background image

Vers. 1.0 / 10.02.21 

 

Ethernet to 4x Serial RS

-

232/422/485

 

with Power over Ethernet Function

 

EX

-

6124PoE

 

Ethernet zu 4x Seriell RS

-

232/422/485 

 

mit Power over Ethernet Funktion

 

Manual

 

Anleitung

 

Summary of Contents for EX-6124PoE

Page 1: ...Vers 1 0 10 02 21 Ethernet to 4x Serial RS 232 422 485 with Power over Ethernet Function EX 6124PoE Ethernet zu 4x Seriell RS 232 422 485 mit Power over Ethernet Funktion Manual Anleitung...

Page 2: ...einigung 14 9 Technische Daten 14 10 Technische Zeichnung 14 Inhaltsverzeichnis Index Copyright 2021 by EXSYS Vertriebs GmbH All Rights Reserved 1 Description 15 2 Extent of Delivery 15 3 Layout Conne...

Page 3: ...iert ohne die Software zu modifizieren Dar ber hinaus k nnen serielle Ger te mit dem Remote Pair Master Slave Modus ber den Peer to Peer Modus miteinander kommunizieren ohne dass ein zwischengeschalte...

Page 4: ...oE LED TXD LED RXD LED Reset Schalter 3 2 Anschl sse LED s DB 9M RS 232 Seriell 9 Pin D SUB Stecker RS 232 Pin Signal Pin Signal Pin Signal 1 DCD 4 DTR 7 RTS 2 RXD 5 GROUND 8 CTS 3 TXD 6 DSR 9 Power V...

Page 5: ...n Blinken Das Ger t ist eingeschaltet 25 30 Sekunden werden ca ben tigt Aus Das Ger t ist ausgeschaltet TXD LED rechts Gr n Blinken Die serielle Schnittstelle sendet Daten Aus Die serielle Schnittstel...

Page 6: ...hergesehene 12V Buchse der EX 6124PoE an Warten Sie etwa 25 30 Sekunden bis die Status LED anf ngt zu blinken Sobald diese LED blinkt ist das Ger t betriebsbereit L cher f r Wandmontage 4 Hardware Ins...

Page 7: ...E auf Werkseinstellung zur cksetzen m chten dann dr cken und hal ten Sie den Reset Schalter f r ca 3 5 Sekunden gedr ckt Die Status LED erlischt und f ngt ein paar Sekunden sp ter wieder an zu blinken...

Page 8: ...mitgelieferte VCOM Admin Utility vspsetup exe installieren Das Installationsprogramm befindet sich auf der im Lieferumfang enthaltenen Treiber CD in folgendem Ordner Wichtig Bitte f hren Sie das Inst...

Page 9: ...ved 6 VCOM Admin Utility 2 Zuordnung der COM Ports Um den virtuellen COM Anschluss zu erstellen und dem seriellen Ger t zuzuordnen klicken Sie auf COM Mapping Add COM OK Um die COM Port Nummer zu nder...

Page 10: ...ollte nun folgender Eintr ge im Ger temanager sichtbar sein 3 ndern der Einstellungen der seriellen Schnittstelle Wenn Sie die Einstellungen der seriel len Schnittstelle auf andere Werte als die Stand...

Page 11: ...ind klicken Sie auf Remote Device Management und dann Doppelklick auf den ausgew hlten Device Server in der Liste Doppelklick Klicken Sie auf Remote Device Management Doppelklick auf das ausgew hlte E...

Page 12: ...Modbus UDP TCP Client als den Standard VCOM Modus ndern m ssen Sie stattdessen den Webbrowser verwenden Um das Web Konfigurationsmen zu ffnen klicken Sie auf Remote Device Management w hlen Sie Devic...

Page 13: ...enden Bild auf Seite 13 Aus der nachfolgenden Tabellen auf Seite 13 k nnen Sie die Einstellung der DIP Schalter entnehmen DIP Schalter f r Port 1 DIP Schalter f r Port 2 DIP Schalter f r Port 3 DIP Sc...

Page 14: ...nsfer Rate 50 bis 921 6 Kbps Baud Rate Anschl sse 4x 9 Pin D SUB serieller Stecker 1x RJ45 Ethernet Anschluss 1x 12V DC Buchse 1x Terminal Block 5 24V Hardwaresystem Ethernet 10 100 Mbit s VCOM Admin...

Page 15: ...r VCOM that perfectly migrates your serial application without modify ing the software In addition serial devices with remote pair master slave mode can communicate with each other via peer to peer mo...

Page 16: ...ncluded Power Supply Power ACT LED PoE LED TXD LED RXD LED Reset Button Back 5 24V T Block for optional Power Supply DB 9M RS 232 Serial 9 Pin D SUB Connector RS 232 Pin Signal Pin Signal Pin Signal 1...

Page 17: ...uired from power up Off The unit is not booted yet TXD LED right Green Blinking The Serial Port is sending out data Off The Serial Port is not sending out any data RXD LED left Green Blinking The Seri...

Page 18: ...0 seconds until the status LED starts to blink As soon as this LED flashes the device is ready for operation Copyright 2021 by EXSYS Vertriebs GmbH All Rights Reserved 4 Hardware Installation Please o...

Page 19: ...ace RS 232 If you want to reset the EX 6124PoE to Factory Settings then press and hold the reset button for approx 3 5 seconds The status LED goes out and starts flashing again a few seconds later Ple...

Page 20: ...e IP address you must install the VCOM Admin Utility vspsetup exe that comes with the device The installation program is located on the driver CD included in the scope of deliv ery in the following fo...

Page 21: ...f COM Ports To create the virtual COM Port and assign it to the serial device click COM Mapping Add COM OK To change the COM Port number click COM Mapping Modify COM Copyright 2021 by EXSYS Vertriebs...

Page 22: ...anager The following entry should now be visible in the device manager 3 Changing the settings of the serial interface If you change the settings of the serial interface to values other than the defau...

Page 23: ...After you are logged in click Remote Device Management and then double click the selected device server in the list double click Click Remote Device Management double click on the selected element in...

Page 24: ...han the default VCOM mode you must use the web browser in stead To open the web configuration menu click Remote Device Management select Device Server Item Open in Browser and enter following credenti...

Page 25: ...ich switch controls which port From the following tables on page 13 you can see the setting of the DIP switches DIP Switch for Port 1 DIP Switch for Port 2 DIP Switch for Port 3 DIP Switch for Port 4...

Page 26: ...to 921 6 Kbps Baud Rate Connectors 4x 9 Pin D SUB serial Connector 1x RJ45 Ethernet Port 1x 12V DC Connector 1x Terminal Block 5 24V Hardware System Ethernet 10 100 Mbit s VCOM Admin Utility Windows X...

Page 27: ......

Page 28: ......

Reviews: