Extech Instruments 380340 User Manual Download Page 3

V5.0   5/06 

Compatible Meters 

 

Model No. 

Meter Type 

Display 

In/Out Port 

COM Cable 

407026 Light 

Meter 

Single 

Direct 

UPCB-01 

407112 Vane 

Anemometer 

Dual 

Direct 

UPCB-01 

407113 Vane 

Anemometer 

Dual 

Direct 

UPCB-01 

407114 CFM 

Thermo-Anemometer 

Dual 

Direct 

UPCB-01 

407117 

Mini Vane Thermo-Anemometer Dual  Direct 

UPCB-01 

407119 

Hot Wire CFM Anemometer 

Dual 

Direct 

UPCB-01 

407119A 

Hot Wire CFM Anemometer 

Dual 

Isolated UPCB-02 

407123 

Hot Wire Anemometer 

Dual 

Direct 

UPCB-01 

407227 

pH / mV / Temperature 

Dual 

Direct 

UPCB-01 

407303 Conductivity 

Meter 

Dual 

Direct 

UPCB-01 

407401 Dual 

Thermometer 

Dual 

Direct 

UPCB-01 

407412 

Thermo-Anemometer / Humidity 

Dual 

Direct 

UPCB-01 

407428 IR 

Thermometer 

Single 

Direct 

UPCB-01 

407445 

RH / Temperature Meter 

Dual 

Direct 

UPCB-01 

407495 Pressure 

meter 

Single 

Direct 

UPCB-01 

407510 

Dissolved Oxygen (DO) Meter 

Dual 

Direct 

UPCB-01 

407768 

Sound Level Meter 

Single 

Isolated

 

UPCB-02

 

407777 Moisture 

Meter 

Single 

Direct 

UPCB-01 

407820 Torque 

Meter 

Single 

Direct 

UPCB-01 

407850 Vibration 

Meter 

Single 

Direct 

UPCB-01 

407907 RTD 

Thermometer 

Single 

Direct 

UPCB-01 

407910 

Differential Pressure Manometer 

Single 

Direct 

UPCB-01 

42525A IR 

Thermometer 

Single 

Isolated UPCB-02 

475055 Force 

Gauge 

Single 

Direct 

UPCB-01 

 

Summary of Contents for 380340

Page 1: ...ries Meters The sample rate at which data is recorded is user selectable Readings stored in the Datalogger can later be transferred to a PC using the supplied software and communication cables This device is shipped fully tested and with proper use will provide years of reliable service 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentD...

Page 2: ... 5 AC adaptor input TOP VIEW 1 Optically isolated INPUT jack 2 Optically isolated OUTPUT jack 3 Non isolated INPUT jack 4 Non isolated OUTPUT jack BUTTON DESCRIPTION 1 Power switch 2 Date Time 3 Function 4 Enter Clear 5 Sample Rate 6 Pause 1 2 3 4 5 6 1 2 3 4 1 2 3 4 ISOLATE DIRECT IN OUT IN OUT TOP VIEW REC OUT AUTO MANUAL 5 ...

Page 3: ...1 407303 Conductivity Meter Dual Direct UPCB 01 407401 Dual Thermometer Dual Direct UPCB 01 407412 Thermo Anemometer Humidity Dual Direct UPCB 01 407428 IR Thermometer Single Direct UPCB 01 407445 RH Temperature Meter Dual Direct UPCB 01 407495 Pressure meter Single Direct UPCB 01 407510 Dissolved Oxygen DO Meter Dual Direct UPCB 01 407768 Sound Level Meter Single Isolated UPCB 02 407777 Moisture ...

Page 4: ...ical value 6 When the desired date and time is programmed the logger will exit the time and date setting function after a few seconds with no button presses Automatic Datalogging This function sets the Datalogger to automatically collect readings at a sample rate set by the user 1 Connect the Dataloggers IN port to the Heavy Duty Meter as shown in the illustration The supplied UPCB 03 cable connec...

Page 5: ...ear NOTE Data will remain in memory until the Datalogger memory is cleared see previous section or until the batteries are removed Manual Datalogging Manual datalogging allows the user to record one reading at a time 1 Turn the Datalogger On 2 Press the Function button until MANUAL is displayed on the LCD 3 Press the PAUSE button to log one measurement Display will change from PS to RC and return ...

Page 6: ...tware from the Windows TM program CD ROM using the instructions provided on the CD ROM The following software screen will appear Software Screen Description 1 COM Port Selection Use pull down menu to select port 2 Data Transfer Status 3 Transferred Data View 4 Data File Name type desired filename 5 Number of readings 6 Instructional steps describing the data transfer process additional steps are l...

Page 7: ...ff the datalogger Data will remain in the datalogger as long as the batteries are fresh The data points are transferred to the file named in step 4 above To view the transferred data click the VIEW DATA button on the software screen Record Format The file stored on the PC can now be opened in other applications such as spreadsheet word processor database or graphics programs Records are comma deli...

Page 8: ...Me and XP Operating Systems Internal Clock Crystal oscillator Memory Non volatile Data is retained at power down Batteries Four 1 5V AA batteries alkaline or heavy duty type Battery life 36 hours continuous typical Power consumption Approx 3 7mA DC Operating temperature 32 to 122 o F 0 to 50 o C Operating humidity 80 RH Weight 0 45 lbs 205g including battery Dimensions 5 2 x 2 8 x 1 0 131 x 70 x 2...

Page 9: ... insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or unauthorized modification Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any di...

Reviews: