ENGLISH
alaRMs
Display
explanation
solution
Indicates the presence of an alarm.
On: indicates the presence of an alarm
Off: indicates the absence of alarms
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset by pressing key 1 for 3 seconds only if the
fumes motor has stopped and if 15 minutes have passed from
displaying the same alarm.
fuMes failuRe
Fault related to the flue gas exhaust
motor.
The restoration operations must be carried out by an authorised
technician.
fuMes pRoBe
Fault related to the fumes probe.
The restoration operations must be carried out by an authorised
technician.
fuMes
oveRteMp al.
The flue gas temperature has
exceeded 310°C
Check the pellet flow (see “Pellet feed adjustment”).
Check that the machine is clean, including the fumes route.
Do not rest cloths on the machine.
Other restoration operations must be carried out by an authorised
technician.
Clean CHeCK up 1 - 2
(1 = in BuRning pHase)
(2 = in opeRant pHase)
The combustion chamber or burn pot
bottom are dirty.
The door is not closed correctly.
The ash pan is not closed correctly.
The depression sensor is faulty.
The flue exhaust pipe is blocked.
Incorrect installation
Make sure the holes at the burn pot bottom are completely free.
Check cleanliness of the fumes pipe and the combustion chamber.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Other restoration operations must be carried out by an authorised
technician.
DepR
alaRM
The mechanical depression sensor
has tripped
Contact after-sales centre
no
ignition
The pellet feed-box is empty.
Pellet feed calibration inadequate.
Incorrect installation
Check for the presence of pellets in the feed-box.
Adjust the pellet flow (see “Pellet feed adjustment”).
Check the procedures described in the “Ignition” chapter.
Other restoration operations must be carried out by an authorised
technician.
no ignition BlaCK
out
No power during the ignition phase.
Switch the stove to OFF using key 1 and repeat the procedure
described in the "Ignition" chapter.
Other restoration operations must be carried out by an authorised
technician.
no pellets
In the work phase, the t° of the flue
gases has dropped below factory
parameters
Check for the presence of pellets in the feed-box.
Regulate the pellet flow.
Other restoration operations must be carried out by an authorised
technician.
Cooling stanD-By
Attempt to release the alarm with
stove still in cooling mode.
Every time the stove displays one of the alarms listed above it will
switch-off automatically.
The stove will block any release attempt during this phase,
showing the alarm itself and STAND-BY alternately on the display.
The alarm can be reset by pressing key 1 for 3 seconds only if the
fumes motor has stopped and if 15 minutes have passed from
displaying the same alarm.
DepR sensoR
DaMage
Component disconnected or faulty
Contact after-sales assistance
CoMManD augeR
alaRM
Abnormal functioning
of pellet feeding
Contact after-sales assistance
26