OVERVOLTAGE CATEGORY III 

This meter meets the IEC 61010-1 (2010) 3

rd

 edition standard for OVERVOLTAGE CATEGORY III. 

Cat III meters are protected against overvoltage transients in fixed installation at the distribution 
level. Examples include switches in the fixed installation and some equipment for industrial use with 
permanent connection to the fixed installation. 

SAFETY INSTRUCTIONS 

This meter has been designed for safe use, but must be operated with caution. The rules listed 
below must be carefully followed for safe operation. 

1.

NEVER

 apply voltage or current to the meter that exceeds the specified maximum: 

Input Protection Limits 

Function 

Maximum Input 

V DC or V AC 

600V DC/AC, 200Vrms on 200mV range 

mA DC 

200mA 600V fast acting fuse 

A DC 

10A 600V fast acting fuse (30 seconds max every 15 minutes) 

Ohms, Continuity 

250Vrms for 15sec max 

2.

USE EXTREME CAUTION

 when working with high voltages. 

3.

DO NOT

 measure voltage if the voltage on the "COM" input jack exceeds 600V above earth 

ground. 

4.

NEVER

 connect the meter leads across a voltage source while the function switch is in the 

current, resistance, or diode mode. Doing so can damage the meter. 

5.

ALWAYS

 discharge filter capacitors in power supplies and disconnect the power when making 

resistance or diode tests. 

6.

ALWAYS

 turn off the power and disconnect the test leads before opening the covers to replace 

the fuse or battery. 

7.

NEVER

 operate the meter unless the back cover and the battery cover is in place and fastened 

securely. 

www.

.com

[email protected]

1.800.561.8187

www.calcert.com

[email protected]

1.800.544.2843

0

5

10

15

20

25

30

Summary of Contents for EX410A

Page 1: ...USER MANUAL Digital Multimeter MODEL EX410A www com information itm com 1 800 561 8187 www calcert com sales calcert com 1 800 544 2843 0 5 10 15 20 25 30...

Page 2: ...or terminal indicates the user must refer to the manual for further information This symbol adjacent to a terminal indicates that under normal use hazardous voltages may be present Double insulation T...

Page 3: ...ical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts Other means should be used to ensure that the terminals are not live If the eq...

Page 4: ...0Vrms on 200mV range mA DC 200mA 600V fast acting fuse A DC 10A 600V fast acting fuse 30 seconds max every 15 minutes Ohms Continuity 250Vrms for 15sec max 2 USE EXTREME CAUTION when working with high...

Page 5: ...jack 8 Positive input jack 9 Battery check button 10 Hold button freezes displayed reading 11 LCD backlight button Note Tilt stand test lead holders and battery compartment are on rear of unit Symbols...

Page 6: ...n connected to a circuit DC VOLTAGE MEASUREMENTS CAUTION Do not measure DC voltages if a motor on the circuit is being switched ON or OFF Large voltage surges may occur that can damage the meter 1 Set...

Page 7: ...r V AC positions to obtain a higher resolution reading DC CURRENT MEASUREMENTS CAUTION Do not make current measurements on the 10A scale for longer than 30 seconds Exceeding 30 seconds may cause damag...

Page 8: ...red test probe tip to the hot side of the circuit 6 Apply power to the circuit 7 Read the current in the display RESISTANCE MEASUREMENTS WARNING To avoid electric shock disconnect power to the unit u...

Page 9: ...to the diode under test Forward bias will typically indicate 400 to 1000 Reverse bias will indicate 1 Shorted devices will indicate near 0 and the continuity beeper will sound An open device will indi...

Page 10: ...r the function selected Specifications Function Range Resolution Accuracy DC Voltage V DC 200mV 0 1mV 0 3 reading 2 digits 2V 0 001V 0 5 reading 2 digits 200V 0 1V 600V 1V 0 8 reading 2 digits AC Volt...

Page 11: ...Battery Indication is displayed if battery voltage drops below operating voltage Battery One 9 volt NEDA 1604 battery Fuses mA A ranges 0 2A 600V fast blow A range 10A 600V ceramic fast blow Operating...

Page 12: ...e removed to prevent damage to the unit Battery Replacement 1 Remove the Phillips head screw that secures the rear battery door 2 Open the battery compartment 3 Replace the 9V battery 4 Secure the bat...

Page 13: ...nter circuit board straight up from the connectors to gain access to the fuse holders 6 Gently remove the old fuse and install the new fuse into the holder 7 Always use a fuse of the proper size and v...

Reviews: