose mode 2/3
X$
]
Rpwr
X$
]
View remote power
setting on DTP2.
KEY:
X$
= Remote
0
= No remote power (Off);
1
= DTP2 48 VDC (On).
Summary of Contents for DTP2 T 201 D
Page 2: ...Safety Instructions ...
Page 6: ......