![Extron electronics CrossPoint 450 Plus 3248 HV User Manual Download Page 64](http://html.mh-extra.com/html/extron-electronics/crosspoint-450-plus-3248-hv/crosspoint-450-plus-3248-hv_user-manual_2456132064.webp)
Operation, cont’d
CrossPoint 450 Plus and MAV Plus Switchers • Operation
3-32
Muting and unmuting outputs
Individual outputs can be muted or unmuted as follows:
N
Mutes are protected when front panel
Lock
mode 2 is selected. You can view the
status of the output (muted or unmuted) in
Lock
mode 2 but you cannot change
it from the front panel. See “Setting the front panel Locks (
on page 3-43.
1
.
Press the Esc button to clear any input button indications, output button
indications, or control button indications that may be on.
2
.
Press and release the View button.
3
.
Select video, audio, or both to mute or unmute by pressing the RGBHV
(CrossPoint 450 Plus switchers) or Video (MAV Plus video switchers)
button and the Audio button.
4
.
One at a time
, press and
hold
the button(s) for the desired output(s) for
approximately 2 seconds. The output button(s) for the selected output(s)
blink to indicate the mute or return to their previous state to indicate the
unmute.
5
.
Press and release the View button to return to normal switcher operation.
N
• You can mute video and audio, video-only, or audio-only outputs. Pressing
and releasing the RGBHV (CrossPoint 450 Plus switchers) or Video (MAV
Plus video switchers) button and the Audio button toggles each selection on
and off.
• When you enter
View-only
mode, the output LEDs turn
on
for all outputs
without
ties.
• On CrossPoint 450 Plus switchers, the video mute function mutes the
wideband video switching BMEs (the R, G, and B planes) only; the sync
switching BMEs (the H and V planes) are still active. On MAV Plus low
resolution video switching BMEs, the video mute function mutes all video
planes.
• Mutes are saved to non-volatile memory. When power is removed and
restored, the mute settings are retained.
Example 9: Muting and unmuting an output
In the following example, several switcher outputs are muted and unmuted. The
steps show the front panel indications that result from your actions.
1
.
Clear all selections
:
Press and release the Esc button.
C O N T R O L
PRESET
ENTER
ESC
VIEW
Press the Esc button to clear all selections.
The button flashes once.
2
.
Enter
View-only
mode
: Press and release the View button to enter
View-only
mode. The View button lights red.
Summary of Contents for CrossPoint 450 Plus 3248 HV
Page 1: ...CrossPoint 450 Plus Series MAV Plus series Large Scale Matrix Switchers 68 521 03 Rev B 11 09 ...
Page 4: ......
Page 10: ...Table of Contents cont d CrossPoint 450 Plus and MAV Plus Switchers Table of Contents vi ...
Page 32: ...Installation cont d CrossPoint 450 Plus and MAV Plus Switchers Installation 2 14 ...
Page 86: ...Operation cont d CrossPoint 450 Plus and MAV Plus Switchers Operation 3 54 ...
Page 88: ...Operation cont d CrossPoint 450 Plus and MAV Plus Switchers Operation 3 56 ...
Page 112: ...Programmer s Guide cont d CrossPoint 450 Plus and MAV Plus Switchers Programmer s Guide 4 24 ...
Page 183: ...B 15 CrossPoint 450 Plus and MAV Plus Switchers Reference Information Button label blanks ...