MN62
‐
en
‐
GB_V1.1
12/15
7
Operating
Instructions
WARNING
:
Risk
of
electrocution.
High
‐
voltage
circuits,
both
AC
and
DC,
are
very
dangerous
and
should
be
measured
with
great
care.
1.
ALWAYS
turn
the
function
switch
to
the
OFF
position
when
the
meter
is
not
in
use.
2.
If
OL
appears
in
the
display
during
a
measurement,
the
value
exceeds
the
selected
range.
Change
to
a
higher
range.
3.
If
the
meter
does
not
switch
on
when
the
function
dial
is
turned
to
any
position
other
than
OFF,
please
check
the
batteries.
Refer
to
the
Battery
Installation
section
of
this
guide.
AUTO
POWER
OFF
(APO)
The
APO
feature
turns
the
meter
off
after
15
minutes
of
inactivity.
To
disable
APO,
hold
the
SELECT
button
while
turning
the
meter
on.
The
meter
will
emit
5
beeps
indicating
that
APO
has
been
disabled
(the
APO
clock
icon
will
not
be
visible
on
the
display).
Turn
the
meter
off
and
then
on
again
to
re
‐
enable
APO
(the
APO
clock
icon
will
be
visible
on
the
display
when
APO
is
active).
AUTOMATIC
and
MANUAL
Range
The
meter
defaults
to
AUTO
Range
mode
when
it
is
switched
ON.
In
this
mode
the
meter
automatically
selects
the
best
range
for
the
measurements
being
made
and
is
generally
the
best
mode
for
most
measurements.
For
measurement
situations
requiring
that
a
range
be
manually
selected,
perform
the
following:
1.
Press
the
RANGE
button.
The
“AUTO
RANGE”
display
indicator
will
turn
off.
2.
Press
the
RANGE
button
to
step
through
the
available
ranges.
3.
To
exit
the
Manual
Ranging
mode
and
return
to
Auto
ranging,
press
and
hold
the
RANGE
button
for
2
seconds.
MAX/MIN
Memory
1.
Press
the
MAX/MIN
button
to
activate
the
MAX/MIN
recording
mode.
The
display
icon
MAX
will
appear.
The
meter
will
display
and
hold
the
maximum
reading
and
will
update
only
when
a
new
maximum
reading
occurs.
2.
Press
the
MAX/MIN
button
again
and
the
display
icon
MIN
will
appear.
The
meter
will
display
and
hold
the
minimum
reading
and
will
update
only
when
a
new
minimum
reading
occurs.
3.
To
exit
MAX/MIN
mode
press
and
hold
the
MAX/MIN
button
for
2
seconds.
Relative
mode
The
relative
measurement
feature
allows
the
user
to
make
measurements
relative
to
a
stored
reference
value.
A
reference
voltage,
current,
etc.
can
be
stored
where
subsequent
measurements
can
be
made
in
comparison
to
that
stored
reference
value.
The
displayed
value
is
the
difference
between
the
reference
value
and
the
measured
value.
1.
Perform
a
measurement
as
described
in
the
operating
instructions.
2.
Press
the
REL
button
to
store
the
reading;
the
Relative
indicator
will
appear
on
the
display.
3.
The
display
will
now
indicate
the
difference
between
the
stored
and
measured
value.
4.
Press
the
REL
button
to
exit
the
relative
mode.
The
Relative
indicator
will
switch
OFF.
www.
.com
1.800.561.8187