Standards and Approvals
Electromagnetic Compatibility (EMC)
Radiated disturbance test
Class
A
CISPR
22
CISPR 16-2-3
Electrostatic discharge immunity test
8 kV (air electrostatic discharge)
EN 61000-4-2
4 kV (contact electrostatic discharge)
Radiated, radio-frequency,
80 MHz ÷ 1 GHz, 10V/m
EN 61000-4-3
electromagnetic field immunity test
1,4 GHz ÷ 2 GHz, 3 V/m
2 GHz ÷ 2.7 GHz, 1 V/m
Burst immunity test
± 2 KV dc power port
EN 61000-4-4
± 1 KV signal line
Surge immunity test
± 0,5 KV dc power port (line to earth)
EN 61000-4-5
± 0,5 KV dc power port (line to line)
± 1 KV signal line (line to earth)
Immunity to conducted disturbances
inducted by radiofrequency field
0.15 ÷ 80 MHz, 10V
EN 61000-4-6
Power frequency magnetic field
immunity test
Enclosure, 50/60Hz, 30A/m
EN 61000-4-8
Environmental conditions
Operating temperature (surrounding
-20 ÷ +60°C (vertical installation)
EN 60068-2-14
air temperature)
Plug-in modules and USB devices
may limit max temperature to +50°C
Storage temperature
-20 ÷ +70°C
EN 60068-2-1
EN
60068-2-2
EN
60068-2-14
Operating and storage humidity
5 ÷ 85 % RH not-condensing
EN 60068-2-30
Vibrations
5 ÷ 9 Hz, 7 mm
p-p
EN
60068-2-6
9 ÷ 150 Hz, 1 g
Shock
± 50 g, 11 ms, 3 pulses per axis
EN 60068-2-27
Protection class
Front panel IP66, Rear IP20
EN 60529
3 Technical Specifications
Touchscreen technology
Projected capacitive
Back-up battery
3V 50mAh Lithium, rechargeable, not user-replaceable,
model VL2330.
Fuse
Automatic
Serial Port
RS-232, RS-485, RS-422 software configurable
Flash
4GB for eX705, eX707, eX710, 8GB for eX715, eX721
RAM
512MB for eX705, 1GB for eX707, eX710, 2GB for
eX715, eX721
Hardware clock
Clock/Calendar with back-up battery
Accuracy RTC (at 25°C)
<100ppm