background image

PWM: 

gives the user the possibility to adjust the PWM frequency of the leds (

600Hz/1200Hz/2000Hz

/

4000Hz

/

6000Hz

/

25000Hz

).

FULL POWER CCT:

 sets the colour temperature at maximum output. 

3200K/4200K/5600K/10000K

 

and 

NORMAL

 can be set.

Activate Password Protection

In the menu 

KEY

 the password protection of the fixture is activated or deactivated. If set 

ON

 the

fixture is password protected when started. 30 seconds after the last setting the menu is locked 
again. To be able to make changes in the menu the password 

UP - DOWN - UP - DOWN - ENTER

needs to be typed in.

MENU

PERSON

HSIC

KEY

ON

HSIC

OFF

MENU

Calibration and Whiteadjustment

PERSON

CALIB.C

WHITE

WH.01

2700K

3000K

8000K

WH.12

o
o
o

RGBtoW

R(0 - 255)

G(0 - 255)

B(0 - 255)

****

CALR

OK

o
o
o

WH.02

In the menu 

CALIB.C

 the calibrations and whiteadjustments can be set.

In the submenu 

WHITE

 the preset colour temperatures for the white values are stored.

In the submenu 

RGBtoW

 a custom colour calibration is stored which limits the maximum brightness 

of the colour channels at the DMX value "255".

NOTE:

 The maximum value can be limited to 0. In this case, a colour channel does not respond 

to a sent DMX value, which can be misinterpreted as a device error.

To reset the changes made to the colour temperature presets to factory default, the setting 

CALR 

needs to be confirmed with the default password 

UP - DOWN - UP - DOWN - 

ENTER.

Info Menu

MENU

In the info menu (

INFO

), submenu 

VERS

 the currently installed firmware version is shown.

PERSON

HSIC

INFO

VERS

V01

E-28

Summary of Contents for led22940

Page 1: ...ng Bedienungsanleitung bitte aufbewahren Keep this Manual for later queries nderungen sind ohne Ank ndigung m glich Changes are possible without prior notice Rev 2018 41 31 User Manual Eigenschaften B...

Page 2: ...showtechnic com www focon showtechnic com by Die beiliegenden Bedienhinweise f r Expolite Ger te sind Bestandteil dieser Bedienungs anleitung Lesen Sie diese sorgf ltig bevor Sie das Ger t in Betrieb...

Page 3: ...Lieferumfang Technische Daten Abmessungen Installation Bedienung Steuerung mit DMX512 Delivery Product Information Dimensions Installation Operation Using DMX512 Controller DE D 04 ENG D 05 D 06 D 07...

Page 4: ...e werden vor dem Versand sorgf ltig gepr ft Sollte der Lieferumfang dennoch nicht vollst ndig sein wenden Sie sich bitte umgehend an Ihren Vertriebspartner Anschlusskabel f r Spannungsversorgung Bedie...

Page 5: ...asse Geh use LEDs LED Treiberstrom Abstrahlwinkel Steuerung DMX Kan le Anschl sse 100V 240V AC 50 60Hz 180W 417 x 286 x 260mm 6 6kg Power In Out DMX In Out 0 C 45 C 98 IP 20 Aluminium Strangpresspro l...

Page 6: ...Abmessungen...

Page 7: ...n Reihe D 07 H ngend Das Ger t kann am Halteb gel h ngend montiert werden Ger te m ssen entsprechend der jeweils g ltigen Vorschriften sicher montiert und mit einer zweiten Sicherung gegen Herabfallen...

Page 8: ...X 512 HSIC DMX HSIC SENS HSIC DMMR PERSON ADDRESS HSIC 0 512 HSIC YES PERSON MOTOR HSIC NO PERSON SETTING HSIC DIMMER HSIC CURV HSIC DMX ERROR HSIC SLOCK HSIC ZOOM OFF DIM1 DIM2 DIM3 OFF CURVE1 CURVE2...

Page 9: ...OOM des Scheinwerfers im Stand Alone Betrieb eingestellt MENU D 10 PERSON STATIC Power Mode MENU PERSON SETTING HSIC PERSONALITY UNO DOS STD P HSIC DIMMER ZOOM 0 100 0 100 PERSON POWER MODE HSIC 575W...

Page 10: ...be erneut gesperrt F r nderungen im Men muss dann das Passwort UP DOWN UP DOWN ENTER eingegeben werden DIMMER stellt die gew nschte Dimmkurve zur Simulation eines Halogenleuchtmittels ein OFF DIM1 DIM...

Page 11: ...IVE STUDIO und POWER zu unterscheiden MODE SETTING legt fest ob das Ger t Daten als Master an andere Ger te sendet MASTER oder nicht SELF PWM bietet die M glichkeit die PWM Frequenz des Ger tes anzupa...

Page 12: ...e nderten Funktionen kommen Auf der Website steht das aktuellste Dokument DMX Channels als PDF zum Download zur Verf gung Steuerung mit DMX512 D 13 UNO 1 0 255 Master Dimmer DOS 1 0 255 Master Dimmer...

Page 13: ...D Fresnel WW Expolite devices are carefully checked before shipment If the delivery is not complete please contact your distributor immediately Power connection cable General Information for Expolite...

Page 14: ...tection Housing LEDs LED Current Optics Control DMX Channels Connectors 100V 240V AC 50 60Hz 180W 417 x 286 x 260mm 6 6kg Power In Out DMX In Out 0 C 45 C 98 IP 20 Extruded Aluminium ca 160W 3200K 3 0...

Page 15: ...Dimensions E 22...

Page 16: ...DMX Addr 1 DMX Addr Nx1 1 DMX Addr Nx2 1 E 23 Hanging The xture can be mounted in a hanging position using the mounting bracket Fixture must be safe mounted in accordance with the relevant regulations...

Page 17: ...DMMR PERSON ADDRESS HSIC 0 512 HSIC YES PERSON MOTOR HSIC NO PERSON SETTING HSIC DIMMER HSIC CURV HSIC DMX ERROR HSIC SLOCK HSIC ZOOM OFF DIM1 DIM2 DIM3 OFF CURVE1 CURVE2 CURVE3 SAVE BLACK OFF ON BASE...

Page 18: ...0 255 for RED GREEN BLUE AMBER LIME and ZOOM as well as the strobe value 0 20Hz STROBE MENU E 26 PERSON HSIC ADDRESS D 001 512 HSIC SSP TOUR Tr16 PERSON PERSONALITY PERSON HSIC STAT RED HSIC HSIC HSI...

Page 19: ...settings back to factory default COLOR in this submenu a colour calibration is selected or deactivated When UC is selected the Uniform Colour factory calibration is used which adjusts devices of di e...

Page 20: ...TE WH 01 2700K 3000K 8000K WH 12 o o o RGBtoW R 0 255 G 0 255 B 0 255 CALR OK o o o WH 02 In the menu CALIB C the calibrations and whiteadjustments can be set In the submenu WHITE the preset colour te...

Page 21: ...nnels as PDF le on the website ready to download Using DMX512 Control E 29 1 0 255 Intensity 2 0 255 Hue 3 0 255 Hue Fine 4 0 255 Saturation CCT 0 10 No Function 11 30 2700K 31 50 3000K 51 70 3200K 71...

Page 22: ...89 81 90 R86 91 100 L213 101 110 R377 111 120 R80 121 130 L202 131 140 L328 141 150 R3314 151 160 L101 161 170 L768 171 255 No Function Strobe 0 9 No Function 10 99 Strobe Slow to fast 100 109 No Func...

Page 23: ...L328 141 150 R3314 151 160 L101 161 170 L768 171 255 No Function Colour Macro White 0 10 No Function 11 30 Red 100 Green Up Blue 0 31 50 Red Down Green 100 Blue 0 51 70 Red 0 Green 100 Blue Up 71 90 R...

Page 24: ...Lightning Strobe 180 189 No Function 190 255 Random Strobe 10 0 255 Zoom Auto 0 40 No Function 41 60 Auto 1 61 80 Auto 2 81 100 Auto 3 101 120 Auto 4 121 140 Auto 5 141 160 Auto 6 161 180 Auto 7 181 2...

Page 25: ...e 8 0 255 Blue Fine 9 0 255 Lime 10 0 255 Lime Fine 11 0 255 Amber 12 0 255 Amber Fine Preset Colour 0 10 No Function 11 20 L106 21 30 R05 31 40 L194 41 50 R54 51 60 L019 61 70 R08 71 80 R89 81 90 R86...

Page 26: ...Full Output 196 200 2700K 201 205 3000K 206 210 3200K 211 215 3500K 216 220 4000K 221 225 4200K 226 230 4500K 231 235 5600K 236 240 6000K 241 245 6500K 246 250 7200K 251 255 8000K Strobe 0 9 No Funct...

Page 27: ...18 0 255 Auto Speed Adjustment Dimmer Speed 0 9 No Function 10 29 Off 30 69 Dim1 70 129 Dim2 130 189 Dim3 190 255 Dim4 19 E 35...

Page 28: ...2018 by Focon Showtechnic Vertriebsgesellschaft mbH...

Reviews: