background image

 

2

Annotator 401 • Setup Guide (Continued)

Step 6 — Connecting power

Plug in a standard IEC power cord from a 100 to 240 VAC, 50-60 Hz power source into this power receptacle (see 

figure 1

A

 on 

the previous page).

Front Panel Overview

ANNOTATOR 401

ANNOTATION GRAPHICS PROCESSOR

CONFIG

MENU

NEXT

500 mA

ADJUST

ANNOTATOR 401

100-240V      --A MAX 50-60Hz

LAN

USB EXT

RESET

PAIR

250 mA

1

2

3

REMOTE

DEVICES

OUTPUTS

INPUT

HDMI

1

HDMI

2

HDMI

RS-232

Tx Rx G

A B

C

D

E

A

B

D

E

C

F

G

H

I

Figure 2. 

Front Panel Overview

A

 

Front panel USB-C configuration port —

 Connect a computer to this USB-C port (cable not supplied), for device 

configuration, control, and firmware upgrading. 

B

 

Front panel USB-A port —

 Connect an external drive to store or recall captured images, or connect a user interface interface 

devices. 

C

 

LED display —

 This 16x2 screen displays device settings and menu configuration information. 

D

 

Menu navigation buttons (

MENU

 and 

NEXT

) —

 These buttons allow navigation through the LCD menu system of the 

Annotator 401. 

F

 

ADJUST

 

knobs —

 These are used with the menu navigation buttons to adjust the device settings and picture controls. 

Configuring the Annotator 401

The Annotator 401 can be configured either via front panel menus or through a host connected via RS-232, USB, or LAN 
connection. Through a host connection, the Annotator 401 can be configured using PCS, Toolbelt, embedded webpages, or SIS 
commands.

Front Panel Menu System

The scaler has a menu system consisting of seven submenus that can be accessed using the front panel 

Menu

 and 

Enter

 

buttons. The menus are:

Quick Setup • Picture Controls • Input Configuration • Output Configuration  

Image Capture/Recall• Advanced Configuration • View Comm Settings

To use any menu, press the 

MENU

 button to access the 

Quick

 

Setup

 menu, then repeatedly press the 

MENU

 button to cycle 

through the list to the desired menu. Press 

NEXT

 to enter the desired submenu, and continue the following steps.

NOTES:

  

• 

Press 

MENU

 at any time to exit a submenu and return to the main menu.

• 

For detailed information on the menus, see the 

Annotator 401 User Guide

, available at 

www.extron.com.

Configure the outputs, then the input, as follows:

1. 

Within the 

Output Configuration

 menu, use either 

ADJUST

 knob to configure the output resolution and refresh rate, the 

HDMI format, the 

HDCP

 

Notification

 (

Green

Black

, or 

User Image

), and the input 

AFL

TM

 

Accu-Rate

 

Frame

 

Lock

.

2. 

From the 

Test

 

Pattern

 menu, select the Alternating Pixels (Alt. Pixels) test pattern and view the display to confirm the 

display is sampling the signal properly.

3. 

From the 

Test

 

Pattern

 

menu, change the test pattern to 

Crop

, and adjust the display size, position, or overscan settings 

until all four sides of the crop pattern are visible. Set the test pattern to 

Off

 when done making adjustments to the display. 

4. 

Within the 

Input

 

Configuration

 menu, press the applicable input button, then press 

NEXT

 to cycle to the desired submenu.  

Rotate the 

ADJUST

 knobs to change the input settings (for example: 

Aspect

 

Ratio

EDID

HDCP Authorize

, or 

Auto

 

Memory

as required. 

 

Summary of Contents for Annotator 401

Page 1: ... E USB EXT RJ 45 connector F Pairing button and Status LED G Reset button and LED H RJ 45 LAN connector I RS 232 3 pole captive screw connector Installation Mounting and Cabling Step 1 Mounting optional a Turn off or disconnect all equipment power sources b Place the Annotator 401 on top of a flat surface using the provided rubber feet mount it under a table using an optional kit for under desk mo...

Page 2: ...System The scaler has a menu system consisting of seven submenus that can be accessed using the front panel Menu and Enter buttons The menus are Quick Setup Picture Controls Input Configuration Output Configuration Image Capture Recall Advanced Configuration View Comm Settings To use any menu press the MENU button to access the Quick Setup menu then repeatedly press the MENU button to cycle throug...

Page 3: ...USB driver may not support the panel and a custom USB module must be uploaded to the Annotator 401 using PCS Refer to Annotaton Settings in the Annotator 401 User Guide for more information Command and Response Table for SIS Commands NOTE The following table is a partial list of SIS commands and output resolutions For a complete listing of SIS commands see the Annotator 401 User Guide Command Name...

Page 4: ...aight line with an arrowhead Tools This opens a secondary palette with advanced tools Capture Freeze Mute Whiteboard Spotlight Zoom and Pan Rectangle This creates a rectangle with edges parallel to the raster Capture This takes a snapshot image of the current program output including annotations Captured images can be saved to the unit PC USB flash drive or network drive Ellipse This creates an el...

Reviews: