DTP CrossPoint 84 • Installation
7
Serial and IR Insertion Connections
SIG LINK
OUT
SIG LINK
IN
SIG LINK
IN
SIG LINK
OUT
1
3
4
4
XTP
RS-232 IR
RS-232 IR
Tx Rx
Tx Rx
G
Tx Rx
Tx Rx
XTP
S/PDIF
OUT
DTP
XTP
DTP
XTP
DTP
HDBT
G
DTP
HDBT
2
1
2
3
4
5
8
6
RS-232 IR
Tx Rx
Tx Rx
G
OVER TP
OVER TP
INPUTS
OUTPUTS
RS-232 IR
Tx Rx
Tx Rx
G
Figure 5.
Serial and IR Insertion Connections
Over TP (Inputs 7 and 8) Ports
— Plug serial RS-232 signals, modulated IR
RS-232 IR
Tx Rx
Tx Rx
G
signals, or both into these 3.5 mm, 5-pole captive screw connectors to insert
bidirectional RS-232 and IR communications (see
to wire the connectors).
Over TP (Outputs 3 and 4) Ports
— Plug serial RS-232 signals, modulated IR
RS-232 IR
Tx Rx
Tx Rx
G
signals, or both into these 3.5 mm, 5-pole captive screw connectors to insert
bidirectional RS-232 and IR communications (see
to wire the connectors).
Control Connections
Tx Rx
RTS CTS
G
Tx Rx G Tx Rx G
LAN 2
LAN 1
LAN 3
R
CONTRO
L
1 2 3 4 G
DIGITAL I/O
COM 3
COM 2
COM 1
S
S
G
G
1
1
2
2
C
3 4 C
-S G
+S
+V
PWR OUT = 6W
IR/SERIAL
eBUS
RELAYS
Tx Rx G
REMOTE
LAN
Figure 6.
IPCP Control Processor and Remote Port
NOTE:
Figure 6 is a composite that shows features of all models. Specific models can
have
either
a LAN port (item
Q
, below)
or
a control processor (
on page 8),
but not both.
LAN (Ethernet) port
(non-IPCP model) — If desired, connect a network WAN or LAN hub,
a control system, or a computer to the Ethernet RJ-45 port (see
page 8 to wire the connector).
NOTE:
The factory default IP address is 192.168.254.254.
IPCP
control processor
(IPCP models)—(see
on page 4)The IPCP models
include a built-in control processor that can control and monitor a variety of external
devices. The IPCP offers RS-232 and IR-based control, relays, and digital I/O controls.
See the
IPCP Pro Series Setup Guide
, included with the switcher, to make all connections
and to configure and operate the IPCP control processor.
Remote Port
— Plug a serial RS-232 device into the matrix switcher via this
Tx Rx G
REMOTE
3.5 mm, 3-pole captive screw connector for remote control of the switcher
(see
on page 11 to wire the connector).
Switcher Reset
Switcher Reset button and LED
—
Init
iates four levels of For different
RESET
reset levels, press and hold the recessed button while the switcher is running or
while you power up the switcher.
See the
DTP CrossPoint 84 Series User Guide
.
Power
Power connector
— Plug the switcher into a grounded AC source.
5
Over TP (Inputs 7 and 8) Ports
Over TP (Outputs 3 and 4) Ports
6
LAN (Ethernet) port
I
PCP
control processor
Remote Port
Switcher Reset button and LED
Power connector