33
32
EN
EN
a result of inappropriate charging parameters. Protect
the power cord of the charger against damage.
•
WARNING
y
Use the floodlight exclusively with the Li-ion batte-
ry intended for powering cordless power tools of
the SHARE 20 V program. Using the floodlight with
a different battery may lead to a fire or explosion as
a result of inappropriate power supply parameters.
c) Connect the charger to an el. power source.
d) On charger
Extol® Premium 8891893NZ
(model
with a charging current of 2.4 A) and
Extol®
Premium 8891891NZ
(charging current 1.6 A) the
charging process is indicated by a green flashing diode
with a red lit diode, whilst a fully charged battery is
indicated by only a green lit indicator light. On charger
Extol® Premium 8891892NZ
(model with a charging
current of 4 A) the charging process is indicated only
by a red lit LED indicator light and the fully charged
process by only a green lit LED indicator light. The
battery charge level can be seen by the number of lit
LED indicator lights on the battery, which are lit while
the battery is charging. The manufacturer reserves the
right to modify the above-described indication of the
charging and charged process.
•
WARNING
y
Due to its high charging current, charger
Extol®
Premium 8891892NZ
with a charging current of
4 A
must not be used for charging battery
Extol® 8891880
with a capacity of
1.5 Ah
.
APPROXIMATE BATTERY CHARGING TIMES
Battery 4000 mAh (Extol®8891882)
4 A charger Extol® 8891892NZ
1 hours 10 min.
2.4 A charger Extol® 8891893NZ
1.5 hours
1.6 A charger Extol® 8891891NZ
2 hours 45 min.
Battery 2000 mAh (Extol®8891881)
4 A charger Extol® 8891892NZ
40 min.
2.4 A charger Extol® 8891893NZ
55 min.
1.6 A charger Extol® 8891891NZ
1 hours 20 min.
Battery 1500 mAh (Extol®8891880)
4 A charger Extol® 8891892NZ
DO NOT USE
2.4 A charger Extol® 8891893NZ
30 min.
1.6 A charger Extol® 8891891NZ
1 hours
Table 2
e) After charging, first disconnect the charger
from the el. power source
and then, after pressing
and holding down the button lock on the battery,
slide the battery out of the grooves in the charger.
IV. Preparing the LED
floodlight for use
1. Insert the battery into the floodlight so that it clicks
in, and then put on the battery cover.
•
WARNING
y
Without the battery compartment cover
attached, the floodlight cannot be used
in the rain and it is necessary to protect
it against the ingression of water - the
battery and its contacts inside the floodli-
ght are not watertight.
•
WARNING
y
Use the floodlight exclusively with the Li-ion batte-
ry intended for powering cordless power tools of
the SHARE 20 V program. Using the floodlight with
a different battery may lead to a fire or explosion as
a result of inappropriate power supply parameters.
2. Use the button next to the LED indicator lights to set
the required light intensity 1800 lm / 1000 lm / 500 lm.
3. The floodlight can be variably set in the horizontal
direction and secured in position using lateral screws
on the sides of the stand.
II. Technical specifications
Model number (part number)
8891870
1× Li-ion battery 20 V 2000 mAh (8891881)
1× charger 2.4 A (8891893NZ)
8891871
(without battery and charger)
Nominal input voltage
18 V DC
(terminal voltage of battery without load: 20 V DC)
Luminous flux
1800 lm (100 %); 1000 lm (56%); 500 lm (28%)
LED power output
30 W
Light colour temperature
6000 K
Directional light angle
> 120°
Dimensions with the stand (W × H × D)
250 × 300 × 205 mm
Dimensions of the floodlight (W × H × D)
178 × 140 × 90 mm
Weight with battery 2000 mAh
2.0 kg
Weight with battery 4000 mAh
2.3 kg
Illumination time when a 2 Ah or 4 Ah battery is used
1800 lm
: 1 h 15 min. (2Ah)/2.5 hours (4 Ah)
1000 lm
: 2 hours (2Ah)/4.5 hours (4 Ah)
500 lm
: 6 hours (2 Ah)/9 hours (4 Ah)
•
WARNING
y
Carefully read the entire user‘s manual before preparing
LED floodlight for use and before using it, and keep it
with the product so that the user can become acquain-
ted with it. If you lend or sell the product to somebody,
include this user‘s manual with it. Prevent this user‘s
manual from being damaged. The manufacturer takes
no responsibility for damages or injuries arising from
use that is in contradiction to this user‘s manual. Before
using this appliance, first acquaint yourself with all the
control elements and parts as well as how to turn it
off immediately in the event of a dangerous situation
arising. Before using, first check that all parts are firmly
attached and check that no part of the power tool, such
as for example safety protective elements, is damaged
or incorrectly installed, or missing. This also applies
to the charger and its power cord. If the charger or its
power cord (including insulation) is damaged, do not
use it and have it replaced with a flawless original char-
ger from the manufacturer.
III. Charging the battery
y
To check the battery power level, press the button on the
battery and based on the number of lit diodes and the
expected duration of operation of the floodlight, charge
the battery if necessary. If the battery is fully charged,
all the LED diodes are lit. The battery can be charged
from any charge level without reducing its capacity.
•
ATTENTION
y
Charge the battery at an ambient temperature range
of 10°C-40°C.
a) First insert the battery into the grooves of the
supplied charger.
b) Before connecting the charger to the power sour-
ce, check that the voltage in the power socket
corresponds to the range 220-240~50 Hz and that
the charger does not have a damaged power cord
(e.g. insulation) or case or another part.
•
WARNING
y
If the charger is damaged, have it replaced with an
original in perfect working order from the manufactu-
rer. Only the original charger from the manufacturer
may be used for charging the battery, otherwise using
a different charger may cause a fire or explosion as