Extech Instruments 381676A User Manual Download Page 10

381676A-en-GB_V1.1   08/15 

10

LOGIC

 

TEST

 

WARNING

:

 

To

 

prevent

 

electric

 

shock

 

and

 

damage

 

to

 

the

 

meter

 

or

 

personal

 

injury,

 

do

 

not

 

measure

 

voltages

 

that

 

may

 

exceed

 

100V

 

AC

 

rms.

 

NOTE:

 

If

 

the

 

test

 

leads

 

are

 

disconnected

 

or

 

if

 

the

 

voltage

 

measured

 

is

 

<

 

1.5V

 

the

 

LED

 

will

 

be

 

green.

 

 

1.

 

Use

 

the

 

probe

 

cover

 

if

 

making

 

measurements

 

on

 

category

 

III

 

or

 

above

 

installations

  

2.

 

Set

 

the

 

function

 

switch

 

to

 

the

 

LOGIC

 

position.

 

3.

 

Insert

 

the

 

black

 

test

 

lead

 

banana

 

plug

 

into

 

the

 

negative

 

(common)

 

jack

 

at

 

the

 

bottom

 

of

 

the

 

meter.

 

4.

 

Connect

 

the

 

black

 

test

 

lead

 

to

 

the

 

circuit’s

 

ground

 

(

)

 

terminal.

 

5.

 

Hold

 

down

 

the

 

Mode

 

(M)

 

button

 

and

 

touch

 

the

 

test

 

probe

 

to

 

the

 

circuit

 

for

 

measurement.

 

The

 

LEDs

 

near

 

the

 

tip

 

of

 

the

 

meter

 

will

 

indicate

 

the

 

current

 

logic

 

level.

 

6.

 

If

 

the

 

measurement

 

is

 

0~1.5V,

 

the

 

Green

 

LED

 

will

 

light

 

and

 

the

 

display

 

will

 

show

 

a

 

down

 

arrow,

 

indicating

 

that

 

the

 

logic

 

test

 

result

 

is

 

a

 

LOW

 

(‘0’)

 

condition.

 

7.

 

If

 

the

 

measurement

 

is

 

1.5~3.5V,

 

the

 

Green

 

and

 

Red

 

LEDs

 

will

 

be

 

OFF.

 

8.

 

If

 

the

 

measurement

 

is

 

3.5~5V,

 

the

 

Red

 

LED

 

will

 

light

 

and

 

the

 

display

 

will

 

show

 

an

 

up

 

arrow,

 

indicating

 

that

 

the

 

logic

 

test

 

result

 

is

 

a

 

HIGH

 

(‘1’)

 

condition.

 

See

 

diagram.

 

 

  0V                       1.5V                                           3.5V                       5V

Green LED ON

Green & Red LED OFF

Red LED ON

LOW  ‘0’

HIGH ‘1’

 

Maintenance

 

WARNING:

  

To

 

avoid

 

electrical

 

shock,

 

disconnect

 

the

 

test

 

leads

 

from

 

any

 

source

 

of

 

voltage

 

before

 

removing

 

the

 

back

 

cover

 

or

 

the

 

battery

 

cover.

 

 

WARNING:

 

To

 

avoid

 

electrical

 

shock,

 

do

 

not

 

operate

 

the

 

meter

 

until

 

the

 

battery

 

cover

 

is

 

in

 

place

 

and

 

fastened

 

securely.

 

This

 

meter

 

was

 

designed

 

to

 

provide

 

years

 

of

 

dependable

 

service.

 

However,

 

if

 

the

 

following

 

guidelines

 

are

 

not

 

followed,

 

the

 

dependability

 

of

 

the

 

meter

 

can

 

be

 

compromised:

 

1.

 

KEEP

 

THE

 

METER

 

DRY

.

 

If

 

it

 

gets

 

wet,

 

wipe

 

it

 

off

 

and

 

allow

 

it

 

to

 

dry

 

before

 

use.

 

2.

 

USE

 

AND

 

STORE

 

THE

 

METER

 

IN

 

NORMAL

 

TEMPERATURES.

 

Environmental

 

extremes

 

can

 

shorten

 

the

 

life

 

of

 

the

 

electronic

 

parts

 

and

 

distort

 

or

 

melt

 

plastic

 

parts.

 

3.

 

HANDLE

 

THE

 

METER

 

GENTLY

 

AND

 

CAREFULLY.

 

4.

 

KEEP

 

THE

 

METER

 

CLEAN.

 

Wipe

 

the

 

case

 

occasionally

 

with

 

a

 

damp

 

cloth.

 

Do

 

not

 

use

 

chemicals,

 

cleaning

 

solvents,

 

abrasives,

 

or

 

detergents.

 

5.

 

USE

 

ONLY

 

FRESH

 

BATTERIES

 

OF

 

THE

 

RECOMMENDED

 

SIZE/TYPE.

 

6.

 

IF

 

THE

 

METER

 

IS

 

TO

 

BE

 

STORED

 

FOR

 

A

 

LONG

 

PERIOD

 

REMOVE

 

THE

 

BATTERIES

  

7.

 

Repairs

 

should

 

only

 

be

 

implemented

 

by

 

trained

 

personnel.

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for 381676A

Page 1: ...USER GUIDE Pen Multimeter with Voltage Detector Model 381676A www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 2: ...tact and free from lead wire exposure or other damage Use only the supplied test leads Safety during use Be sure to set the appropriate function and range before use Never exceed the limits indicated in the specification table of this manual Never touch probes test leads or alligator clip when connected to live circuit Do not measure voltage on terminals that exceed 600V above earth ground Always ...

Page 3: ... test probe 2 Removable probe cover 3 NCV alert LED indicator 4 Logic High Low LED Indicators 5 Finger guard 6 Rotary function switch 7 Range R button 8 Data Hold H button 9 Maximum Hold MAX button 10 Mode M button 11 NCV non contact volt detector button 12 LCD display 13 Jack for Common negative test lead 14 Common negative test lead Note The battery compartment is located on the rear of the inst...

Page 4: ...ain show real time readings MAXIMUM HOLD MAX Button To display only the highest reading press the MAX button The M H display icon will be visible on the display while in the Max Hold mode Now the display will only change when a higher reading than the displayed reading is encountered To return to normal operation press the MAX button again the M H display icon will switch off MODE M BUTTON The Mod...

Page 5: ...0mV range 250V DC or AC rms 2 600V range 600V DC or AC rms Current DC or AC Fuse protection FF400mA 600V Logic Resistance Continuity and Diode 250V DC or AC rms Automatic Power OFF APO The meter is equipped with an automatic power off feature to preserve battery energy After 14 minutes of inactivity the meter will emit 5 short beeps After another minute the meter will emit one long beep before fin...

Page 6: ...the meter as an AC Voltage Detector if the batteries are weak or bad Notes Voltage may still exist even with no indication given by the meter Do not solely rely on NCV detection to determine the presence of voltage Socket design insulation thickness and other factors may affect readings The NCV indicator LED may flash while measuring AC DC voltage due to the presence of induced voltage External en...

Page 7: ...ading will be displayed OL indicates an over range condition in manual mode A higher range should then be selected In manual mode select the highest range first if the value to be measured is unknown then lower the range as needed The AC millivolt range is only available in the manual range mode 1 Use the probe cover if making measurements on category III or above installations 2 Set the function ...

Page 8: ...lects the optimum range or the user may manually select a range by pressing the Range R button Press and hold the Range R button to return to the AUTO Range mode DIODE TEST NOTES The display shows the approximate forward voltage drop If the connections are reversed or the leads are not connected the display will show OL 1 Use the probe cover if making measurements on category III or above installa...

Page 9: ... test from the circuit so the rest of the circuit will not interfere with the resistance reading 6 Read the resistance on the display The meter automatically selects the optimum range or the user may manually select a range by pressing the Range R button Press and hold the Range R button to return to the AUTO Range mode CONTINUITY CHECK WARNING Risk of electric shock Ensure that all power to the c...

Page 10: ...ting that the logic test result is a HIGH 1 condition See diagram 0V 1 5V 3 5V 5V Green LED ON Green Red LED OFF Red LED ON LOW 0 HIGH 1 Maintenance WARNING To avoid electrical shock disconnect the test leads from any source of voltage before removing the back cover or the battery cover WARNING To avoid electrical shock do not operate the meter until the battery cover is in place and fastened secu...

Page 11: ... stipulations in respect of the disposal of the device at the end of its lifecycle Other Battery Safety Reminders Never dispose of batteries in a fire Batteries may explode or leak Never mix battery types Always install new batteries of the same type Test Lead or Alligator Clip Replacements WARNING Replacement leads must be of the same rating or higher as the leads supplied with the meter 600V 10A...

Page 12: ...sponse Average Resistance 200 0 1 1 0 of reading 3 digits 2k 0 001k 1 0 of reading 1 digit 20k 0 01k 200k 0 1k 2M 0 001M 20M 0 01M 1 0 of reading 5 digits Open Circuit Voltage approx 250mV Overload protection 250V DC or AC rms Continuity If measured resistance is 50 beeper will sound Open Circuit Voltage approx 500mV Overload protection 250V DC or AC rms Diode 0 001V Displays approx forward biased...

Page 13: ...emperature 10 o C to 50 o C 14 o F to 122 o F Operating Humidity 80 max non condensing Storage Humidity 70 maximum with battery removed Operating Altitude 2000m 6560 operating Low Battery Indication is displayed to alert battery replacement Batteries Two 2 1 5V AAA batteries Weight Size 129g 4 5oz 208 x 38 x 29mm 8 2 x 1 5 x 1 1 Safety For indoor use and in accordance with the requirements for dou...