D I A M A N T
Pro
8
Service intervals
ROUTINE MAINTENANCE SCHEDULE
Main components
Part No.
Months (Cycles)
6 (12500)
12 (25000)
18 (37500)
24 (50000)
Boiler
Non suction valve
65000210
Replace
Replace
Base Plate Electrovalve
60000105
Replace
Thermics Sup. Adaptor
1/2 X 1/2
30000200
Check
Replace
Thermics Inf. Adaptor-
1/2X1/2X1/4
30000210
Check
Replace
3/8 Safety Valve
65000100
Check
Check
Brewing group
Electrovalve 220V
60000112
Replace
Shower
75000010
Replace
Replace
Replace
Replace
8mm group head gasket
75000081
Replace
Replace
Replace
Replace
Taps
Steam tap body
15000338
Clean
Replace
Water tap electrovalves
60
60000125
Replace
SmartSteam electrov.
60000120
Replace
Motor-pump
Pump head
60000030
Replace
Retention Valve
65000010
Replace
Pump Bypass
30400055
Replace
Important:
Always conduct the 6 month service intervals without delay to ensure excellent performance of
the machine and to ensure full warranty coverage.