Extreme Networks ExtremeWireless WS-AP3965e-FCC Quick Reference Download Page 1

Installing the ExtremeWireless Outdoor 
AP3965 

Overview of the AP3965

The AP3965 enables you to extend your Wireless LAN 
beyond the boundaries of indoor locations. It is resistant to 
harsh outdoor conditions and extreme temperatures 
(Operating Temp. -40ºC~60ºC). Using the advanced 
wireless distribution mesh feature of Wireless LAN, the 
AP3965 can extend your Wireless LAN to outdoor locations 
without Ethernet cabling. Mounting brackets are provided 
for quick and easy mounting of the AP to walls and poles.

Figure 1  AP3965 Top View 

AP3965 models have the following specifications:
• Radios: 2 radios (2.4 GHz and 5 GHz)
• LEDs:  5  (see 

Figure 1

)

• Power: 802.3at (PoE+) compliant
• The AP3965 supports the 802.11ac and 802.11n wireless 

standards, with full backward compatibility with legacy 
802.11a, and 802.11b/g. The AP3965 with external antenna 
connectors supports a variety of antennas. (External 
antennas must be ordered separately.)

• The AP3965 interoperates fully with Wireless LAN, 

including support for VoWLAN, branch office mode, 
guest services, RTLS, availability and mobility features.

• Mounting brackets for a wall or pole mount
• Enabled for use with an ExtremeCloud

TM

 entitlement.

For detailed installation information about the AP3965, see 
the 

ExtremeWireless AP3965i/e Installation Guide

.

Electrical Hazard: 

Only qualified personnel should perform 

installation procedures.

Note: 

In this Quick Reference, any reference to 

AP3965

 

applies to both AP3965 an “i” model (with internal 

antennas) and an “e” model (with external antennas). 

1

Status

5

Radio 1 (5 GHz)

2

LAN 1 (Ethernet 1)

6

LAN Ports (POE):
LAN 1 PDE Port
LAN 2 PSE Port output of DC48V, 0.26A

3

LAN 2 (Ethernet 2)

7

Console Port and Reset Button

4

Radio 2 (2.4 GHz)

.

Warning: 

 Always install and torque all LAN and Console 

caps properly, regardless of installation site location.

Note: 

All radio and LAN ports are labeled on the AP3965.

Unpacking the AP3965

The AP3965 box includes a cardboard separation.
1 Unpack the AP3965 from its carton. 
2 Verify the contents of the carton as listed in 

Table 1

.

Optional:

 You may also need antennas, terminators, or 

cables. Refer to 

www.extremenetworks.com/support

 for 

product numbers.

Mounting the AP3965

Use these instructions as guidelines for mounting and 
connecting the AP3965 easily and safely. The installation of 
the AP3965 should be performed by a professional installer 
to ensure proper operation and compliance with local 
safety guidelines.
Attach the AP3965 to a surface that can support it and 
withstand its environment. It can be mounted to a wall, 
girder, ceiling, or pole, and the surface material can be 
concrete, brick, wood, metal, or plastic. 

Positioning the AP for Installation

Mount the AP so that the glands are on the side of the AP 
closest to the ground, and not above the plastic cover. You 
must provide a 3-inch drip loop on all cables. 

Attach the Ground Wire

Use the M4 ground screw assembly, with the star washer, to 
attach the ground wire’s ring terminal to the back of the AP. 
The wire should be as close to the AP bottom as possible. 
Tighten the screw to a torque of 12.0 in-lbs.

Mounting the AP3965 to a Wall

1 Using the mounting bracket as a guide, mark the location 

for the mounting screws. The wall bracket provides 8 
attachment holes. Use 4 (1 in each corner), Place the 
bracket and mark the 4 hole centers.

2 Drill four holes into the wall as follows:

– for installing the AP on a masonry wall, use a 5/16” diameter 

bit.

– for other materials, use the appropriate drill for the screws 

being used.

3 For masonry installations, drill at least 1/8” [3MM] past 

the depth of the screw, or bolt, being used, and place 
four anchor assemblies into the holes.

4 Attach the AP to the “H” Bracket:

Table 1 Contents of the AP3965 

Quantity

Item

1

AP3965 Quick Reference

1

WS-AP3965i/e model that you ordered.

Under the cardboard separation:

1

H” shaped bracket that is used for mounting the AP.

1

Metal bracket for attaching the AP to a pole, pipe, or mast.

1

#10AWG ground wire with a ring terminal crimped on it (6 foot 
length)

The following hardware is included: 

4

Additional hex nuts for the concrete anchors.

4

Concrete wall anchor assemblies that include the anchors, a 
flat washer, and a hex nut.

4

Split washer for the concrete anchors.

4

Cable clamps, all are ½" wide. Two clamps accommodate a 2.5" 
maximum diameter pole and two clamps accommodate a 
6”-7” diameter pole.

8

Screw assemblies, size M4, that include the screws, flat 
washers, and split washers.

1

Ground Screw assembly, size M4, that include the screw, star 
washer, and split washer.

Note: 

Before mounting the AP3965, read the “RF Safety 

Distance” on page 2.

a Use 4 M4 screw assemblies to attach the AP to the “H” 

bracket on the side that does 

not

 have the PEM stand-

offs. 

b Tighten the four screws to a torque of 12.0 in-lbs. 

5 Secure the anchors to the wall, then secure the bracket 

to the anchors.

6 If using #10 screws, tighten them to a torque of 25 in-lbs. 

If using ¼” screws, tighten them to 45 in-lbs.

Figure 2

 AP3965 Wall Mount “H” Bracket

Mounting the AP3965 to a Pole

1 Determine the diameter of the pole. 

For other pole diameters, provide your own stainless steel 
cable clamp. The band must be ½” [12.7mm] wide.

2 Attach the AP to the “H” bracket on the side that does 

not have the PEM stand-offs. Tighten the four screws to a 
torque of 12.0 in-lbs. 

3 Using four M4 screw assemblies, attach the pole bracket 

onto the “H” bracket. Tighten the screws to 12.0 in-lbs.

Figure 3

 Attaching Pole Mount to “H” Bracket

4 Attach the cable clamp to the pole bracket. Open the 

cable clamp by turning a flat bladed screwdriver 
counterclockwise. Then, insert the non-clamp end into 
the pole bracket through the holes.

Pole Diameter

Cable Clamp Size

<= 2.5” [63.5mm],

Use small cable clamp.

6” - 7” (178mm)

Use large cable clamp

Note: 

It is easier to install both clamps before attaching to 

the pole.

5 Put the metal band around the pole and insert it into the 

clamp. Turn the clamp screw clockwise, tightening the 
band around the pole. 

Figure 4  AP with Mounting Bracket—Horizontal Position

Figure 5  AP3965 Pole Mount—Vertical Pole

Installing External Antennas

1 Professionally install the external antennas intended for 

area coverage. For information about antenna selection 
and installation, refer to the 

External Antenna Site 

Preparation and Installation Guide

2 Attach the external antenna cables to the Standard 

Polarity Type-N connectors on the AP3965.

Connecting & Powering the AP3965

You can power up the AP3965 using Power over Ethernet 
based on 802.3at (PoE+) compliant switch or PoE+ injector.
• The PoE injector must be 802.3at compliant. The PoE 

injector is not provided with the AP. 

• A waterproof RJ45 connector is provided to connect the 

PoE injector to the AP3965. You must connect the RJ45 
connector to the RJ45 cable. For instructions, refer to 
the 

ExtremeWireless Outdoor 

AP3965

 Installation Guide

.

Note: 

When the AP3965 is powered by the Power Injector, 

the DATA port of the Injector should be connected to a non 
PoE switch or, if the switch is PoE capable, PoE must be 
DISABLED on the DATA port.