USER GUIDE 

 

 

 

 

Current / Voltage Calibrator 

 

Model PRC15 

 

 

Summary of Contents for PRC15

Page 1: ...USER GUIDE Current Voltage Calibrator Model PRC15 ...

Page 2: ...ent Double insulation Safety Notes Do not exceed the maximum allowable input range Turn the unit OFF when the device is not in use Remove the batteries if the device is to be stored for longer than 60 days Never dispose of batteries in a fire Batteries may explode or leak Never mix battery types Always install new batteries of the same type Cautions Improper use of this meter can cause damage shoc...

Page 3: ...tton mA or 7 I O MODE button 8 MEM memory STEP button 9 Backlight ZERO button 10 Test lead input jacks Display Layout 1 SOURCE mode icon 2 ZERO function status icon 3 MEASURE mode icon 4 Auto Power OFF active icon 5 Battery status icon 6 Measure mode value 7 Measure mode units icon 8 Datalogger memory location 9 Source mode value 10 Source mode units icon ...

Page 4: ...mA or units or V or mV in the voltage function Voltage is autoranging in the MEASURE mode I O BUTTON Momentarily press the I O button to select either SOURCE output or MEASURE input MODE BUTTON In the MEASURE mode Press and Hold the MODE I O button for 1second to select either the current mA or voltage mV V function Release the button when the desired function appears Backlight BUTTON Press the Ba...

Page 5: ... SOURCE mode 2 Press and HOLD the STEP MEM button STEPSS single cycle and STEPSC continuous cycle will alternately appear in the display Release the button when the desired mode is displayed 3 In single cycle mode the meter will source the current or voltage displayed in MEM01 for 5 seconds The meter will then advance to MEM02 for 5 seconds This will continue through MEM05 and then step down throu...

Page 6: ...00V The current or voltage can be output either manually or stepped from memory as described earlier 1 Turn the meter ON 2 MEASURE will appear in the display 3 Press and Hold the MODE button for 1 second to select mA or or mV 4 Momentarily press the I O button to select SOURCE 5 Press the UNIT button to select mA or mV V 6 Connect the Calibration Cable to the meter 7 Connect the Calibration Cable ...

Page 7: ...e battery cover 2 Remove and replace the batteries observing polarity 3 Replace and secure the battery cover All EU users are legally bound by the Battery Ordinance to return all used batteries to community collection points or wherever batteries accumulators are sold Disposal in household trash or refuse is prohibited Disposal Follow the valid legal stipulations in respect of the disposal of the ...

Page 8: ...ude 7000ft 2000meters maximum Dimensions 159 x 80 x 44 mm 6 3 x 3 2 x 1 7 s e i r e t t a b t u o h t i w z o 3 8 g 4 3 2 t h g i e W Range Specifications Mode Function Range Resolution Accuracy of reading Current 0 to 50mA 0 01mA Percent 25 to 230 0 1 0 to 1999mV 1mV DC Measure Voltage autorange 2 to 20V 0 01V Current 0 to 24mA 0 01mA Percent 25 to 125 0 1 0 to 2000mV 1mV DC Source Voltage 0 to 2...