6
FREQUENCY
Function Sensitivity
(ACrms)
Range
mV 300mV
10Hz
-
125kHz
5V 2V 10Hz
-
125kHz
50V 20V 10Hz
-
20kHz
500V 80V
10Hz
-
1kHz
1000V 300V
10Hz
-
1kHz
Ω
, Cx, diode
300mV 10Hz
-
125kHz
µ
A, mA, A
10% F.S.
10Hz - 125kHz
Accuracy: 0.01% + 2d
Accuracy Notes:
Accuracy is
±
(% reading number of digits), or
as otherwise specified, at 23
°
C
±
5
°
C < 75% R.H. True RMS accuracies
are specified from 5% to 100% of range or as otherwise specified.
Maximum Crest Factor <3:1 at full scale & <6:1 at half scale (with
frequency component within the specified frequency bandwidth for non-
sinusoidal waveforms).
Audible Continuity:
Measurement threshold: Beeper will sound if measurement is below
20
Ω
. Beeper will not sound if measurement is above 200
Ω
. Beeper
may or may not sound if measurement is between 20 and 200
Ω
.
Response time: < 100
µ
s
Digital Display:
5000-count LCD display; 5 per second
nominal refresh rate
Bar Graph Display:
52-segment bargraph; 60 per second nominal
refresh rate
Datalogging Capacity:
43000 points
Datalog Sample Rate:
0.05 (0.2 for
o
C/
o
F &
Ω
, 0.4 for HZ and 1 for
C), 1, 20, 40, 60, 120, 240 & 480 seconds
Low Battery:
Below approx. 7V
Operating Temperature:
32
°
to 113
°
F (0
°
to 45
°
C)
Storage Temperature:
-4
°
to 140
°
F (-20 to 60
o
C
Relative Humidity:
Max 80% up to 87ºF (31ºC) decreasing
linearly to 50% at 113ºF (45ºC) <80% storage
Altitude:
Operating below 2000 meters