background image

Extreme Portal

Search the GTAC (Global Technical Assistance Center) knowledge base, manage support cases and service
contracts, download software, and obtain product licensing, training, and certifications.

The Hub

A forum for Extreme Networks customers to connect with one another, answer questions, and share ideas and
feedback. This community is monitored by Extreme Networks employees, but is not intended to replace specific
guidance from GTAC.

Call GTAC

For immediate support: 1-800-998-2408 (toll-free in U.S. and Canada) or +1 408-579-2826. For the support
phone number in your country, visit: 

www.extremenetworks.com/support/contact

Before contacting Extreme Networks for technical support, have the following information ready:

Your Extreme Networks service contract number and/or serial numbers for all involved Extreme Networks products

A description of the failure

A description of any action(s) already taken to resolve the problem

A description of your network environment (such as layout, cable type, other relevant environmental information)

Network load at the time of trouble (if known)

The device history (for example, if you have returned the device before, or if this is a recurring problem)

Any related RMA (Return Material Authorization) numbers

Subscribing to Service Notifications

You can subscribe to email notifications for product and software release announcements, Vulnerability Notices, and Service
Notifications.

1. Go to 

www.extremenetworks.com/support/service-notification-form

.

2. Complete the form with your information (all fields are required).

3. Select the products for which you would like to receive notifications.

NOTE

You can modify your product selections or unsubscribe at any time.

4. Click 

Submit

.

Providing Feedback to Us

Quality is our first concern at Extreme Networks, and we have made every effort to ensure the accuracy and completeness of this
document. We are always striving to improve our documentation and help you work better, so we want to hear from you! We welcome all
feedback but especially want to know about:

Content errors or confusing or conflicting information.

Ideas for improvements to our documentation so you can find the information you need faster.

Broken links or usability issues.

If you would like to provide feedback to the Extreme Networks Information Development team, you can do so in two ways:

Use our short online feedback form at 

https://www.extremenetworks.com/documentation-feedback/

.

Email us a

[email protected]

.

Please provide the publication title, part number, and as much detail as possible, including the topic heading and page number if
applicable, as well as your suggestions for improvement.

Providing Feedback to Us

ExtremeRouting SLX 9850-4 Hardware Installation Guide

9035474-02 Rev AA

9

Summary of Contents for ExtremeRouting SLX 9850-4

Page 1: ...HARDWARE INSTALLATION GUIDE ExtremeRouting SLX 9850 4 Hardware Installation Guide 9035474 02 Rev AA June 2019...

Page 2: ...are trademarks or registered trademarks of Extreme Networks Inc in the United States and or other countries All other names including any product names mentioned in this document are the property of...

Page 3: ...al precautions 23 ESD precautions 23 Lifting precautions 24 Laser precautions 24 Facility requirements 24 Time and items required for installation 25 Quick installation checklists 26 Pre installation...

Page 4: ...nitoring Overview 75 Interpreting management module LEDs 75 Interpreting interface module LEDs 77 Interpreting power supply module LEDs 80 Interpreting fan module LEDs 83 Interpreting switch fabric mo...

Page 5: ...h Fabric Modules 119 Switch fabric module overview 119 Precautions specific to the switch fabric module 120 Time and items required for replacement 121 Removing a switch fabric module 121 Inserting a...

Page 6: ...C 144 Regulatory compliance safety 144 Regulatory compliance environmental 144 Regulatory Statements 147 BSMI statement Taiwan 147 Canadian requirements 147 CE statement 147 China ROHS 148 FCC warning...

Page 7: ...n traffic might be interrupted or the device might reboot CAUTION A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware firmware software or...

Page 8: ...and examples If a backslash separates two lines of a command input enter the entire command at the prompt without the backslash Documentation and Training To find Extreme Networks product guides visit...

Page 9: ...ns You can subscribe to email notifications for product and software release announcements Vulnerability Notices and Service Notifications 1 Go to www extremenetworks com support service notification...

Page 10: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 10 9035474 02 Rev AA...

Page 11: ...OS 16r 1 00 Yes TABLE 2 SLX 9850 4chassis bundles Part number Long description Introduced OS Currently supported BR SLX9850 4 BND AC SLX 9850 4 slot chassis with 1 management module 5 switch fabric m...

Page 12: ...re versions specified below Auto Level Support Table 1 Auto Level Support 32 bit Linecard LC 64 bit Linecard LC 17r 101a or lower 17r 1 01b 17r 2 00 or higher 32 bit Mgmt Module MM 17r 101a or lower S...

Page 13: ...pports 750K MAC 256K IPv4 64K IPv6 routes SLX OS 16r 1 01 Yes BR SLX9850 100Gx36CQ M SLX 9850 36 port 100 GbE 60 port 40 GbE or 240 port 10 GbE flex speed M interface module with IPv4 IPv6 MPLS hardwa...

Page 14: ...le 10m 1 pack SLX OS 16r 1 00 Yes 40G QSFP QSFP C 0101 4x10GE Direct Attached QSFP to 4 SFP Active Copper Breakout Cable 1m 1 pack SLX OS 16r 1 00 Yes 40G QSFP 4SFP C 0301 4x10GE Direct Attached QSFP...

Page 15: ...uld only be connected to an E1MG BXU at the far end SLX OS 16r 1 00 Yes E1MG BXU 1000Base BXU SFP optic SMF transmits at 1310nm and receives at 1490nm LC connector single strand SMF fiber This optic s...

Page 16: ...post rack mounting kit for 4 slot chassis Includes Telco flush and midplane mounting TABLE 13 SLX 9850 4 cable management kit Part number Long description XBR SLX9850 4 CAB SLX 9850 Cable Management...

Page 17: ...e is located at the top of the chassis The following figure shows the device slot numbering and port side view of the SLX 9850 4 The call outs in the figure correspond to the numbering of each router...

Page 18: ...pply slot 2 9 Power supply slot 3 10 Power supply slot 4 11 Power supply slot 5 12 Power supply slot 6 Device slot numbering nonport side The following figure shows the nonport side view of the SLX 98...

Page 19: ...abric modules are located behind the fans There are six slots for the switch fabric modules Numbering for the modules goes from left to right with 1 on the far left and 6 on the far right Device slot...

Page 20: ...6 Device management options Use the serial ports to manage your device The serial ports are located on the management module The following figure shows the serial console ports Use the console port fo...

Page 21: ...1 Service Ethernet port 10G 1G 100M 2 Auxiliary console port 3 USB port 4 USB port 5 Console port 6 Management Ethernet port 1G 100M 10M Device management options ExtremeRouting SLX 9850 4 Hardware I...

Page 22: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 22 9035474 02 Rev AA...

Page 23: ...re beginning the installation see the precautions in Power precautions CAUTION Changes or modifications made to this device that are not expressly approved by the party responsible for compliance coul...

Page 24: ...ions on page 137 Electrical Ensure that there are dedicated electrical branch circuits with the following characteristics Protected by a circuit breaker in accordance with local electrical codes Suppl...

Page 25: ...your device fully populated with the required interface modules refer to the ExtremeRouting SLX 9850 Technical Specifications on page 137 Installing rack mount kit 30 minutes Refer to instructions in...

Page 26: ...tiple devices TABLE 16 Installation prerequisites Task Task details or additional information Completed Unpack the device Unpack the device as shown in the Unpacking the shipping carton on page 28 Tak...

Page 27: ...the chassis virtual ip or chassis virtual ipv6 command to configure an IP address For more information refer to Configuring a static IP address on page 66 Establish an Ethernet connection By establis...

Page 28: ...install your device The device is packaged in a cardboard box with foam packing on a wooden pallet 1 Cut the bands that encircle the packing carton a Unpack the device b Leave the device on top of th...

Page 29: ...ules are packaged separately while the switch fabric modules are shipped inside the chassis Packing foam Antistatic plastic An accessory kit containing the following items A serial cable ESD wrist str...

Page 30: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 30 9035474 02 Rev AA...

Page 31: ...eview the Safety Precautions before mounting the device Mounting safety precautions The following precautions specifically apply to mounting the device DANGER Mount the devices you install in a rack a...

Page 32: ...find the weight of your device fully populated with the required interface modules refer to the ExtremeRouting SLX 9850 Technical Specifications on page 137 Device surface preparation All surfaces on...

Page 33: ...ght rail assembly 1 5 Screw 8 32 x 312 in flathead 6 Screw M6x1 0x12 in square cone 7 Screw 10 32 x 63 in square cone 8 Screw 8 32 x 375 in patch lock 9 Nut retainer 10 Washer 11 Nut clip floating Ins...

Page 34: ...post rack has rectangular unthreaded holes use 16 screws 16 nuts and 16 alignment washers from the rack mount kit to attach the kit to the posts 2 Prepare the device for mounting by attaching the lif...

Page 35: ...it in the four post rack ensuring that it remains supported during the transfer FIGURE 6 Installing the two rails from the rack mount kit Installing a device on a four post rack ExtremeRouting SLX 985...

Page 36: ...FIGURE 7 Installing the rack mount kit to the four post rack Installing a device on a four post rack ExtremeRouting SLX 9850 4 Hardware Installation Guide 36 9035474 02 Rev AA...

Page 37: ...ates from the recessed mount kit 1 Install the two rails from the rack mount kit for the four post rack with the rails perpendicular to the aisle 16 fasteners are required 4 for each post If the four...

Page 38: ...nting by attaching the lift to the device chassis 5 Using the lift raise the device to the correct level 6 If applicable lock the wheels of the lift 7 Ensure that the device is oriented so that the fr...

Page 39: ...ric modules interface modules switch fabric modules fan modules and power supply modules that have not already been installed Installing a device on a two post rack Use part number XBR SLX9850 4 2PRM...

Page 40: ...1 Left ear bracket 2 Right ear bracket 3 Saddle 4 Screw 8 32 x 312 in flathead 5 Screw 10 32 x 63 in square cone 6 Nut retainer Installing a device on a two post rack ExtremeRouting SLX 9850 4 Hardwar...

Page 41: ...t washers from the rack mount kit to attach the saddle to the posts FIGURE 12 Installing the saddle onto the two post rack 2 Remove the two side plates on the front port side of the chassis 3 Attach t...

Page 42: ...device until it rests on the saddles 9 Attach the device to the two posts of the rack using 6 screws 3 on each side FIGURE 13 Attaching the device to the rack 10 Install any device modules management...

Page 43: ...ount kit to attach the saddles to the posts 2 Remove the two side plates on the front port side of the chassis 3 Attach the larger side plates from the mid mount kit using 16 screws 8 per side FIGURE...

Page 44: ...pply modules that have not already been installed Installing an SLX 9850 4 NEBS kit Use the following instructions to install the SLX 9850 NEBS two post rack kit with a mid mount Use this kit XBR SLX9...

Page 45: ...e comb assembly 1 3 Air filter 1 4 Chassis door 1 5 Velcro strap 8 6 Screw 10 32 x 63 in square cone washer 10 7 Screw 8 32 x 312 in flathead 20 8 Nut retainer 6 Installing an SLX 9850 4 NEBS kit Extr...

Page 46: ...ting the NEBS kit installation the bezel needs to be removed FIGURE 17 Chassis installed on 2 post mid mount rack with bezel Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Instal...

Page 47: ...t holds the bezel to be removed prior to starting NEBS kit installation FIGURE 18 Bezel screws to be removed 1 Screw Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Installation G...

Page 48: ...3 Remove the 6 screws FIGURE 19 Removing the screws holding the bezel Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Installation Guide 48 9035474 02 Rev AA...

Page 49: ...ate the position where the six ball studs will be installed FIGURE 20 Ball studs to be installed Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Installation Guide 9035474 02 Rev...

Page 50: ...tall the 6 ball studs using a 1 4 Hex socket driver FIGURE 21 Ball studs installed 1 Ball studs Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Installation Guide 50 9035474 02 Re...

Page 51: ...e left cable comb assembly and the right cable comb assembly FIGURE 22 Installing cable comb assemblies Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Installation Guide 9035474...

Page 52: ...ent washers from the rack mount kit to attach the cable combs to the posts FIGURE 23 Cable comb assemblies installed 1 Screw Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Instal...

Page 53: ...8 Snap the door onto chassis ball studs FIGURE 24 Installing the chassis door Installing an SLX 9850 4 NEBS kit ExtremeRouting SLX 9850 4 Hardware Installation Guide 9035474 02 Rev AA 53...

Page 54: ...ble management combs You can install the cable management combs shipped with the chassis without service interruption for simple cable management If installing cable management combs remove the chassi...

Page 55: ...4 chassis For more information about cable management refer to the Managing cables on page 127 under the Transceivers and cables section of this guide Installing cable management combs ExtremeRouting...

Page 56: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 56 9035474 02 Rev AA...

Page 57: ...lish an Ethernet connection By establishing an Ethernet connection you can complete the device configuration using a serial or Telnet session Refer to Establishing an Ethernet connection on page 68 fo...

Page 58: ...vice The device mounted and installed with the required interface modules FRUs transceivers and cables and connected to a power source A workstation computer with an installed terminal emulator applic...

Page 59: ...C cord to the power supply module complete the following steps 1 Attach the chassis ground lug to the chassis ground 1 Chassis ground lug Providing power to the device ExtremeRouting SLX 9850 4 Hardwa...

Page 60: ...upply 1 Power supply receptacle 3 Route the cable so it will be out of the way when connected to the power source 4 Plug the other end of the cable into the power source Providing power to the device...

Page 61: ...1 50 shrink ratio Nominal recommended wall thickness 30480 mm 012 in minimum Dielectric strength 800V mil Tensile strength Greater than or equal to 5000 psi Operating temperature 40 C to 150 C 40 F t...

Page 62: ...eat shrink tubing 2 Power lug 9 Connect the power lugs to the power supply module Connect the 48V wire to the negative terminal and the 0V wire to the positive terminal NOTE The DC return must be isol...

Page 63: ...on the enclosure Before crimping the ground wire into the provided ground lug ensure the bare copper wire has been cleaned and antioxidant is applied to the bare wire To ensure adequate bonding when...

Page 64: ...0M 2 Auxiliary console port 3 USB port 4 USB port 5 Console port 6 Management Ethernet port 1G 100M 10M NOTE The console or serial port is intended primarily for the initial setting of the IP address...

Page 65: ...asswords for switch default accounts now Use Control C to exit or press Enter key to proceed 7 Press Enter to step through a procedure to change the passwords as shown in the following example To skip...

Page 66: ...ddress dhcp device config Management 1 ip address 10 24 85 81 20 5 Return to privileged EXEC mode by entering exit device config exit device 6 To display the configuration use the show running config...

Page 67: ...Time 23 08 49 GMT SLX OS Version 17r 1 00 Jumbo Capable yes Burned In MAC MM1 60 9c 9f 46 e2 06 MM2 60 9c 9f 47 10 7a Management IP 10 25 101 4 Management Port Status UP The MAC addresses are used to...

Page 68: ...0 0000 0000 0000 0000 Remove the host portion of the address based on a 64 netmask 2001 0DB8 0000 0000 Contract the remaining portion of the address of any leading zeros 2001 DB8 f Combine the IPv6 ne...

Page 69: ...g in to the device through a Telnet or SSH session using the chassis management IP address and admin login Customizing the chassis and host names To configure a chassis and host name complete the foll...

Page 70: ...uminated in blue A Telnet session using the chassis management IP address 2 Log in to the device using admin as your login name If you have not changed the default password use password for password 3...

Page 71: ...work current it is recommended that each device has its time synchronized with at least one external NTP server The device maintains the current clock server value in nonvolatile memory By default thi...

Page 72: ...onfig clock timezone America Los_Angeles Verifying correct operation Perform the following steps to verify correct operation of the device 1 Check the LEDs of all power supplies fans and modules to ve...

Page 73: ...ice using one of the following methods A serial console connection to the active management module The active management module has the LED labeled ACTIVE on the front panel illuminated in blue A comm...

Page 74: ...oad command are blocked on this device until the device is rebooted The device also informs its HA peer to shut down its database gracefully and not handle any database requests moving forward The dev...

Page 75: ...ption of the operations that the device performs when you power it on The following commands can be especially helpful in monitoring the health status of various device components For details about th...

Page 76: ...the show slots command If the LED remains amber consult the device supplier Green Module is powered on No action is required Power No light LED is off Module is not powered on Ensure that the module...

Page 77: ...gh port No action is required No light LED is off Port has no incoming power or there is no light or signal carrier detected Verify that the power LED is on Check the transceiver and cable Connected d...

Page 78: ...three rows of Ethernet ports FIGURE 35 Interface module port LEDs used for the 72 port 10GbE 1GbE interface module and similar for the other half of the flex speed interface module ports 1 LED for th...

Page 79: ...r on linecard slot_number command to make sure that the module is powered on in software Amber Module is faulty or initializing Check the module status by entering the show slots command If the LED re...

Page 80: ...required Green steadily blinking on and off for two seconds at a time A local fault has been detected Local fault detection can be confirmed with CLI flex cli show local fault To clear LED in this st...

Page 81: ...FIGURE 37 AC Power supply module LEDs 1 LED 1 AC in good 2 LED 2 AC out good Interpreting power supply module LEDs ExtremeRouting SLX 9850 4 Hardware Installation Guide 9035474 02 Rev AA 81...

Page 82: ...t the power supply is firmly seated the power cable is connected and that the power cable is connected to a power source Disconnect the power cable from the power supply remove and reinsert the power...

Page 83: ...D Top LED power Bottom LED status NOTE There are two sets of LEDs one for the fan and one for the switch fabric module SFM This table describes both sets of LEDs TABLE 23 Fan module LED descriptions L...

Page 84: ...ing the show slots command If LED remains amber consult the device supplier Green Module is operational No action is required Interpreting switch fabric module LEDs Refer to the following illustration...

Page 85: ...s powered off it does not indicate a problem on the device TABLE 24 SFM LED descriptions LED purpose Color Status Recommended action Power No light LED is off Module is not powered on Ensure that the...

Page 86: ...re tightened Amber Module is faulty or initializing Check the module status by entering the show slots command If LED remains amber consult the device supplier Green Module is operational No action is...

Page 87: ...t management module works in conjunction with the active management module If the active module becomes unavailable the redundant management module automatically takes over the system operation minimi...

Page 88: ...other electronic devices To avoid damage keep static sensitive devices in their static protective packages until you are ready to install them CAUTION The 1GbE Management Port is suitable for connecti...

Page 89: ...FIGURE 42 ESD ground strap chassis connection front 1 ESD ground strap connection point ESD ground strap connection points ExtremeRouting SLX 9850 4 Hardware Installation Guide 9035474 02 Rev AA 89...

Page 90: ...replacement procedure for the management module takes approximately 30 minutes The following items are required for the management module replacement ESD grounding strap Workstation or laptop compute...

Page 91: ...dule is being replaced if the redundant management module is installed and initialized Complete the following steps to remove a management module Refer to the illustration provided with the procedure...

Page 92: ...ment module Refer to Precautions specific to the management modules on page 88 before replacing a management module Complete the following steps to insert a management module Refer to the illustration...

Page 93: ...wer and is firmly seated and that the ejectors are in the locked position 10 Reconnect any cables that were attached to the old module Verifying management module operation To verify proper operation...

Page 94: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 94 9035474 02 Rev AA...

Page 95: ...erface modules supported for the SLX 9850 36 port 100GbE 60 port 40GbE or 240 port 10GbE flex speed interface module 72 port 10GbE 1GbE interface module The following figure shows the front panel of t...

Page 96: ...turn off the blinking LEDs enter the chassis beacon disable command FIGURE 47 Port numbering for the flex speed module when port speed is set to 100GbE The following figure shows the front panel of th...

Page 97: ...tion from dust The line cards are sensitive to electrostatic discharge ESD When working with any Extreme module use correct electrostatic discharge ESD procedures Wear a wrist grounding strap connecte...

Page 98: ...f multiple line cards in chassis slots it is recommended to install the blades from the bottom to the top Using this procedure the last blade to be installed would be LC 1 NOTE When handling or liftin...

Page 99: ...e module in the slot 9 Tighten the captive screws using the 2 Phillips screwdriver NOTE The interface module will not function unless the captive screws are tightened 10 Install the transceivers and c...

Page 100: ...iginal interface module from the chassis database by following these steps a Enter the configure terminal command to enter global configuration mode b Enter the no linecard slot_number command This co...

Page 101: ...rpreting interface module LEDs on page 77 2 Enter the following commands and note any error conditions show linecard Displays the current status of each interface module show system Displays informati...

Page 102: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 102 9035474 02 Rev AA...

Page 103: ...ing replacement if procedures are followed in this guide NOTE Depending on the module configuration of the chassis and the number of power supplies installed the device may be able to continue operati...

Page 104: ...LED 2 DC Out LED 3 AC power cable receptacle 4 Handle 5 Securing latch The following figure shows the components of the DC power supply Power supply module overview ExtremeRouting SLX 9850 4 Hardware...

Page 105: ...AC and DC power supplies and High Voltage AC and High Voltage DC PSU refer to ExtremeRouting SLX 9850 Technical Specifications on page 137 Power cables are not supplied with the SLX 9850 devices Powe...

Page 106: ...eplacement procedure for each power supply takes less than 5 minutes The following items are required for the power supply replacement New power supply unit or filler panel 2 Phillips screwdriver Remo...

Page 107: ...URE 53 AC power supply 1 Power supply AC connector 3 Lift the latch on the lower part of the power supply to release the power supply from the chassis Removing an AC power supply module ExtremeRouting...

Page 108: ...to the illustration provided with the procedure 1 Unpack the new power supply and remove it from the anti static bag 2 Inspect the power supply for damage 3 Insert the power supply into the slot 4 Ma...

Page 109: ...the power lugs FIGURE 55 DC power supply lugs 1 Power lug 2 Power lug 4 Depress the latch on the lower part of the power supply to release the power supply from the chassis 5 Grasp the handle and pull...

Page 110: ...tatus of the power supply show system Displays information of each component in the system High Voltage Power Supply Unit supporting AC and DC Voltages The SLX 9850 4 supports High Voltage Power Suppl...

Page 111: ...LED for status indication of PSU The table below indicates the status LED color and their meaning TABLE 27 HV PSU Status LED Definitions Type LED Definitions Power supply LEDs LED 1 and LED 2 Steady G...

Page 112: ...n Power Products as described in the connector type section High Voltage input power is provided to the chassis by means of up to 6 detachable power cords for F4 and up to 12 detachable line cords for...

Page 113: ...s not supported NOTE HV PSUs will be supported only on build to order base chassis SKU namely Fusion Chassis P Ns These offerings do not include PSUs or Fans PSUs and Fans must be added based on the c...

Page 114: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 114 9035474 02 Rev AA...

Page 115: ...over temperature condition it automatically sends a warning message When the critical temperature is reached the system shuts down NOTE The ambient intake temperature of the system must be less than 3...

Page 116: ...lt LEDs should be unlit 2 Use the screwdriver to loosen the four captive screws at the top and bottom of the fan NOTE The fan needs to be replaced within 2 minutes if the ambient temperature exceeds 3...

Page 117: ...ror conditions Air filter replacement schedule The air filter is only used with systems that include a NEBS kit for NEBS compliance You can remove and replace an air filter when it gets too clogged wi...

Page 118: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 118 9035474 02 Rev AA...

Page 119: ...ely fail If an SFM fails the SFM LED on the management module and fan module displays amber showing which SFM has failed and a syslog message is created System traffic is automatically is re balanced...

Page 120: ...nt intake temperature of the system must be less than 35 deg C 95 deg F at sea level to prevent overheating If the ambient temperature is greater than 35 deg C the module installation time must be red...

Page 121: ...o be removed by performing one or both of the following steps Refer to the sticker on the rear of the chassis below the fans that provides a graphic representation of the SFMs behind each fan module F...

Page 122: ...placed within 2 minutes if the ambient temperature exceeds 35 deg C 95 deg F Inserting a switch fabric module Complete the following steps to insert the switch fabric module SFM similar to the procedu...

Page 123: ...r to insure the ejector is held in the closed position the user may need to hold the ejector down by hand during operation or turning the thumbscrew NOTE The SFM will not function unless the captive s...

Page 124: ...k SFM status For information about interpreting LED patterns refer to Interpreting switch fabric module LEDs on page 84 2 Enter the following commands and note any error conditions show chassis show s...

Page 125: ...current information about transceivers and cables that is supported by this ExtremeRouting SLX 9850 device refer to the Extreme Ethernet Optics Family Datasheet on https cloud kapostcontent net pub a...

Page 126: ...ION Before plugging a cable into any port be sure to discharge the voltage stored on the cable by touching the electrical contacts to ground surface Cleaning the fiber optic connectors To avoid proble...

Page 127: ...y from the LEDs Do not route the cables in front of air vents Use Velcro type straps to secure and organize fiber optic cables Route the cables away from LEDs to keep them visible Use the cable manage...

Page 128: ...ing mechanism clicks FIGURE 62 Installing an SFP transceiver with pull tab into the interface module port 1 Pull tab 2 Transceiver If the transceiver uses a bail latch mechanism 10 GbE transceivers on...

Page 129: ...ceiver until the latching mechanism clicks NOTE Cables are keyed so that they can be inserted in only one way If a cable does not slide in easily ensure that it is correctly oriented Do not insert any...

Page 130: ...tly using the bail and then gasp the transceiver with your fingers and slide it straight out of the port FIGURE 64 Installing an SFP transceiver with bail latch into the interface module port 1 Bail I...

Page 131: ...igned with the slot in the transceiver Insert the cable into the transceiver until the latching mechanism clicks Cables are keyed so that they can be inserted in only one way If a cable does not slide...

Page 132: ...Rapid flash link with traffic Slow flash one second on one second off beaconing feature 2 Position the cable so that the key the ridge on one side of the cable connector is aligned with the slot in t...

Page 133: ...ng the transceiver body 3 To insert the replacement transceiver use the pull tab to carefully push the transceiver into the port Transceivers are keyed so that they can only be inserted with the corre...

Page 134: ...R4 INT and 40G QSFP ESR4 optics for use with fiber breakout cables The copper breakout cables are terminated with optical connectors and are available in 1m 3m 5m and greater lengths No additional con...

Page 135: ...n also replace the following hardware components as needed All modules management interface and switch fabric modules Fiber optic transceivers AC power supply modules AC or DC power supply modules Fan...

Page 136: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 136 9035474 02 Rev AA...

Page 137: ...le 8 maximum Switch fabric module SFM 6 maximum Management modules MM 2 maximum Power supply assemblies 12 maximum Fan assemblies 3 maximum Power inlet C20 power from port side Power supplies SLX 9850...

Page 138: ...ch fabric module OK Amber error Off Unexpected error Ethernet Green Solid Link is up Green Blinking Link is up and running traffic Off No link Amber some flex module ports module is in 100G mode and t...

Page 139: ...including two management modules six switch fabric modules three fans four power supplies and two cable management combs Model Height Width Depth Weight empty Weight fully loaded SLX 9850 4 10 rack un...

Page 140: ...terface module part number BR SLX9850 100Gx3 6CQ M Interface module with 36 100GbE ports requires QSFP28 optics 40GbE ports requires QSFP optics or 240 10GbE ports requires 40GbE to 10GbE breakout 64...

Page 141: ...e cards are enabled and optics Traffic are at 50 line rate Random packets fans at nominal speed ambient temperature 25 deg C Configuration of SLX 9850 8 One 8 slot chassis with one management module f...

Page 142: ...amps watts and BTU hr are calculated with 0 98 power factor and 4 PSUs Power consumption modules typical configuration NOTE Typical configuration is 50 traffic with fans operating normally Ambient te...

Page 143: ...40GbE or 240 port 10GbE flex speed interface modules SLX 9850 8 1 GbE 576 Supports up to 576 1 GbE ports with eight 72 port 10GbE 1GbE interface modules 10 GbE 576 Supports up to 576 1 GbE ports with...

Page 144: ...mark Immunity for Information Technology Equipment ICES 003 Canada Class A AS NZ 55022 Australia Class A VCCI Japan Class A EN 61000 3 2 EN 61000 3 3 EN 61000 6 1 Regulatory compliance safety CAN CSA...

Page 145: ...n and Restriction of Chemicals EU REACH Section 1502 of the Dodd Frank Wall Street Reform and Consumer Protection Act of 2010 U S Conflict Minerals 30 2011 TT BCT Vietnam circular SJ T 11363 2006 Requ...

Page 146: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 146 9035474 02 Rev AA...

Page 147: ...of the Canadian Interference Causing Equipment Regulations ICES 003 Class A Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada CE statement ATTENTION This is a Class A produ...

Page 148: ...nstruction manual might cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be requ...

Page 149: ...is used in a domestic environment radio disturbance might arise When such trouble occurs the user might be required to take corrective actions Japan power cord English translation of above statement A...

Page 150: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 150 9035474 02 Rev AA...

Page 151: ...ment PRECAUCI N Si se realizan cambios o modificaciones en este dispositivo sin la autorizaci n expresa de la parte responsable del cumplimiento de las normas la licencia del usuario para operar este...

Page 152: ...und wire should have an agency approved crimped connector provided with the device attached to one end with the other end attached to building ground The connector must be crimped with the proper tool...

Page 153: ...sa ubicaci n CAUTION All devices with DC power supplies are intended for installation in restricted access areas only A restricted access area is a location where access can be gained only by trained...

Page 154: ...use the port cover tabs to lift the module They are not designed to support the weight of the module which can fall and be damaged VORSICHT Verwenden Sie nicht die Laschen der Anschlussabdeckungen um...

Page 155: ...a DANGER Do not attempt to lift the Extreme Networks chassis It is extremely heavy Use a mechanical lifting device to lift the chassis Four or more people are required to position the unpopulated chas...

Page 156: ...das las fuentes de corriente DANGER High Touch Current Earth connection essential before connecting supply GEFAHR Hoher Ableitstrom Vor Anschluss ans Netz Schutzerdung herstellen DANGER Courant de fui...

Page 157: ...ique de retenue des c bles qui se trouve sous l entr e d alimentation haute tension retirez les 2 vis Torx PELIGRO Para remover la cubierta metalica de protecion debajo de la entrada de la fuente de a...

Page 158: ...n in den Laserstrahl herein Klasse 1M Laserprodukte DANGER Rayonnement de laser Ne regardez pas directement avec des instruments optiques Produits de laser de classe 1M PELIGRO Radiacion de Laser No v...

Reviews: