Extech Instruments EX410A User Manual Download Page 7

EX410A-en-GB_V6.0   6/16 

7

AC VOLTAGE MEASUREMENTS 

WARNING: 

 Risk of Electrocution. The probe tips may not be long enough to contact the live parts 

inside some 240V outlets for appliances because the contacts are recessed deep in the outlets. As 
a result, the reading may show 0 volts when the outlet actually has voltage on it. Make sure the 
probe tips are touching the metal contacts inside the outlet before assuming that no voltage is 
present. 

CAUTION: 

 Do not measure AC voltages if a motor on the circuit is being switched ON or OFF. 

Large voltage surges may occur that can damage the meter. 

1.  Set the function switch to the highest V AC (      ) position. 
2.  Insert the black test lead banana plug into the negative 

COM

 jack. 

Insert red test lead banana plug into the positive 

V

 jack. 

3.  Touch the black test probe tip to the neutral side of the circuit.  

Touch the red test probe tip to the  hot  side of the circuit. 

4.  Read the voltage in the display. Reset the function switch to successively 

lower V AC positions to obtain a higher resolution reading.

DC CURRENT MEASUREMENTS 

CAUTION: 

 Do not make current measurements on the 10A scale for longer than 30 seconds. 

Exceeding 30 seconds may cause damage to the meter and/or the test leads. 

1.  Insert the black test lead banana plug into the negative 

COM

 jack. 

2.  For current measurements up to 200µA DC, set the function switch to the 

200µA DC (

) position and insert the red test lead banana plug into the 

uA/mA

 jack. 

3.  For current measurements up to 200mA DC, set the function switch to the 

200mA DC position and insert the red test lead banana plug into the 

uA/(mA

 jack. 

4.  For current measurements up to 10A DC, set the function switch to the 

10A DC range and insert the red test lead banana plug into the 

10A

 jack. 

5.  Remove power from the circuit under test, then open up the circuit at the 

point where you wish to measure current. 

6.  Touch the black test probe tip to the negative side of the circuit.  

Touch the red test probe tip to the positive side of the circuit. 

7.  Apply power to the circuit. 
8.  Read the current in the display. 

www.

.com

[email protected]

1.800.561.8187

www.calcert.com

[email protected]

1.800.544.2843

0

5

10

15

20

25

30

Summary of Contents for EX410A

Page 1: ...USER MANUAL Digital Multimeter MODEL EX410A www com information itm com 1 800 561 8187 www calcert com sales calcert com 1 800 544 2843 0 5 10 15 20 25 30...

Page 2: ...or terminal indicates the user must refer to the manual for further information This symbol adjacent to a terminal indicates that under normal use hazardous voltages may be present Double insulation T...

Page 3: ...ical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts Other means should be used to ensure that the terminals are not live If the eq...

Page 4: ...0Vrms on 200mV range mA DC 200mA 600V fast acting fuse A DC 10A 600V fast acting fuse 30 seconds max every 15 minutes Ohms Continuity 250Vrms for 15sec max 2 USE EXTREME CAUTION when working with high...

Page 5: ...jack 8 Positive input jack 9 Battery check button 10 Hold button freezes displayed reading 11 LCD backlight button Note Tilt stand test lead holders and battery compartment are on rear of unit Symbols...

Page 6: ...n connected to a circuit DC VOLTAGE MEASUREMENTS CAUTION Do not measure DC voltages if a motor on the circuit is being switched ON or OFF Large voltage surges may occur that can damage the meter 1 Set...

Page 7: ...r V AC positions to obtain a higher resolution reading DC CURRENT MEASUREMENTS CAUTION Do not make current measurements on the 10A scale for longer than 30 seconds Exceeding 30 seconds may cause damag...

Page 8: ...red test probe tip to the hot side of the circuit 6 Apply power to the circuit 7 Read the current in the display RESISTANCE MEASUREMENTS WARNING To avoid electric shock disconnect power to the unit u...

Page 9: ...to the diode under test Forward bias will typically indicate 400 to 1000 Reverse bias will indicate 1 Shorted devices will indicate near 0 and the continuity beeper will sound An open device will indi...

Page 10: ...r the function selected Specifications Function Range Resolution Accuracy DC Voltage V DC 200mV 0 1mV 0 3 reading 2 digits 2V 0 001V 0 5 reading 2 digits 200V 0 1V 600V 1V 0 8 reading 2 digits AC Volt...

Page 11: ...Battery Indication is displayed if battery voltage drops below operating voltage Battery One 9 volt NEDA 1604 battery Fuses mA A ranges 0 2A 600V fast blow A range 10A 600V ceramic fast blow Operating...

Page 12: ...e removed to prevent damage to the unit Battery Replacement 1 Remove the Phillips head screw that secures the rear battery door 2 Open the battery compartment 3 Replace the 9V battery 4 Secure the bat...

Page 13: ...nter circuit board straight up from the connectors to gain access to the fuse holders 6 Gently remove the old fuse and install the new fuse into the holder 7 Always use a fuse of the proper size and v...

Reviews: