background image

- i -

ThinCom PCMCIA

Ethernet - Modem

Adapter

User

==

s Manual

Summary of Contents for ThinCom PCMCIA

Page 1: ...i ThinCom PCMCIA Ethernet Modem Adapter User s Manual...

Page 2: ...n may be reproduced stored in a retrieval or transmitted in any form or by any means mechanically photocopying or recording The information in this publication has been carefully checked and is believ...

Page 3: ...PCMCIA 2 10 software support 7 Installing the PointEnabler Device Driver 9 Installing the PointEnabler Device Driver on an unlisted Host PC 10 Installation Verification 11 Windows 95 Installation for...

Page 4: ...v AT Command for 2400 96 00 and 33 600 14 400 37 APPENDIX B S Register Summary 41 FCC Compliance Statements 45 FCC Part 68 45 FCC Part 15 46 Canadian Department of Communication Compliance Statement 4...

Page 5: ...Services PCMCIA 2 1 and Windows 95 3 years warranty Fax Data Modem Support industrial standard Hayes AT command set Adaptive Dialing Call progress monitoring Data Mode communication speed 33 600 28 80...

Page 6: ...3 Socket Service and Card Service compliant with PCMCIA 2 10 to operate the PC Card PCMCIA slot Normally the device driver is pre installed on the computer from the factory 4 Network operating system...

Page 7: ...ring shipping If any damage is found please notify your dealer immediately for prompt replacement Turn off the computer HARDWARE INSTALLATION GUIDE This section provides you with general information o...

Page 8: ...LLATION GUIDE for DOS Windows 3 XX Install theThinCom s driver with PC Card device driver C Most of the notebook computer manufacturers supply the device driver program to operate the PC Card slot on...

Page 9: ...stall modem and Ethernet card device driver including Novell ODI and Microsoft NDIS network driver Enabler ODI Choose this option to install the Novell s network device driver only NDIS Choose this op...

Page 10: ...he ThinCom card is recognized and configured successfully the screen message will show socket s information card type as modem together with the COM port and interupt request number assigned to the mo...

Page 11: ...d device driver 3 Set Baud Rate Data bits Parity Flow Control and Stop bit parameters to your normally use 4 Enter the terminal mode This will allow you to issue the AT command directly to the modem 5...

Page 12: ...e upon a card insertion and ask you for the software driver diskette 3 Depending on the previous software and hardware installed in your system it may attempt to copy other files from the Windows 95 i...

Page 13: ...enabled at this time and there should be only one such a line displayed In this case double click on the PCMCIA Controller and a dialog box will be displayed as below Please place a check mark next to...

Page 14: ...1 Click on Start Settings Control Panel Modem Diagnostics tab 2 Locate the modem s COM port then highlight it Click on More Info button 3 The Windows 95 will try to communicate with the modem The More...

Page 15: ...WORK Go to Control Panel Network and then install the nescessery network driver for the Windows 95 Also in here all the protocal driver are listed in here Upon next restart of the notebook The system...

Page 16: ...help you with your selection Modem speed Data Fax Choose Or using the following Initialization string 2400 9600 Hayes Smart Modem AT F C1 D2 9600 9600 Hayes V Series AT F C1 D2 K3 S48 7 14 400 14 400...

Page 17: ...connect 4 Baud Rate The speed that the data traveling between the modem and your computer The setting should be four times of your modem speed For example 5 Flow Control Set the flow control between t...

Page 18: ...d between 300 bps and 57 600 bps In direct mode the DTE to modem data rate can only be set to 300 1200 2400 4800 7200 9600 12000 and 14400 bps Each operating mode is explained as the following Normal...

Page 19: ...choice section and the flow control selection If you are having some difficulty connecting to a remote computer change the init string for the modem to use Normal or Direct Mode Some of the remote ac...

Page 20: ...and 5 249 218 of Spectrum Information Technologies Inc Other patent pending FAX OPERATION The Fax Data Modems support Group III Class 1 EIA TIA 578 or Class 2 commands which are part of the AT command...

Page 21: ...SIGN 2 COMxTXSIZE 16 COMxRXSIZE 8 The x is the number of the COM port You must be sure to be running in the enhanced mode You can force windows to go into enhanced mode by starting Windows with the co...

Page 22: ...be set when the test is in progress Remote Digital Loopback Use AT T6 to initialize this test The test is to check the connection fault between a local modem and a remote modem Data is routed from lo...

Page 23: ...M Port I O address and IRQ setting Click on Main Group Control Panel Ports COM x x com port 1 4 Ensure that only one program is using the modem Cannot type AT in terminal mode Check the IRQ setting in...

Page 24: ...ltages The Socket Services driver operates the host controller chip of your computer Card Services provides the interface between the PC Card card and the Sockets Service driver To make sure Card Serv...

Page 25: ...EXE SSDBOOK E XE SVADEM EX E SSVLSI EXE PCMSS EXE SNOTEP V2 SYS Card Services CS EXE PCMCS EXE CTALKCS EXE Resource Initialization Utility CSALLOC E XE PCMRM AN SYS IDE ATA Driver S_IDE EXE or ATADRV...

Page 26: ...ted checksum I2 Report OK I3 Report firmware revision model and interface type I4 Report response programmed by an OEM I5 Report the country code parameter I6 Report modem data pump model and code rev...

Page 27: ...for busy if enabled and dial tone not detected NO ANSWER CONNECT XXXX and ERROR X2 Report basic call progress result codes and connections speeds i e OK CONNECT RING NO CARRIER also for busy if enable...

Page 28: ...TS and XON XOFF flow control L0 Select dial up line operation L1 Select leased line operation M0 Select direct asynchronous mode M1 Select sync connect with async off line command mode M2 Select sync...

Page 29: ...ile in NVRAM profile 1 X0 Select internal timing for the transmit clock X1 Select external timing for the transmit clock X2 Select slave receive timing for the transmit clock Y0 Recall stored profile...

Page 30: ...d mode N1 Select direct mode N2 Select reliable link mode N3 Select auto reliable mode N4 Force LAPM mode N5 Force MNP mode MS Select modulation ECC COMANDS C0 Disable data compression C1 Enable MNP 5...

Page 31: ...tial transmit level of 30 dBm M2 Select initial transmit level of 10 dBm M3 M10 Select initial transmit level of 10 dBm M11 Select initial transmit level of 11 dBm M12 Select initial transmit level of...

Page 32: ...APPENDIX A APPENDIX A 28 CELLULAR COMMANDS C2 Download cellular phone driver I Identify cellular phone driver T6 Indicate status of cellular phone...

Page 33: ...f during dailing receiving carrier and turn speaker on during answering N0 Disable connection data rate control N1 Enable connection data rate control On 0 Go on line P none Select pulse dialing Q0 En...

Page 34: ...lost Tn 0 Terminates test in progress Terminates test in progress 1 1 Local analog Local analog loopback loopback 3 3 Local digital Local digital loopback loopback 4 4 Grants RDL request from remote...

Page 35: ...e fallback character C 0 No data compression 1 MNP 5 data compression control A 0 0 MNP block size Maximum 64 characters Maximum 64 characters 1 1 MNP block size Maximum 128 characters Maximum 128 cha...

Page 36: ...s enabled V 42 Auto reliable Mode If V 42 detection is enabled Jn a LAPM or MNP link can be detected and negotiated otherwise only LAPM will be Jn a LAPM or MNP link can be detected and negotiated oth...

Page 37: ...Enables V 42 Enables V 42 bis for both transmitting and receiving data bis for both transmitting and receiving data On 16 V 42 bis string length range 6 250 Number of charecters Value saved in NVRAM...

Page 38: ...ook go off hook and enter command mode I0 Report product code I1 Report pre computed checksum from ROM I2 Compute checksum and report status I3 Report firmware revision model and interface type I4 Rep...

Page 39: ...1 Allow RLSD to follow the carrier state D0 Interpret DTR ON to OFF transition per Qn D1 Interpret DTR ON to OFF transition per Qn D2 Interpret DTR ON to OFF transition per Qn D3 Interpret DTR ON to O...

Page 40: ...upon power up Zn x Store dial string x to 40 to location n 0 to 19 E0 Disable line quality monitor and auto retrain E1 Enable line quality monitor and auto retrain E2 Enable line quality monitor and f...

Page 41: ...K2 Enable MNP 10 extended services detection only Q0 Disable MNP 10 fallback to 2400 bps V 22 bis 1200 bps V 22 Q1 Enable MNP 10 fallback to 2400 bps V 22 bis 1200 bps V 22 M0 Select initial transmit...

Page 42: ...ult profile is subsequently loaded and may change some of the factory default values The designated default profile can be changed by entering the Yn command where n is one of the two possible user pr...

Page 43: ...Speaker Results Bit Mapped Options 117 75h S23 General Bit Mapped Options 55 37h S24 Sleep Inactivity Timer 0 255 s 0 S25 Delay to DTR Off 0 255 s or 0 01s 5 S26 RTS to CTS Delay 0 255 0 01s 1 S27 Gen...

Page 44: ...ompression Control 13 S48 V 42 Negotiation Control 7 S80 Soft Switch Functions 0 S82 LAPM Break Control 128 40h S86 Call Failure Reason Code 0 255 S91 PSTN Transmit Attenuation Level 0 15 dBm 10 S92 F...

Page 45: ...APPENDIX B 41...

Page 46: ......

Page 47: ...ance notice isn t practical you will be notified as soon as possible You will be advised of your right to file a complaint with the FCC Your telephone company may make changes in its facilities equipm...

Page 48: ...e will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is...

Page 49: ...etup Option then Date to enter the date and time information 2 In your MiniFax Software go to the Configuration Menu and enter all the information into the menu then click the OK button The MiniFax so...

Page 50: ...er should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be made by an authorized Canadian maintenan...

Page 51: ......

Page 52: ......

Page 53: ......

Reviews: