Extech Instruments MM750W User Manual Download Page 18

MM750W-en-GB_v1.1   12/18 

18 

FCC COMPLIANCE 

A  wireless  module must  be  installed  in  the  meter  before the  module  can  communicate 

with iOS®/Android™

 phones and tablets via Bluetooth® using the 

ExView® W

 application. 

 
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:  
1. This device may not cause harmful interference.  
2. This device must accept any interference received, including interference that may cause undesired operation.  
 
IC: 1590A-MM750W 
FCC ID: IWK-MM750W 
  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in 
a  residential  installation.  This  equipment  generates,  uses,  and  can  radiate  radio  frequency  energy  and,  if  not 
installed and used in accordance with the instructions, may cause harmful interference to radio communications. 
However,  there  is  no  guarantee  that  interference  will  not  occur  in  a  particular  installation.  If  this  equipment 
does  cause  harmful  interference  to  radio  or  television  reception,  which  can  be  determined  by  turning  the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following 
measures:  
1. Reorient or relocate the receiving antenna.  
2. Increase the separation between the equipment and receiver.  
3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
4. Consult the dealer or an experienced radio/TV technician for help.  
  

WARNING  

Changes or modifications not expressly approved by the party responsible for compliance could void the user's 
authority to operate the equipment.  

 

Maintenance 

WARNING

:  To avoid electric shock, disconnect the test leads from any source of 

voltage before removing the back cover or the battery or fuse covers. 

 

WARNING: 

To avoid electric shock, do not operate your meter until the battery and 

fuse covers are in place and fastened securely. 

We designed this meter to provide years of dependable service, please follow these 
instructions carefully: 

1.

 

KEEP THE METER DRY

. If it gets wet, allow it to fully dry before use. 

2.

 

USE AND STORE THE METER IN NORMAL TEMPERATURES.

 Temperature extremes 

can shorten the life of the electronic parts and distort or melt plastic parts. 

3.

 

HANDLE THE METER GENTLY AND CAREFULLY.

 Dropping it can damage the 

electronic parts or the case. 

4.

 

KEEP THE METER CLEAN.

 Wipe the case occasionally with a damp cloth. Do not use 

abrasives, chemicals, cleaning solvents, or detergents. 

Summary of Contents for MM750W

Page 1: ...USER MANUAL Wireless Datalogging CAT IV True RMS Multimeter Model MM750W...

Page 2: ...NTS 10 AC VOLTAGE FREQUENCY DUTY CYCLE MEASUREMENTS 10 DC CURRENT MEASUREMENTS 11 AC CURRENT FREQUENCY DUTY CYCLE MEASUREMENTS 12 CLAMP ADAPTOR MEASUREMENTS AC DC 13 RESISTANCE MEASUREMENTS 14 CONTINU...

Page 3: ...W Series application Rated CAT IV 600V CAT III 1000V Safety This symbol adjacent to another symbol terminal or operating device indicates that the operator must refer to an explanation in the Operati...

Page 4: ...e operating the meter Always remove the test leads before replacing the battery or fuses Inspect the condition of the test leads and the meter itself for any damage before operating the meter Use grea...

Page 5: ...nnect the meter leads across a voltage source while the function switch is in the current resistance or diode position doing so can damage the meter 5 ALWAYS discharge filter capacitors in power suppl...

Page 6: ...Control buttons 4 Function switch 5 Positive 10A input terminal 6 COM negative input terminal 7 Positive terminal for all inputs except 10A METER BACK 1 Wireless module compartment 2 Test lead holders...

Page 7: ...or data transmission ON OFF Short press to select one of the functions available for a given rotary switch position Long press while powering up to defeat Auto Power OFF APO Short press for Data Hold...

Page 8: ...t the desired range manually before entering MAX MIN mode If the reading exceeds that range OL will appear Auto Range mode will re activate when you exit MAX MIN mode 1 Short press MAX MIN to activate...

Page 9: ...before automatically powering off after which the meter loudly beeps once as it switches off To wake the meter press the M button no need to turn the rotary switch To disable APO press and hold the M...

Page 10: ...some 240V outlets As a result the reading may show 0 volts when the outlet actually has voltage Make sure the probe tips are touching the metal contacts inside the outlet before assuming that no volta...

Page 11: ...tch to the A position and insert the red test lead banana plug into the A mA jack 3 For current measurements up to 600mA DC set the function switch to the mA position and insert the red test lead bana...

Page 12: ...or current measurements up to 600mA AC set the function switch to the mA position and insert the red test lead banana plug into the A mA jack 4 For current measurements up to 10A AC set the function s...

Page 13: ...lamp adaptor s positive lead to the meter s positive jack 5 The meter displays 1A per each mV input for example with a 3mV input the meter will display 3A 6 Take a current measurement with the externa...

Page 14: ...connect one side of the part under test so the rest of the circuit will not interfere with the resistance reading 5 Read the resistance in the display CONTINUITY CHECK WARNING To avoid electric shock...

Page 15: ...ear 0V and an open device will indicate OL in both polarities CAPACITANCE MEASUREMENTS WARNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors before takin...

Page 16: ...or leave in open air 7 Read the temperature on the display Use the M button to select o C or o F NCV NON CONTACT EF VOLTAGE MEASUREMENTS WARNING Check the NCV function on a known live circuit before t...

Page 17: ...and secure with the two screws before use OBTAINING THE APPLICATION APP For iOS devices download the ExView W application from the Apple App Store For Android devices download the ExView W applicatio...

Page 18: ...nd on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment an...

Page 19: ...te As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dis...

Page 20: ...6 000A 0 001A 1 5 reading 5 digits 10 00A 15 secs 0 01A AC Current 600 0 A 0 1 A 0 15 reading 5 digits 6000 A 1 A 60 00mA 0 01mA 600 0mA 0 1mA 6 000A 0 001A 1 5 reading 5 digits 10 00A 15 secs 0 01A...

Page 21: ...ions consist of two elements of reading Accuracy of the measurement circuit digits Accuracy of the analog to digital converter AC Response True RMS responding Input Impedance 10M ohm for Voltage AC DC...

Page 22: ...n 2012 04 ELECTRICAL EQUIPMENT FOR MEASUREMENT CONTROL AND LABORATORY USE Part 1 General Requirements IEC 61010 1 2010 3rd Edition IEC 61010 2 033 Edition 1 0 2012 04 Approvals CE Contact Customer Sup...