SERVICE PROGRAMMING: TECHNICIAN SETT.
Adjusting the steam boiler level sensor sensitivity
To change the machine’s steam boiler water level sensor probe sensitivity follow the steps below:
1.
Enter the ‘Technician setting’ menu.
2.
When ‘Boiler probe sensitivity’ is shown on the display, press
to go next option and
to go previous option. Setting will be saved when pressed the icon
and text is white.
3.
If you want to go to main screen again press
.
Adjusting the display temperature units (ºC or ºF)
To adjust the temperature units shown on all displays follow the steps below:
1.
Enter the ‘Technician setting’ menu.
2.
When ‘Temp units’ is shown on the display, press
to go next option and
to go previous option. Setting will be saved when pressed the icon
and text is white.
3.
If you want to go to main screen again press
. All settings will be now in the temperature
unit selected.
Adjusting the number of heating groups
To adjust the number of groups that must be temperature controlled follow the steps below:
1.
Enter the ‘Technician setting’ menu.
2.
When ‘Nr heating groups’ is shown on the display, press
to go next option and
to go
previous option. Setting will be saved when pressed the icon
and text is white.
- OFF: Used in single boiler machines.
- 2: Used in 2Gr - 3 Boilers machines.
- 3: Used in 3Gr - 4 Boilers machines.
3.
If you want to go to main screen again press
.
Enabling/disabling SmartTea
To enable or disable the SmartTea option follow the steps below:
1.
Enter the ‘Technician setting’ menu.
2.
When ‘SmartTea’ is shown on the display, press
to go next option and
to go
previous option. Setting will be saved when pressed the icon
and text is white.
- Enabled (As default): Activates the water valve and then the motor-pump after a delay of 0.5s.
- Disabled: Activates only the water valve.
3.
If you want to go to main screen again press
.