CAUTIONS 

  Improper use of this meter can cause damage, shock, injury or death. Read and understand 

this user manual before operating the meter. 

  Always remove the test leads before replacing the battery or fuses. 

  Inspect the condition of the test leads and the meter itself for any damage before operating the 

meter. Repair or replace any damage before use. 

  Use great care when making measurements if the voltages are greater than 25VAC rms or 

35VDC. These voltages are considered a shock hazard. 

  Warning! This is a class A equipment. This equipment can cause interference to devices in the 

home; in this case the operator can be required to carry out adequate measures to prevent 
interference. 

  Always discharge capacitors and remove power from the device under test before performing 

Diode, Resistance or Continuity tests. 

  Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty 

of connection to the recessed electrical contacts. Other means should be used to ensure that 
the terminals are not "live". 

  If the equipment is used in a manner not specified by the manufacturer, the protection provided 

by the equipment may be impaired. 

  This device is not a toy and must not reach children s hands. It contains hazardous objects as 

well as small parts that children could swallow. In case a child swallows any of the parts, 
please contact a physician immediately. 

  Do not leave batteries and packing material unattended; they can be dangerous for children. 

  In case the device is going to be unused for an extended period of time, remove the batteries 

to prevent them from draining. 

  Expired or damaged batteries can cause cauterization on contact with skin. Always use 

suitable hand protection. 

  See that the batteries are not short-circuited. Do not throw batteries into fire. 

www.

.com

[email protected]

1.800.561.8187

www.calcert.com

[email protected]

1.800.544.2843

0

5

10

15

20

25

30

Summary of Contents for EX410A

Page 1: ...USER MANUAL Digital Multimeter MODEL EX410A www com information itm com 1 800 561 8187 www calcert com sales calcert com 1 800 544 2843 0 5 10 15 20 25 30...

Page 2: ...or terminal indicates the user must refer to the manual for further information This symbol adjacent to a terminal indicates that under normal use hazardous voltages may be present Double insulation T...

Page 3: ...ical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts Other means should be used to ensure that the terminals are not live If the eq...

Page 4: ...0Vrms on 200mV range mA DC 200mA 600V fast acting fuse A DC 10A 600V fast acting fuse 30 seconds max every 15 minutes Ohms Continuity 250Vrms for 15sec max 2 USE EXTREME CAUTION when working with high...

Page 5: ...jack 8 Positive input jack 9 Battery check button 10 Hold button freezes displayed reading 11 LCD backlight button Note Tilt stand test lead holders and battery compartment are on rear of unit Symbols...

Page 6: ...n connected to a circuit DC VOLTAGE MEASUREMENTS CAUTION Do not measure DC voltages if a motor on the circuit is being switched ON or OFF Large voltage surges may occur that can damage the meter 1 Set...

Page 7: ...r V AC positions to obtain a higher resolution reading DC CURRENT MEASUREMENTS CAUTION Do not make current measurements on the 10A scale for longer than 30 seconds Exceeding 30 seconds may cause damag...

Page 8: ...red test probe tip to the hot side of the circuit 6 Apply power to the circuit 7 Read the current in the display RESISTANCE MEASUREMENTS WARNING To avoid electric shock disconnect power to the unit u...

Page 9: ...to the diode under test Forward bias will typically indicate 400 to 1000 Reverse bias will indicate 1 Shorted devices will indicate near 0 and the continuity beeper will sound An open device will indi...

Page 10: ...r the function selected Specifications Function Range Resolution Accuracy DC Voltage V DC 200mV 0 1mV 0 3 reading 2 digits 2V 0 001V 0 5 reading 2 digits 200V 0 1V 600V 1V 0 8 reading 2 digits AC Volt...

Page 11: ...Battery Indication is displayed if battery voltage drops below operating voltage Battery One 9 volt NEDA 1604 battery Fuses mA A ranges 0 2A 600V fast blow A range 10A 600V ceramic fast blow Operating...

Page 12: ...e removed to prevent damage to the unit Battery Replacement 1 Remove the Phillips head screw that secures the rear battery door 2 Open the battery compartment 3 Replace the 9V battery 4 Secure the bat...

Page 13: ...nter circuit board straight up from the connectors to gain access to the fuse holders 6 Gently remove the old fuse and install the new fuse into the holder 7 Always use a fuse of the proper size and v...

Reviews: