DANGER
For safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor.
Time and items required for replacement
The replacement procedure for the switch fabric module takes approximately 15 minutes (5 minutes to remove the fan module, and 10
minutes to remove the switch fabric module. Extreme recommends replacement to approximately 20 minutes to include inserting the
replacement switch fabric module.
The following items are required for the switch fabric module replacement:
•
ESD grounding strap
•
#2 Phillips screwdriver
•
Replacement switch fabric module
NOTE
The ambient intake temperature of the system must be less than 35 deg C (95 deg F) at sea level to prevent overheating. If the
ambient temperature is greater than 35 deg C, the module installation time must be reduced. Refer to the specific module
removal and installation instructions in this guide for more details.
Removing a switch fabric module
You can continue to operate the device while a switch fabric module (SFM) is being replaced.
Complete the following steps to remove an SFM. Refer to the illustration provided with the procedure.
1. Determine which fan module needs to be removed by performing one or both of the following steps.
•
Refer to the sticker on the rear of the chassis, below the fans, that provides a graphic representation of the SFMs behind
each fan module.
•
Find the fan module that has the SFM Fault LED lit, and remove this fan module.
2. Remove the fan module to access the SFM. Refer to
on page 116 for this procedure.
NOTE
The fan needs to be replaced within 2 minutes if the ambient temperature exceeds 35 deg C (95 deg F).
3. Unscrew the two captive screws on the top and the bottom of the SFM using the #2 Phillips screwdriver.
•
The use of a long handled #2 Phillips screwdriver is recommended although not required.
•
While operating or turning the thumbscrew on SFMs during installation and removal of the blade, insure that the ejector is
held in the closed position. This insures ease of operation of the thumbscrew and insures that the screw is either fully
seated while installing or is fully disengaged while removing the blade. In order to insure the ejector is held in the closed
position, the user may need to hold the ejector down by hand during operation or turning the thumbscrew.
4. Open the ejectors on the top and bottom of the SFM by rotating them outward towards you.
Removing a switch fabric module
ExtremeRouting SLX 9850-4 Hardware Installation Guide
9035474-02 Rev AA
121
Summary of Contents for ExtremeRouting SLX 9850-4
Page 10: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 10 9035474 02 Rev AA...
Page 22: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 22 9035474 02 Rev AA...
Page 30: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 30 9035474 02 Rev AA...
Page 56: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 56 9035474 02 Rev AA...
Page 94: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 94 9035474 02 Rev AA...
Page 102: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 102 9035474 02 Rev AA...
Page 114: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 114 9035474 02 Rev AA...
Page 118: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 118 9035474 02 Rev AA...
Page 136: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 136 9035474 02 Rev AA...
Page 146: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 146 9035474 02 Rev AA...
Page 150: ...ExtremeRouting SLX 9850 4 Hardware Installation Guide 150 9035474 02 Rev AA...