Page 1: ...MADE IN ITALY design production MIETTA EVO SINFONY UK PELLET STOVES USER MANUAL 004280462 Rev 000...

Page 2: ...2 ENGLISH APPLY TECHNICAL DATA LABEL...

Page 3: ...1 4 25 SETTINGS 27 DISPLAY 27 STAND BY 27 OPERATION WITH ADDITIONAL THERMOSTAT OPTIONAL 27 DELTA T 28 FIRST LOAD 28 CLEANING 28 RESET 28 EASY CONTROL 28 ADDITIONAL FUNCTIONS 29 SUPPLEMENTARY THERMOSTA...

Page 4: ...VITER DES D G TS VORSICHT OBLIGATORISCH BEVOR SIE DEN OFEN BEWEGEN BITTE UNBEDINGT DIE BEZEICHNETE KERAMIK KACHELN ENTFERNEN UM SCH DEN ZU VERMEIDEN ATENCI N PERENTORIO ANTES DE MOVER LA ESTUFA SACAR...

Page 5: ...S POUR VITER DES D G TS VORSICHT OBLIGATORISCH BEVOR SIE DEN OFEN BEWEGEN BITTE UNBEDINGT DIE BEZEICHNETE KERAMIK KACHELN ENTFERNEN UM SCH DEN ZU VERMEIDEN ATENCI N PERENTORIO ANTES DE MOVER LA ESTUFA...

Page 6: ...ance has been installed as well as the instructions contained in this manual The use of the appliance must comply with all local regional national and European regulations The Manufacturer cannot be h...

Page 7: ...IF IT IS DISCONNECTED FROMTHE MAINS IT IS ADVISED TO POSITION THE POWER SUPPLY CABLE SO THAT IT DOES NOT COME INTO CONTACT WITH HOT PARTS OFTHE APPLIANCE THE POWER SUPPLY PLUG MUST BE ACCESSIBLE AFTE...

Page 8: ...CLEAN THE MAJOLICAS IT IS RECOMMENDED TO USE A SOFT DRY CLOTH IF A DETERGENT OR LIQUID IS USED THE LATTER COULD PENETRATE INSIDE THE CRACKLES HIGHLIGHTING THEM SINCE THE PRODUCT CAN TURN ON AUTOMATICA...

Page 9: ...th moisture content 12 Seasonal space heating energy efficiency Space heating emissions at nominal heat output Space heating emissions at minimum heat output Nominal heat output Minimum heat output in...

Page 10: ...omestichotwaterproductionandinadjacentandcommunicating rooms 3 where the depression measured in situ between the external and internal environment is greater than 4 Pa N B Watertight appliances can al...

Page 11: ...always be insulated The smoke ducts must have at least one airtight inlet for flue gas sampling All the sections of the flue gas duct must be accessible to inspection Inspection openings must be prov...

Page 12: ...installed This means that it is ideal for passive houses because it does not take air in from within the house COMBUSTION AIR To ensure the stove remains hermetically sealed the connection pipe for th...

Page 13: ...DETAILS A Room air outlet E Radio emergency card I Additional thermostat input B Pellet hopper pressurised closure F ON OFF j Combustion air inlet C Access to combustion chamber G Fuse K Fumes outlet...

Page 14: ...TAILS A Room air outlet E Radio emergency card I Additional thermostat inlet B Pellet hopper pressurised closure F ON OFF j Combustion air inlet C Access to combustion chamber G Fuse K Fumes outlet D...

Page 15: ...isplay to show the following CLOSE HOPPER STOVE DOOR This indication means that you have 60 seconds to close the hatch door and the pellet lid After the 60 seconds during ignition the stove will go in...

Page 16: ...OR QUALITY PELLETS OR ANY OTHER MATERIAL DAMAGES THE FUNCTIONS OF THE GENERATOR AND MAY INVALIDATE THE WARRANTY AND RELIEVE THE MANUFACTURER OF ALL RESPONSIBILITY Keep clean The pellet used must compl...

Page 17: ...r L2 LED off stove off LED on stove in P1 2 3 and operating LED flashing stove in P1 2 3 and off in alarm on stand by P2 Increase power L3 LED off stove off LED on stove in P3 4 5 and operating LED fl...

Page 18: ...n the display In this case repeat the procedure J THE RADIO CONTROL DEVICE IS ALREADY CONFIGURED WITH UNIT 0 IF THERE IS ANOTHER STOVE TO AVOID INTERFERENCES A NEW CONFIGURATION MUST BE PERFORMED MODI...

Page 19: ...adio control device is fitted with an LCD backlit display The display remains lit for 5 seconds After a certain period of time in order to minimise battery consumption the display turns off Sleep mode...

Page 20: ...E TERMINAL TA DISPLAY Display text Temperature detected in room Set ambient temperature Power 1 5 Time Chrono active STAND BY active Battery low Display text Time Indicates contact of the external add...

Page 21: ...roduct at the maximum power and temperature Avoid remaining in the room for a long time Do not touch the surfaces of the product Notes The process is completed after a few heating cooling cycles Do no...

Page 22: ...T AND RESULT IN THE IMMEDIATE NULLIFICATION OF THE WARRANTY PERIOD IN THE EVENT OF WEAR OR DETERIORATION REQUEST THE PART S REPLACEMENT FROM THE AFTER SALES SERVICE REPLACEMENT DOES NOT FALL WITHIN TH...

Page 23: ...m power If the contact is closed request the stove works at the set power If the setting is on HOT set above 37 C the stove always operates at the set power ignoring the external contact and the tempe...

Page 24: ...on the burning pot access the EASY SETUP program and lower the value by one unit to 1 then wait until the next day and if there is no improvement decrease again to a maximum of 3 Instead if it is nec...

Page 25: ...and also the desired power Current day and time settings are essential for the correct operation of the Chrono To set OK CHRONO PRGX ENABLING Allows the chrono and the different stove time slots to b...

Page 26: ...3 1 02 00 23 00 08 00 16 30 t 22 18 2 1 26 ENGLISH Time slot 1 Start 02 00 Stop 23 00 Power 3 set temp 22 C Time slot 2 Start 08 00 Stop 16 30 Power 1 set temp 18 C Stove operation Time slot Power Set...

Page 27: ...n the STAND BY function is not enabled OFF if the stove exceeds the set ambient temperature it will switch to the minimum power level modulating and displaying MODULATION on the screen When the room t...

Page 28: ...ating the combustion chamber cleaning operations CONTROLS PROCEDURE Press key 6 Press 3 until SETTINGS appears and confirm by pressing 6 Keep pressing 3 until CLEANING appears and confirm by pressing...

Page 29: ...TION OPTIONAL The stove can control the room temperature through a supplementary thermostat optional After ignition by pressing key 1 or in chrono mode the stove will work to reach the set value on th...

Page 30: ...hemically aggressive detergents for cleaning The ceramic glass must be cleaned when the glass is completely cold To clean the ceramic glass simply use a dry brush and some damp newspaper dipped in ash...

Page 31: ...combustion chamber and the bottom of the burn pot completely using a suitable vacuum cleaner B Clean the ash conveyor using the special tool to remove any deposits C Clean the chamber probe take care...

Page 32: ...se each time the flue pipe needs to be vacuumed and cleaned If there are horizontal sections the residue must be removed to prevent it from obstructing the flow of fumes SHUT DOWN END OF SEASON At the...

Page 33: ...1 2 SINFONY MIETTA EVO 33 ENGLISH HEAT EXCHANGER AND INSPECTION COMPARTMENT THE IMAGES ARE FOR ILLUSTRATIVE PURPOSES...

Page 34: ...cated C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete emptying and cleaning and check gasket E Check the air intake pipe and check clean the mechan...

Page 35: ...cone in the provided points B Gaskets pellet hopper inspections ash drawer and door replace and apply silicone where indicated C Combustion chamber and heat exchanger full cleaning including ignition...

Page 36: ...re ignition due to an external thermostat COOLING STAND BY A new ignition is attempted when the generator has just been switched off When the generator switches off one must wait for the complete shut...

Page 37: ...The door is not closed correctly The ash drawer is not closed correctly Check that the door closes correctly Check that the burn pot is clear and clean The automatic cleaning of the burn pot is block...

Page 38: ...kindly asked to separate this equipment and or batteries or accumulators included from other types of waste and to arrange for disposal by the municipal waste service It is possible to ask your local...

Page 39: ...39 ENGLISH...

Page 40: ...Y 39 0445 865911 39 0445 865912 info extraflame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manuf...