Capacitance

 

Range

 

Resolution

 

Accuracy

 

 

6.000nF

 

1pF

 

In

 

REL

 

mode:

 

 

±

 

(4%+10

 

digits)

 

60.00n

 

F

 

to

 

600.0

μ

F

 

10pF

 

to

 

0.1

μ

F

 

±

 

(4%+5

 

digits)

 

6.000mF

 

to

 

60.00mF

 

1

μ

F

 

to

 

10

μ

F

 

±

 

10%

 

Overload

 

protection:

 

600V

PTC

 

To

 

optimize

 

accuracy,

 

if

 

the

 

measured

 

capacitance

 

is

 ≤ 

1

μ

F

 

use

 

the

 

REL

 

measurement

 

mode

 

Frequency

 

9.999Hz

 

to 

9.999MHz

 

0.001Hz

 

to 

0.001MHz

 

±

 

(0.1%+5)

 

Duty

 

Cycle

 

0.1%

99.9%

 

0.1%

 

Unspecified

  

Overload

 

protection:

 

600V

PTC

Input

 

amplitude

 

(a):

 

(DC

 

level

 

is

 

zero)

  

100kHz:

 

100mVrms

a

20Vrms

 

100kHz

1MHz:

 

200mVrms

a

20Vrms

 

1MHz:

 

500mVrms

a

20Vrms

 

5MHz

10MHz:

 

900mVrms

≤ 

a

 ≤

20Vrms

 

Duty

 

cycle%:

  

Applies

 

to

 

frequency

 

measurements

 

only

 

(

100kHz)

 

Frequency

 

for

 

Voltage

 

or

 

Current

 

functions:

 

Frequency

 

<1kHz

 

AC

 

voltage:

 

input

 

amplitude

 

of

 

mV

 

range

100mV,

 

input

 

amplitude

 

of

 

V

 

range

≥ 

the

 

range

 

×6%

 

AC

 

current:

 

input

 

amplitude

 

(a):

 

4000/6000

μ

A,

 

400/600mA,

 

10A

 

range:

 

a

 ≥ 

the

 

range

 

×6%,

  

400/600

μ

A,

 

40/60mA,

 

4/6A

 

range:

 

a

 ≥ 

the

 

range

 

×60%

 

 

Function

 

Resolution

 

Remarks

 

Continuity

 

0.1

Ω 

Continuity

 

threshold

 

is

 

10

Ω 

~

 

100

.

 

For

 

measurements

 

<

 

10

Ω 

the

 

buzzer

 

will

 

sound.

 

For

 

measurements

 

>400

Ω 

(>600

Ω 

EX355)

 

the

 

OL

 

symbol

 

will

 

display.

  

Diode

 

1mV

 

Open

circuit

 

voltage

 

is

 

approx.:

 

3.2V.

 

Typical

 

voltage

 

of

 

a

 

silicon

 

PN

 

junction

 

is

 

in

 

the

 

range

 

of:

 

0.5

 

to

 

0.8V

 

 

Temperature

 

EX355

 

Range

 

Resolution

 

‘Accuracy

 

°

C

 

40

 

to

 

0

°

C

 

1

°

C

 

±3

 

°

C

 

>0

 

to

 

100

°

C

 

±

 

(1.0%+3)

 

>100

 

to

 

1000

°

C

 

±

 

(2.0%+3)

 

°F

 

40

 

to

 

32°F

 

1°F

 

±5°F

 

>32

 

to

 

212°F

 

±

1.5%+5)

 

>212

 

to

 

1832°F

 

±

2.5%+5)

 

Type

K

 

thermocouple

 

probe

 

required.

 

The

 

maximum

 

temperature

 

range

 

for

 

the

 

supplied

 

probe

 

is

 

230

o

C/446

o

F.

 

Summary of Contents for EX350

Page 1: ...USER GUIDE True RMS Digital Multimeters EX350 Series EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature...

Page 2: ...s 10 10A AC DC Current Measurements 12 mA A AC DC Current Measurements 13 Non Contact Voltage Detector 14 Resistance Measurements 15 Continuity Measurements 16 Capacitance Measurements 16 Lo Z AC Volt...

Page 3: ...liable service Please visit our website www extech com to check for the latest version of this User Guide Product Updates Product Registration and Customer Support Features 6000 count EX355 or 4000 co...

Page 4: ...r Guide Use caution working with voltages above 30 VAC RMS 42 VAC peak or 60 VDC These voltages pose a shock hazard To avoid misleading readings that could lead to electric shock and injury replace th...

Page 5: ...s in which measures are taken to limit the transient over voltages to an appropriate low level Note Examples include protected electronic circuits OVERVOLTAGE CATEGORY II Equipment of OVERVOLTAGE CATE...

Page 6: ...on 4 Hz button 5 Mode and LPF Button 6 Rotary function select switch 7 10A input terminal 8 uA and mA input terminal 9 Common input terminal 10 Positive input terminal Voltage Resistance Capacitance T...

Page 7: ...o F Temperature units F Farads Capacitance measurement units Hz Hertz Frequency measurements unit Duty Cycle AC only Ohms Resistance measurement unit LPF Variable frequency voltage mode Battery status...

Page 8: ...AC DC TEMP EX355 C F Press and Hold LPF in the ACV function to select variable frequency tests Press R Range to switch from Auto to Manual Range Hold to return to Auto Range Press activates Relative m...

Page 9: ...r OFF after 15 minutes of inactivity To defeat this feature follow the steps below 1 With the meter OFF press and hold the M MODE button and while continuing to hold turn the rotary function switch to...

Page 10: ...r DC EX355 only 4 The meter defaults to the Auto Range mode Auto displayed on LCD Press the R button to access the manual range mode Press the R button to step through the ranges Press and hold the R...

Page 11: ...test Be sure to observe the correct polarity red lead to positive black lead to negative 6 The meter defaults to the Auto Range mode Auto displayed on LCD Press the R button to access the manual rang...

Page 12: ...s and Hold the R button to return to the Auto Range mode 5 Current measurements must be taken in series with the circuit under test See accompanying diagram 6 Touch the black test lead to the negative...

Page 13: ...ss the R button to manually range the meter Press the R button to step through the ranges Press and Hold the R button to return to the Auto Range mode 4 Press the M button to select AC or DC 5 Current...

Page 14: ...e meter does not emit a tone or flash the LED in this mode there is still the possibility that voltage is present Please use caution 1 Turn the function switch to the NCV position to access the Non Co...

Page 15: ...icon showing 4 The meter defaults to the Auto Range mode Auto displayed on LCD Press the R button to access the manual range mode Press the R button to step through the ranges Press and Hold the R bu...

Page 16: ...e Measurements WARNING To avoid electric shock remove power to the circuit under test and discharge the capacitor under test before measuring Do not test on circuits or devices where 60VDC or 30VAC is...

Page 17: ...proper decimal point and measurement type units symbols Variable Frequency Voltage Measurements When the function switch is turned to the LPF position the meter can measure voltage on signals with va...

Page 18: ...e LCD when in Diode test mode 3 Touch the test probe tips to the diode or semiconductor junction under test Note the meter reading 4 Reverse the test lead polarity by reversing the red and black leads...

Page 19: ...rving correct polarity 2 Turn the function switch to the Temp position Use the M button to select the desired unit of measure 3 Touch the temperature probe tip to the device under test or leave the te...

Page 20: ...active Subsequent readings will now be compared to the stored reference Displayed Reading Measurement minus Reference Press the REL button again to exit the Relative mode the Relative symbol will swit...

Page 21: ...y and store separately Fig 5 1 BATTERY AND FUSE REPLACEMENT Fuse Replacement The 600mA fuse can be replaced from the battery compartment 4 To replace the 10A fuse remove the four 4 screws that secure...

Page 22: ...0 2 5 Add 7 0 for C F 2 5 3 0 Function Range Resolution Accuracy DC Voltage EX350 EX355 40 00mV 60 00mV 10 V 0 7 5 digits 400 0mV 600 0mV 0 1mV 0 5 2 digits 4 000V 6 000V 1mV 0 5 3 digits 40 00V 60 00...

Page 23: ...y A EX350 EX355 400 0 A 600 0 A 0 1 A 1 0 3 digits 4000 A 6000 A 1 A mA 40 00mA 60 00mA 10 A 400 0mA 600 0mA 0 1mA A 4 000A 6 000A 1mA 1 2 3 digits 10 00A 10 00A 10mA ACA Frequency Response 45 400Hz F...

Page 24: ...quency for Voltage or Current functions Frequency 1kHz AC voltage input amplitude of mV range 100mV input amplitude of V range the range 6 AC current input amplitude a 4000 6000 A 400 600mA 10A range...

Page 25: ...C 86 to 104 F 50 RH maximum Storage Temperature and Humidity 10 to 50 C 14 to 122 F 80 RH maximum with battery removed Operating Altitude 2000m 6562 Battery power 2 AA batteries battery life 130 hours...

Reviews: